1 / 10

Automatic Sprinkler Fire Protection Research Council

Council Mission and Membership. Mission - To enhance the design and installation of fire sprinkler systems through research and education in support of NFPA 13Reporting Structure - A subdivision of the Fire Protection Research Foundation

Sophia
Télécharger la présentation

Automatic Sprinkler Fire Protection Research Council

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Automatic Sprinkler Fire Protection Research Council Fire Protection Research Foundation September 22, 2008

    2. Council Mission and Membership Mission - To enhance the design and installation of fire sprinkler systems through research and education in support of NFPA 13 Reporting Structure - A subdivision of the Fire Protection Research Foundation Membership - The Council is open to all individuals who support its mission; liaison with Foundation Board and NFPA staff and NFPA 13 Technical Committees. Chair and vice chair elected by the Council.

    3. Council Activities Plan, oversee and communicate research in support of its mission Research agenda development Resource for project sponsors, technical panel members Symposia planning Yearly meetings; regular email communications

    4. Automatic Sprinkler Research at the Foundation Compact Shelf Storage Protection Solid Shelf Storage Protection HVLS Fans and Sprinkler Interaction Home Fire Sprinkler Cost Assessments ------------- Foam Water Sprinkler Storage Protection Sprinkler Vent Curtain Interaction ESFR Sprinkler Protection

    5. Topics? Short term issues that will likely arise in the next cycle Longer term design basis Longer term/strategic changes in storage configurations and contents, environmental restrictions on water/foams

    6. Council Recommendations - Special Subjects Seismic Performance Of Pipe Drops In Sprinkler Systems - 3 High Rise water supply and Fire Pump Reliability time sensitive (NIST recommendations) -1 Impact Of NFPA 25 Enforcement - reference the Australian experience -1 Antifreeze Impact on Density (NEW -Huggins) Ceiling Pockets (NEW Huggins) Seismic requirements for 5% drift limits in rack storage NEW Thacker - 3

    7. Council Recommendations General Storage - 5 Storage Occupancies with Standard Spray Sprinklers /Validate Existing Class III and Class IV Storage Curves for large K-factor sprinklers - 3 Expanded Group A Plastic in Rack Storage - 13 Storage Under Sloped Ceilings - 9 Storage Fire Protection and Final Extinguishment (NEW Zurich NA) 13E, FF tactics, mop up training, impact on storage design, consider vents - 11 Pallets geometries , woods FM is doing it now NEW Golinveaux - 2 Burning characteristics of commodities related to protection/full scale performance, classification include pallet issues, geometry effects NEW Golinveaux - 7

    8. Council Recommendations - Special Applications Indoor Boat Storage Protection Requirements Phase II - 1 Indoor RV storage Indoor Storage of PODs - 2 Protection Of Oxidizers Active Fire Protection In Tunnels Utilization of Pre-action ESFR Systems For Cold Storage Occupancies Sidewall Sprinklers For Balconies - NFSA doing some work now Ceiling pockets - 1 Sprinklers for small commercial bldg risk assessment, special requirements , 13S- 3 Lightweight construction sprinkler impact on safety NEW Golinveaux - 1 Performance of Dry Pipe Systems for Common Light/Ordinary Hazard Type Sprinkler Scenarios

    9. Council Recommendations - Residential - 6 Single Sprinkler - field and lab studies, performance objectives, test methods, note ceiling geometry, hazard assessment /Water Meter Effects on Residential Flow - education on the water issue together with AWWA/Fire Flow Design Calculations and Fire Protection Requirements - 21 Costs study thresholds NEW Franson Municipal water usage sprinkler actuation vs fire department response

    10. Council Recommendations - Design/Modeling - 1 Sprinkler Performance Reliability start with literature review /Sprinkler - 3Performance and Trade-Offs (NEW - SP) - 1 Sprinkler/Smoke Management Interface - 2 Technical Basis for Integrating Fire Suppression and Risk/Hazard Model Validation How Is A Fire Plume Affected By Sprinkler Water Spray? - UMD work with Andre Marshall - 2