1 / 13

Ultima ® XL/XT Gas Monitors Providing HART and 4-20mA output

Ultima ® XL/XT Gas Monitors Providing HART and 4-20mA output. Ultima XL / XT Gas Monitors. HART: General Information Network Topology Ultima XL/XT Features Calibration Options Approvals Sales Support . HART – General Information. HART (Highway Addressable Remote Transducer)

Melvin
Télécharger la présentation

Ultima ® XL/XT Gas Monitors Providing HART and 4-20mA output

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ultima® XL/XT Gas MonitorsProviding HART and 4-20mA output

  2. Ultima XL / XT Gas Monitors • HART: • General Information • Network Topology • Ultima XL/XT Features • Calibration Options • Approvals • Sales Support

  3. HART – General Information • HART (Highway Addressable Remote Transducer) • MSA device is a slave in a polled network • HART is a software protocol running over 4-20mA Hardware • Point to point • 1200 baud FSK

  4. HART – General Information con’t • HART Communication is a bi-directional industrial field communication protocol used to communicate between intelligent field instruments and host systems. • HART provides two simultaneous communication channels: the 4-20mA analog signal and a digital signal. The 4-20mA signal communicates the primary measured value (in the case of a field instrument) using the 4-20mA current loop - the fastest and most reliable industry standard. Additional device information is communicated using a digital signal that is superimposed on the analog signal. The digital signal contains information from the device including device status, diagnostics, additional measured or calculated values, etc. Together, the two communication channels provide a complete field communication solution that is easy to use and configure, is low-cost and is very robust. Visit www.hartcomm2.org for more information

  5. Typical HART Network Topology

  6. Ultima XL/XT Features • Non-display versions of XE & XA • Single sensor gas monitor • Enclosure options • Stainless steel - XL • Polycarbonate G.P. - XT • Condulet has openings for: • Sensor entry • Intrinsically Safe HART Port (optional) • Signal and Power Wiring • Internal Push-button & LEDs for Calibration • Available in Remote Condulet Versions

  7. Ultima XL/XT Features Main board configuration • Similar to the UltimaX main board • Single removable design with standoffs • No tools required for insertion into the condulet

  8. Ultima XL/XT Calibration Options • Calibration utilizing: • Internal push-button and LEDs (intrusive) • Portable handheld communicator, host DCS or laptop • Disconnect under power (in-shop calibration) • Sensor X-change program

  9. Ultima XL/XT Local Calibration • Utilizes internal push-button & LEDs to perform local calibration without the need of the HART communicator.

  10. FM Approvals Globally • US/Canada • Class I Div 1&2 Groups A,B,C,D • Class I Zone 1&2 Groups IIC, IIB, IIA, T6 • Type 4X, IP 66 • Europe • ATEX II 2G 3G EEx d nA [ib] IIC T6 • IP 66 • International • IEC Ex d nA [ib] IIC T6 • IP 66

  11. Sales Support • Customer requirements • HART handheld controller • Must be compatible with the Emerson 375 • Emerson 275 will NOT work • HART Rev 6 or Rev 7 • Latest DD’s downloaded to handheld controller • A Device Description (DD) is an electronic data file prepared in accordance with Device Description Language specifications that describes specific features and functions of a device including details of menus and graphic display features to be used by host applications (including handheld devices) to access all parameters and data in the corresponding device. • Download from Emerson website (or other handheld controller that subscribes to the HART foundation updates) • Through HART membership www.hartcomm2.org • Available from MSA

  12. Sales Support • Before customer visit • Ensure customer has latest downloads to their handheld • Ask customer to bring handheld and connector cable to meeting • Bring power supply from XE demo kit Demo Ultima XL/XT during sales call!

  13. Detailed device information 4-20 output calibration Alarm set points Calibration HART handheld menu tree

More Related