An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Chem. 230 9/14 Lecture

    2. Announcements Homework set 1 Short Answer Solutions Posted Long Problems Due Solutions to Long Problems to be Posted Soon Sign up for Presentation Project Available Can sign up at break or end of class Can also sign up next time Can ask to do your own topic, but will need permission (so choose back up topic too)

    3. Announcements First Quiz First 30 minutes next Wednesday Will cover materials on Simple Extractions (in text and covered in lecture) Questions will be similar to those given as examples in lecture and in homework You should be familiar with equations needed, but constants will be provided

    4. Liquid-Liquid Extractions One More Question Benzylamine (C6H5CH2NH2) is a weak base with a Kow of 12. The conjugate acid of benzylamine has a pKa of 9.35. Benzylamine is being extracted from 10 mL of water buffered to a pH of 8.00 (raffinate phase) to octanol. (assume no other reactions occur in water or octanol) Determine the distribution coefficient. Calculate the fraction of benzylamine extracted into octanol if 20 mL of octanol is used? How could Q be increased?

    5. Advanced Extraction Techniques Solid Phase Extraction Solid Phase Extraction (SPE) is most commonly used in place of liquid-liquid extraction but similar methods are used to trap gases also (as shown in purge and trap GC) Can be use for contaminant removal, analyte trapping, or 2D separation (though limited to less than ~ 5 fractions) Types of solid phases are similar to stationary phases used in HPLC

    6. Advanced Extraction Techniques SPE Demonstration Procedure: Clean cartridge with removing solvent, then sample solvent Apply sample; strongly retained compounds will remain on stationary phase, weakly retained/unretained compounds pass through Rinse cartridge with sample solvent Apply eluting solvent to remove strongly retained compounds It is possible to Increase solvent strength to remove compounds in several fractions

    7. Advanced Extraction Techniques SPE Demonstration Example: Mixture of methylene blue (organic cation) and I2 in 90% water 10% methanol Could in theory separate using either C18 or cation-exchange solid phase C18 used in example (and methylene blue is a sticky molecule so sticks to many surfaces, though should pass through C18 column)

    8. Advanced Extraction Techniques Solid Phase Extraction Solid Phase Very Similar to HPLC packing particles Smaller column Larger particles (allowing low pressure elution) Some Types Silica Based (octadecyl or C18, phenyl, aminopropyl, etc.) Ion Exchange (normally charged group on polymeric solid) Others (e.g. graphitic carbon)

    9. Advanced Extraction Techniques Solid Phase Extraction Partitioning Strategies As before, both efficient phase transfer and good selectivity are desired To trap less polar compounds in polar solvents, hydrophobic stationary phases (also known as reversed-phase) are desired. (Example: pesticides in water) To trap more polar compounds in less polar solvents, hydrophillic stationary phases (also known as normal phase) are desired. (Example: sugars in acetonitrile, steroids in hexane) Trapping of polar compounds in polar solvents (or non-polar compounds in non-polar solvents) is difficult. Breakthrough often occurs. Larger analyte solvent polarity difference allows better trapping but is limited by analyte solubility. To trap ionic compounds (usually in water), stationary phases with charged groups opposite in charge to analyte ions are used. It may be possible to produce several fractions by increasing solvent strength or changing pH.

    10. Advanced Extraction Techniques Solid Phase Extraction Reversed-Phase Groups C18 (most commonly used); best for trapping compounds with alkyl groups Phenyl: good for enhanced retention of aromatic compounds Stronger solvent is less polar Normal-Phase Groups Cyano (-CN) Amino (-NH2) Hydroxy (diol or SiOH) Stronger solvent is more polar

    11. Advanced Extraction Techniques Solid Phase Extraction Ion Exchange Stationary Phases Sulfonate groups common for cation exchange Ammonium groups NR3+ common for anion exchange Trapping occurs in low ionic strength solvents; release occurs in high ionic strength Weak acids/bases need to be trapped in ion form but also can be released by pH adjustment

    12. Advanced Extraction Techniques SPE - Questions It is desired to trap benzoic acid in an aqueous phase on an SPE cartridge and release it to an aqueous phase. Is this possible? Fish triglyerides are extracted in hexane. Describe a way to separate the triglyerides from more polar compounds (free fatty acids and steroids with OH groups). Trapping of trace amounts of phenols in water is attempted. To concentrate phenols, large volumes of water are used followed by small volumes of acetonitrile. What is a concern? Some of the phenols in water contain carboxylic acids. Suggest a way to trap both carboxylic acid-containing phenols and regular phenols while releasing them into two fractions for separate analysis. The pKa for carboxylic acids are about 4 and about 10 for phenols.

    13. Advanced Extraction Techniques Solid Phase Micro Extraction (SPME) Can be used for subsequent analysis by GC or HPLC, but most common with GC Typically, non-exhaustive type sampling (meaning only a portion of analyte in sample is trapped). Quantitation is based on keeping exposure to samples the same. While quantitation is often difficult, sensitivity is enhanced relative to SPE because whole trapped sample is injected.

