1 / 9

vessels PDF | Goel scientific

We are vessels Manufacturer, vessels supplier, vessels provider, vessels in Canada

Goel4
Télécharger la présentation

vessels PDF | Goel scientific

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. R The Transparent Specialist VESSELS In most of the glass plants, vessels are used as reactors, receivers, separators, measuring or feed vessels. Vessels are available in Spherical shape from 5Ltr to 500Ltr. & in cylindrical shape from 5Ltr to 800Ltr capacity. Cylindrical vessels can be supplied with glass jackets too. All the vessels are provided with a bottom outlet for which a suitable valve can be chosen from our range of valves. 21

  2. R VESSELS The Transparent Specialist SPHERICAL VESSEL - GENERAL DATA Nominal Capacity (Ltrs.) 5 10 20 50 100 200 300 500 Maximum Pressure (Bar) 1 0.8 0.7 0.5 0.4 0.3 0.2 0.1 BULB CAPACITY DN Nominal Capacity (Ltrs.) DN2 T L D DN T DN1 B DN2 P DN3 S P DN3 45° 10° 50A 100 100A 200 200A 300 300A 500 5 10 20 50 425 575 650 840 840 950 950 1200 1200 1310 1310 1450 225 285 350 490 490 600 600 750 750 860 860 1000 50 80 100 100 150 150 225 225 300 300 400 450 75 90 100 100 150 150 150 225 250 300 300 250 25 25 25 40 40 40 40 40 40 50 50 50 125 200 200 200 200 200 200 200 200 200 200 200 25 25 25 40 40 40 40 40 40 50 50 50 50 50 50 75 75 75 75 75 75 75 75 75 40 40 40 100 100 100 100 100 100 100 100 150 75 75 75 100 100 100 100 100 100 100 100 165 S D L B DN1 SINGLE NECK SPHERICAL VESSELS Cat. Ref. Nominal Capacity L DN DN VSA5 VSA10 VSA20 VSA50 VSA50A VSA100 VSA100A VSA200 VSA200A VSA300 VSA300A VSA500 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 300 375 450 640 640 750 750 1000 1000 1110 1110 1250 50 80 100 100 150 150 225 225 300 300 400 450 L THREE NECK BOTTOM OUTLET SPHERICAL VESSELS Cat. Ref. Nominal Capacity DN L DN DN1 DN2 DN2 DN1 VSM5 VSM10 VSM20* VSM50* VSM50A VSM100 VSM100A VSM200 VSM200A VSM300 VSM300A VSM500 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 425 575 650 840 840 950 950 1200 1200 1310 1310 1450 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 50 50 50 50 25 25 25 40 40 40 40 40 50 50 50 50 L DN1 22

  3. R VESSELS The Transparent Specialist FOUR NECK BOTTOM OUTLET SPHERICAL VESSELS Cat. Ref. Nominal Capacity DN L DN DN1 DN2 DN3 DN2 DN1 VSPL5 VSPL10 VSPL20 VSPL50 VSPL50A VSPL100 VSPL100A VSPL200 VSPL200A VSPL300 VSPL300A VSPL500 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 425 575 650 840 840 950 950 1200 1200 1310 1310 1450 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 40 50 50 50 25 25 25 40 40 40 40 40 40 50 50 50 40 40 40 100 100 100 100 100 100 100 100 150 DN3 L DN1 FIVE NECK BOTTOM OUTLET SPHERICAL VESSEL Cat. Ref. Nominal Capacity L DN DN1 DN2 DN3 DN3 VSL10 VSL20 VSL50* VSL50A VSL100* VSL100A VSL200* VSL200A VSL300 VSL300A VSL500 VSL5 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 425 575 650 840 840 950 950 1200 1200 1310 1310 1450 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 50 50 50 50 25 25 25 40 40 40 40 40 50 50 50 50 40 40 40 100 100 100 100 100 100 100 100 150 DN DN2 DN2 DN1 DN2 FIVE NECK BOTTOM OUTLETSPHERICAL VESSEL Cat. Ref. Nominal Capacity L DN DN1 DN2 DN3 DN3 VS 10 VS 20 VS 50* VS 50A VS 100* VS 100A VS 200* VS 200A VS 300 VS 300A VS 500 VS 5 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 425 575 650 840 840 950 950 1200 1200 1310 1310 1450 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 40 50 50 50 25 25 25 40 40 40 40 40 40 50 50 50 40 40 40 100 100 100 100 100 100 100 100 150 DN DN2 DN2 DN1 DN3 23 * marked items are available fast.

