1 / 16

Limiting Oxygen Concentration (LOC) Work Update

Limiting Oxygen Concentration (LOC) Work Update. Steve Summer Project Engineer Federal Aviation Administration Fire Safety Branch, AAR-440. International Aircraft Systems Fire Protection Working Group Atlantic City, NJ November 5 - 6, 2003. LOC Testing – Work Update.

Pat_Xavi
Télécharger la présentation

Limiting Oxygen Concentration (LOC) Work Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Limiting Oxygen Concentration (LOC) Work Update Steve Summer Project Engineer Federal Aviation Administration Fire Safety Branch, AAR-440 International Aircraft Systems Fire Protection Working Group Atlantic City, NJ November 5 - 6, 2003 IASFPWG – Atlantic City, NJ

  2. LOC Testing – Work Update • Technical Note consisting of all data except 400 cycle short tests published and placed on website (AR-02/79) • 400 cycle short spark energy has been measured and testing has been completed • Final report currently being put together IASFPWG – Atlantic City, NJ

  3. Facilities – Pressure Chamber IASFPWG – Atlantic City, NJ

  4. Facilities – Pressure Chamber • 353 ft3 pressure vessel • Working pressure of 650 psi. • Attached vacuum pump used to evacuate chamber to reduced pressures seen at altitude. • Not capable of simulating temperatures seen at altitude. IASFPWG – Atlantic City, NJ

  5. Facilities - LOC Test Article • 9 ft3 simulated fuel tank placed inside of vessel equipped with: • Bottom surface heaters. • 12 thermocouples. • 2 piezoresistive pressure transducers mounted behind sintered porous metal discs. • Interchangeable pressure relief mechanism. • ¼-in. aluminum plate. • Foil diaphragm. • Spark gap. • 2 tungsten electrodes with controllable gap alignment and spacing IASFPWG – Atlantic City, NJ

  6. Apparatus – LOC Testing IASFPWG – Atlantic City, NJ

  7. Apparatus – LOC Testing IASFPWG – Atlantic City, NJ

  8. Ullage Vapor Sampling IASFPWG – Atlantic City, NJ

  9. LOC Testing Apparatus • Ignition Sources • 10 kV Oil burner transformer operating at ~30 mA provided both long (~1 second) and short (~0.1 second) arcs • J-57 Engine spark igniter provided a very short (~175 msecond) spark • 3" x 6" x 1" metal block heated by two cartridge heaters to temperature in excess of 1400°F • 400 cycle, 120 V hard short to ground provided high energy/current, short duration spark • Energy Measurements • Voltage and current traces were taken using a HV and current probe at the spark gap connected to oscilloscope IASFPWG – Atlantic City, NJ

  10. Test Program • JP-8 LOC Tests • Mass Loading ~ 4.5 kg/m3 • Ambient pressure corresponding to altitudes of 0, 10, 20, 30 and 38 kft • Ullage oxygen concentrations ranging from 21% to below the determined LOC • Tests conducted with two different pressure relief mechanisms • ¼-in. aluminum plate • Ignition = movement of plate • Foil diaphragm • Ignition = rupture of foil IASFPWG – Atlantic City, NJ

  11. Test Program (cont.) • Tests conducted initially at all altitudes with long duration oil burner transformer arc (~0.5 J, 1 s) • Subsequent tests conducted with various ignition sources at sea level in effort to determine any variation of LOC with ignition source • Short duration oil burner transformer arc (~0.08 J, 0.1 s) • J-57 Engine igniter spark (~0.5 J, 175 ms) • Hot surface vapor ignition (HSVI) • 400 cycle, 120 V hard short to ground IASFPWG – Atlantic City, NJ

  12. IASFPWG – Atlantic City, NJ

  13. 400 Cycle Hard Short Tests IASFPWG – Atlantic City, NJ

  14. Spark Energy Measurements Energy ~ 2.8 J Duration ~ .01 s Energy ~ 2.2 J Duration ~ .006 s Energy ~ 1.75 J Duration ~ .01 s IASFPWG – Atlantic City, NJ

  15. 400 Cycle Short Test Results IASFPWG – Atlantic City, NJ

  16. Summary • ~2 J spark from 400 cycle short did not cause a change in the LOC at sea level • Of all ignition sources used (oil burner arc, engine ignitor spark, hot surface, 400 cycle short), none have caused an ignition with ullage above 12% O2 • Testing is complete and final report will be published and available on website ASAP IASFPWG – Atlantic City, NJ