    14. Advanced Extraction Techniques SPME Procedure The needle pierces the septum to a sample (sample can be gas, liquid, or headspace) The sheath is removed allowing trapping of analytes on fiber Stirring helps the transfer The sheath goes back and the needle is withdrawn The needle pierces the septum to a GC, the sheath is withdrawn and the analyte is desorbed by the heated GC injector

    15. Advanced Extraction Techniques SPME Advantages/Disadvantages Advantages: Listed as Solvent-less technique (at least great reduction in solvent injected into GC) Less interference from solvent peak No injection of non-volatiles Less sample handling (+ ability to automate) Can chose fibers for good selectivity Disadvantages: More difficult for quantitative results Limited lifetime of fibers Memory Effects (slow desorption from fibers)

    16. Advanced Extraction Techniques Other Methods Emphasis toward microscale methods Liquid-Liquid Microextraction (drop scale liquid liquid extraction) Use of semi-permeable membranes (discussed in text) Stir-Bar Sorptive Extraction

    17. Advanced Extraction Techniques Some Questions A test for decomposition of a milk sample is made by measuring small aldehydes (e.g. butyraldehyde) by SPME through direct immersion in milk. A non-polar fiber is used and analysis is performed by GC with a non-polar stationary phase. Which of the following are advantages of using the SPME method: removal of interferents (other parts to milk) 2 dimensions of separation (on SPME fiber and on GC column) increase of concentrations by trapping on fiber avoiding need for more labor intensive methods (e.g. liquid liquid extraction) If a fiber is let sit in a solution long enough, the peak area will reach a constant (be independent of time). Why is this? Is this exhaustive extraction? In SPME for HPLC, analytes are desorbed from the fiber into solvent that is injected into the HPLC column. Should the solvent be stronger or weaker than the sample solvent? In comparing direct headspace injections with SPME headspace injections, later eluting peaks are larger in SPME. Explain why.

    18. Chromatographic Theory Simple Separations vs. Chromatography Simple separations generally involve one to several process steps that lead to two to several fractions. Simple separations are limited to coarse fractionation of samples. Chromatographic separations are generally capable of isolating more than 5 compounds. Once the number of simple separation steps goes over a few (maybe 5 maximum), it becomes a labor inefficient way of performing a separation.

    19. Chromatographic Theory Simple Separations vs. Chromatography Example of separation of two compounds by LLE. Compound X has Kp = 0.25 and Compound Y has Kp = 4. Extraction of X and Y using n washes with extractant phase (equal volumes and saving all extractant phase) To get efficient transfer of X means transferring a fair amount of Y also (poor selectivity)

    20. Chromatographic Theory Simple Separations vs. Chromatography Continuation of example Better selectivity at same efficiency can be made by adjusting extract volume and increasing number of extractions In past example, using Vraf/Vext = 2.5/1 with 5 extractions results in 99% efficient transfer of X, while only transferring 38% Y Table shows dependence of %Y transferred on Kp values (assuming Kp(Y) = 1/Kp(X)) and 99% transfer of Y with 3 extractions (volumes adjusted to get ~99% transfer of X)

    21. Chromatographic Theory Simple Separations vs. Chromatography Chromatography example Even column of poor efficiency can handle much more similar compounds Example: KY/KX = 1.25 (= a value) If we assume kX = 4, and resolution = 1.5 (minimum for baseline), a plate number of ~1000 would be needed (not very high)

    22. Chromatographic Theory Simple Separations vs. Chromatography Conclusions to example: Unless order of magnitude differences in Kp values, simple separations have limited use (e.g. reduction of interfering substance). Simple separations are better for coarse separations Chromatographic separations can handle similar K values much better.

    23. Chromatographic Theory Chromatography vs. Other Advanced Separation Techniques Chromatography is based on analyte partitioning between two phases Other methods use different mechanism for separation of analytes (e.g. electrolytic mobility in capillary zone electrophoresis) Some areas of overlap (e.g. Capillary electrochromatography and size exclusion chromatography)

    24. Chromatographic Theory Phase Definitions Mobile Phase (M subscript in later parameters) Fluid phase (gas, liquid or supercritical fluid) that moves through stationary phase Mobile phase defines the major classes of chromatography (GC, LC and SFC) Stationary Phase (S subscript) A non-moving phase (except in MEKC) to which compounds partition via absorption or adsorption Phase can be liquid (not very stable), liquid-like (most common), or solid (common for some applications) In past was second part of class name (for example GLC for gas-liquid chromatography)

    25. Chromatographic Theory More on Stationary Phases Stationary phases come in several arrangements: in columns or on plates (used in thin layer chromatography) In columns, open tubular (coated walls), packed columns and monoliths are possible means of attaching stationary phase Packed columns contain packing material with the stationary phase either being the surface or being a coating on the surface Porous packing material is common Most common stationary phase is a liquid-like material chemically bonded to packing material or to wall (in open tubular chromatography).

    26. Chromatographic Theory More on Stationary Phases

    27. Chromatographic Theory Definition Section Chromatograph = instrument Chromatogram = detection vs. time (vol.) plot