  4. R VESSELS The Transparent Specialist SPHERICAL VESSELS WITH NOZZLE AT 90° These vessels are used in Circulatory Boiler System and are to be supported on a vessel holder. More nozzles can be provided on the equator on request for special requirements. DN Cat. Ref. Nominal Capacity DN2 L DN DN1 DN2 DN3 VSD5 VSD10 VSD20 VSD50 VSD50A VSD100 VSD100A VSD200 VSD200A VSD300 VSD300A VSD500 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 425 500 575 765 765 875 875 1125 1125 1235 1235 1375 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 40 50 50 50 25 25 25 40 40 40 40 40 40 50 50 50 40 40 40 100 100 100 100 100 100 100 100 150 L DN3 DN1 SPHERICAL RECEIVERS Receivers are provided with builtin Dip Pipe. These are to be supported on a vessel holding ring. DN DN3 DN2 Cat. Ref. Nominal Capacity (100) DN2 (100) DN3 L DN DN1 VR10* VR20* VR50 VRB5* VRB10* VRB20* VRB50 VR5* 5 L 10 L 20 L 50 L 350 425 500 675 25 25 25 40 25 25 25 25 25 25 25 25 o 10 o 10 L 5 L 10 L 20 L 50 L 350 425 500 675 25 25 25 40 25 25 25 25 25 25 25 25 25 25 25 25 DN1 ADDITION VESSELS These vessels are provided with a short bottom outlet. These should be supported on a vessel holder/ holding ring. DN Cat. Ref. Nominal Capacity L DN DN1 VA5 VA10 VA20 VA50 VA50A VA100 VA100A VA200 VA200A VA300 VA300A VA500 5 L 10 L 20 L 50 L 50 L 100 L 100 L 200 L 200 L 300 L 300 L 500 L 375 450 525 715 715 875 875 1125 1125 1235 1235 1375 50 80 100 100 150 150 225 225 300 300 400 450 25 25 25 40 40 40 40 40 40 50 50 50 L DN1 * marked items are available fast. 24

  5. R VESSELS The Transparent Specialist SPHERICAL VESSELS WITH WIDE BOTTOM OUTLET These vessels are generally used to fit immersion exchangers in the bottom. Special heating mantle or bath should be used if used with. DN Cat. Ref. Nominal Capacity DN2 DN2 L DN DN1 DN2 DN3 DN3 VSR50 VSR50A VSR100 VRS100A VSR200 VSR200A VSE50 VSE50A VSE100 VSE100A VSE200 VSE200A 50 L 50 L 100 L 100 L 200 L 200 L 50 L 50 L 100 L 100 L 200 L 200 L 790 790 900 900 1150 1150 840 840 950 950 1200 1200 100 150 150 225 225 300 100 150 150 225 225 300 150 150 150 150 150 150 100 150 150 225 225 300 40 40 40 40 40 40 100 100 100 100 100 100 L DN1 40 40 40 40 40 40 100 100 100 100 100 100 VESSELS WITH BOTTOM OUTLET VALVE SEAT To fit a bottom outlet valve (BAL type) all spherical and cylindrical vessels can be supplied with valve seat in bottom outlet. For this, Add a suffix "/B" to the catalogue reference of a vessel, for e.g. 'VSL50’ should be mentioned as 'VSL50/B'. Notes on use of Spherical vessels. 1. Generally, the centre nozzle, referred as DN in all types of vessels, is used for either stirrer fixing or if stirrer is not fixed, for vapour outlet. 2. The bottom outlet, referred as DN1 in all types is used for drain. However, in type VSR & VSE, it is also used for fixing immersion heat exchanger. 3. The small side nozzles, referred as DN2 in all types, are used (a) to fix thermometer pocket or, (b) to fix dip pipe for liquid inlet or, (c) to fix sparger for gas purging or, (d) to fix vacuum control or vent valve or, (e) for solid addition. DN1 4. The bigger side nozzle, referred as DN3, is used for vapour outlet where stirrer is fixed on centre neck. It can also be used for cleaning in case centre neck is used for vapour outlet. 5. Vessels having long bottom outlet, viz VSM, VSPL, VSL, VS etc, can be supported in a heating mantle of heating bath. However, vessels having short bottom outlet, viz VSD, VR, VA etc. are to be supported on a vessel holder only. In case of vessels upto 20L size, vessel holding rings can be used instead of vessel holder. CYLINDRICAL VESSELS Cylindrical vessels of 50 Litres and above must be supported in a vessel holder. Cat. Ref. Nominal Capacity DN DN DN1 L L1 VZ5/4 VZ10/6 VZ20/9 VZ20/12 VZ50/12 VZ50/16 VZ100/16 VZ100/18 VZ150/16 VZ150/18 VZ200/18 VZ300/24 Note : For graduation required on vessel, additional charges will be applicable. 5 L 10 L 20 L 20 L 50 L 50 L 50 L 100 L 150 L 150 L 200 L 300 L 100 150 225 300 300 400 400 450 400 450 450 600 25 25 25 40 40 40 40 40 40 40 40 50 850 775 750 575 1000 710 1050 900 1450 1225 1500 1340 175 175 175 175 175 175 175 175 175 175 175 175 L L1 DN1 25

