The ME950 Frequently asked Questions. Professional Development Department Lisa Berkeley, M.A., CCC-A. The ME950 Frequently asked Questions. Professional Development Department Rebecca A. Younk, M.S., CCC-A. Telecoils.

Leo
Télécharger la présentation

The ME950 Frequently asked Questions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The ME950Frequently asked Questions Professional Development Department Lisa Berkeley, M.A., CCC-A

  2. The ME950Frequently asked Questions Professional Development Department Rebecca A. Younk, M.S., CCC-A

  3. Telecoils • Telecoils are inductive coils put inside hearing instruments to pick up electromagnetic leakage from telephone receivers

  4. Telecoils • When the aid has a telecoil, the patient is able to hear what is being said on the other end of the phone • Telecoils cannot be put into every size hearing aid, space is the limiting factor • The phone must be “hearing aid compatible” for the telecoil to work

  5. Telecoils • It is not new technology • Telecoils have been around for 50 years • The only new component is the “switchless” feature

  6. Switchless Telecoils Same component, different path • Everyone has a different name for the same feature (AutoPhone, Easy T, Auto Telecoil) • The hearing aid will switch to the telecoil program automatically when a HA compatible phone is used

  7. ME950 AutoPhone • An automatic telephone detection with no manual adjustments required • With AutoPhone, ME950 automatically switches to • Telecoil or • Acoustic telephone

  8. ME950 AutoPhone • AutoPhone can be activated • BTEs – in Program 2 or Program 3 • AutoPhone can be switched off if desired • Available in all BTEs

  9. Data Recall with the Smart VC

  10. Current Solutions • Instruments are fitted in a quiet clinic, away from real-life environments • Fittings are done using a prescription based on averages • Fine-tuning is very often done with “unnatural” signals • Fine-tuning is challenging within the time constraints of clinical appointments • The fitter does not know the individual loudness preferences

  11. Smart VC • Data Recall analyzes the volume adjustments made by the wearer in each program (via volume control and/or remote) • The changes are weighted, averaged and automatically applied for each listening program • Most recent volume changes have a larger effect on the learning result

  12. Data Recall – Technical Details Smart VC – The principle 12 8 4 0 VC position -4 -8 -12 -16 1 2 3 4 5 6 7 Time in days Manual VC changes (arrows), current VC position (grey line segments) and learning curve of Smart VC (blue)National Acoustics Laboratory, Australia – IPS patient study

  13. Volume Control Basics • VC range – the total amount of gain that a VC has from “just-on” to full-on • Power on position will default to 48% • If this needs to be changed, you must uncheck the SmartVC VC range = 16 48% 8 dB 8 dB

  14. Data Recall – Technical Details

  15. Data Recall – Fitting information • Data Recall can be accessed from the tool bar, menu or from program selection • Maximum learning range is +/- 12 dB

  16. The bi-directional remote control • Controls and reads instrument settings • This is the same remote that is available for the ME900

  17. Wax Guard Systems

  18. What is Preferred? Wax trap Extended Receiver Tube Wax Spring

  19. Informal Poll Results

  20. Available C-Guard (950 only) Disposable Wax Guard Wax Spring Discontinued Wax Guard Wax Trap Wax Guard System

  21. C-Guard wax protection solution • Standard on all ME950 custom instruments • Effectively seals the receiver with a membrane barrier • Is ONLY available on the ME950 custom products

  22. BTE instruments – Color optionsThey‘re not just for open BTEs Beige Grey Brown