  6. R VESSELS The Transparent Specialist CYLINDRICAL VESSEL COVERS Cat. Ref. DN DN1 DN2 L DN1 VZA4 VZA6 VZA9 VZA12 VZA16 VZA18 VZA24 100 150 225 300 400 450 600 40 40 50 80 100 100 100 2x25 2x40 3x25 3x40 3x40 4x40 4x40 200 200 250 250 275 275 300 DN2 DN2 L DN KETTLES Kettles are similar to cylindrical vessels but having a reduced top neck. DN Cat. Ref. Nominal Capacity DN DN1 L L1 d d KZ200 KZ350 Note : For graduation required on kettles, additional charges will be applicable. 200 L 350 L 300 400 40 50 1400 1500 175 175 540 620 L L1 DN1 JACKETED VESSELS For special applications, cylindrical vessels can be supplied with a jacket for heating or cooling. Jacket is sealed to the vessel with Viton 'O' ring and other sealing compositions. The seal prevents high stresses between vessel and jacket by allowing the movement flexibility between two due to thermal expansion. Glass Jackets Glass Jacket can be used for a maximum operating pressure of 0.5 bar and a maximum o operating temperature of 130 C in jacket. The temperature difference between jacket & vessel 0 should not be exceed than120 C DN DN A A DN1 DN1 L1 L1 D1 D2 D1 D2 L B B L L2 DN1 45 L2 DN2 O 45 DN2 O VZD20/12 VZD30/12 VZD50/12/14 1050 875 VZD50/16/20 VZD100/20/24 955 VZD200/24/28 1175 1000 175 Cat. Ref. VZD5/6 VZD10/9 L L1 325 400 450 575 L2 125 125 125 100 175 100 175 175 175 A 75 90 B D1 165 230 315 315 315 415 516 615 D2 215 280 370 370 365 500 600 700 DN 150 225 300 300 300 400 500 600 DN1 DN2 TYPE 25 25 25 25 25 40 25 40 25 40 25 40 25 40 25 40 TYPE-A DN TYPE-B 500 575 625 750 275 340 385 510 - - - - A B B B C C C C A D2 L1 D1 L - - - - 825 650 780 DN1 L2 DN2 TYPE-C JACKETED VESSELS (TRIPLE WALL) Goel is presenting Flexi (Detachable) “Transparent Double Jacketed Vessel” to maintain the leading position in industry by way of developing indigenously newer products with higher value towards their Mission and to cater the customer via innovation. Salient Features - Made from SCHOTT DURAN Vacuum Jacket ensures - Transparent insulation. - Minimum heat loss - Process visibility. - Minimize frost formation for cryogenics operation. Vacuum Jacket & main vessels are detachable ensures - Ease of cleaning. - No breakages due to thermal expansion. - Partial Replacement of any part can be possible to reduce the maintenance cost. DN A DN1 D1 L1 D2 L B DN1 L2 Cat. Ref. VZT5/6/8 VZT10/9/12 700 VZT20/12/14 675 VZT50/16/18 825 L L1 350 420 500 650 L2 175 175 175 175 A 75 90 125 200 B D1 215 315 365 465 D2 275 390 423 523 DN 150 225 300 400 DN1 25 25 25 25 DN2 25 25 40 40 o 620 310 370 368 350 70 DN2 26

  7. R VESSELS The Transparent Specialist DIP PIPES DN Dip pipes are used as liquid inlet for spherical vessels. Cat. Ref. For Vessel DN DN1 d L DP20/1* DP50/1.5* DP100/1.5* DP200/1.5* 20 L 50 L 100 L 200 L 25 40 40 40 25 25 25 25 12 19 19 19 300 400 500 600 L d SHORT DIP PIPES Short dip pipes are used as re-entry tubes for vessels, heat exchangers etc. Cat.Ref. DN DN1 d L L1 DN1 DP1.5/1 DP1.5/1.5 DP2/1 DP2/1.5 DP1/1 25 40 40 50 50 25 25 40 25 40 12 19 19 25 25 100 100 100 100 100 100 100 100 100 100 DN L1 DN L L DP3/1.5 DP4/1 DP4/2 80 100 100 40 25 50 37 25 50 100 100 100 125 150 150 d d GAS SPARGERS DN Gas spargers are used for gas feed/sparging in the vessels. For Vessel No.of Holes Cat.Ref. DN DN1 d L SPG20/1 SPG50/1.5 SPG100/1.5 SPG200/1.5 20 L 50 L 100 L 200 L 25 40 40 40 25 25 25 25 12 19 19 19 300 400 500 600 5x1mm 5x1mm 5x1mm 5x1mm L d THERMOMETER POCKETS DN Cat. Ref. For Vessel DN d L TP20/1* TP50/1.5* TP100/1.5* TP200/1.5* 20 L 50 L 100 L 200 L 25 40 40 40 12 19 19 19 300 400 500 600 L d 27

  8. R VESSELS The Transparent Specialist HEATING MANTLES Heating Mantle is used for electrical heating of cylindrical as well as spherical vessels. Cat.Ref. Vessel Size Supply Volts D L Watts Circuits JMD10 JMD20 JMD50 JMD100 JMD200 JMD5 5 L 10 L 20 L 50 L 100 L 200 L 320 380 485 600 790 920 190 220 285 345 470 530 600 1000 1800 3600 5400 8100 1 2 3 3 3 3 230 230 230 415 415 415 L D HEATING BATHS Heating baths are used for electrical or steam heating of glass vessels. Depending upon the temperature requirements, different types of thermic fluids or water can be used as heating media. Heating baths are provided with a pair of encased heaters with controller box, a coil for passing the steam or cooling water, a cushioned vessel holding ring, a bottom outlet sealing arrangement, a lid and threaded socket type intlets and outlets. Cat.Ref. Vessel Size d L Watts HTA Vessel HTA Coils L SBH20 SBH50 SBH100 SBH200 SBH300 SBH500 20 L 50 L 100 L 200 L 300 L 500 L 480 615 720 900 1150 1385 340 415 535 620 735 880 2x2000 2x3000 2x4500 2x6000 3x6000 4x6000 0.25 0.5 0.7 1 1.85 2.5 0.4 0.6 1 1.5 2.5 4.0 d COOLING BATHS Cooling baths are used for cooling the glass vessel with ice crystals. Cooling Baths are provided with a vessel holding ring, bottom outlet sealing arrangement and a lid. Cat.Ref. BHC20 BHC50 BHC100 BHC200 Vessel Size d L L 20 L 50 L 100 L 200 L 480 615 720 900 340 415 535 620 d VESSEL HOLDERS Vessel holders are made of cast aluminum with a plaster lining shaped to fit the vessel. These are to be supported on 3 jacking bolts. D d Cat.Ref. Vessel Size D d L L VSS10* VSS20* VSS50* VSS100* VSS200 10 L 20 L 50 L 100 L 200 L 265 325 390 410 700 160 230 230 250 400 90 100 100 100 215 28 * marked items are available fast.

  9. R VESSELS VESSEL HOLDING RINGS The Transparent Specialist These metal rings are wrapped with asbestos rope and are to be supported on two jacking bolts. L Cat.Ref. Vessel Size d L VRS2 VRS5* VRS10* VRS20* 2 L 5 L 10 L 20 L 100 150 215 310 15 15 15 15 d DECANTORS Decantation is a process of separation of two immiscible liquids having different densities. When these liquids allowed to settle forms two distinct layers, heavier at bottom and lighter at top. Goel has developed a Decantor which is suitable for continuous decantation. DN7 DN DN6VENT The mixture of liquids is continuously fed in the Decantor at low velocity. This allow sufficient residence time for the formation of separate layers. The light phase liquid is continuously removed from the light phase outlet at the top. The heavy phase liquid enters the dip pipe at lower end and overflow in the discharge pipe and is removed from the bottom. DN5 LIGHT PHASE DN1 L Goel's Decantor provides continuous separation, visual monitoring, and ensure separation even after feed is stopped. DN2 Decantors can be provided with Adjustable overflow valve, (Type B) to adjust the position of interface for different operating situations. DN4 DRAIN DN3 HEAVY PHASE TYPE - A Cat. Ref. SPS20 SPS50 SPS100 SPS200 SPA20 SPA50 SPA100 SPA200 Heavy Phase Outlet DN3 25 25 25 25 25 25 25 25 Light Phase DN7 Nominal Capacity 20 L 50 L 100 L 200 L 20 L 50 L 100 L 200 L Inlet DrainOutlet Vent DN4 DN5 25 25 25 40 25 40 25 40 25 25 25 40 25 40 25 40 DN L DN DN1 DN2 80 25 100 40 150 40 225 40 80 25 100 40 150 40 225 40 DN6 DN7 Type 25 50 40 50 40 50 40 50 25 50 40 80 40 80 40 80 VENT 800 1025 1175 1475 1000 1225 1375 1675 50 50 50 50 50 50 50 50 A A A A DN5 DN6 LIGHT PHASE L DN1 B B B B DN2 DN4 DRAIN DN3 HEAVY PHASE Decantors can also be constructed with horizontal cylindrical vessels (Cat.ref. HPS or HPA) to provide larger separating surface. TYPE - B HPS HPA 29

More Related