BORRI Company and Products 2012

BORRI Company and Products 2012. Developments and Achievements. Borri Manufacturing. New manufacturing plant Total of 3 factories in Arrezo New client test area New FXS firmware development. Developments and Achievements. Borri UK growth and structure.

acacia
Télécharger la présentation

BORRI Company and Products 2012

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BORRI Company and Products 2012

  2. Developments and Achievements Borri Manufacturing • New manufacturing plant • Total of 3 factories in Arrezo • New client test area • New FXS firmware development

  3. Developments and Achievements Borri UK growth and structure • Electrical installation 2 man division • New DC installation team. 2 teams 4 engineers total. • Investment in service support desk. 2 office based first line support engineers. 2 in house service and support engineers • Additional UPS site engineers. 11 Borri field UPS engineers.

  4. Developments and Achievements Efficiency and Carbon Trust • Carbon Trust ETL accreditation up to 6.4MVA • FXS firmware in development to 99% target efficiency • B8000 target accreditation up to 100kVA

  5. Developments and Achievements Marketing • 6 Publications per month • Multiple case studies • Data Centre world February 2012 • Comms Expo • Netcoms • Data Centre Dynamics

  6. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B60 B200 B400 Rotation B500 B500 EVO B8000 B9000 B9600 800VA to 2000VA Stepwave 1kVA to 2kVA Sinewave 1kVA to 3kVA Double Conversion 1kVA to 10kVA Rack / Tower Double Conversion 6kVA to 10kVA Double Conversion 1/1p 10kVA to 20kVA Double Conversion 1/1p or 3/1p 10kVA to 40kVA Double Conversion 3/3p IGBT ECO 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO

  7. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B60 B200 800VA to 2000VA Stepwave 1000kVA to 2kVA Sinewave • Line Interactive • Simulated Sine Wave B60 • Pure Sinewave B200 • AVR • LCD Display • USB Connectivity • Intelligent Shutdown and Monitoring

  8. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion • Online Double Conversion • Eco Mode selectable • 110V-300V Input Tolerance • <5% THDi • 208 / 220 / 230V Output Selectable • 0.8 p.f Output Power Factor • 50/60Hz Output (Frequency Converter) • EPO • Twin communication interface • Thyristor STS

  9. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion

  10. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion Cover 1kVA Standard model rear panel USB Standard EPO Retention Clip (Only for output sockets)

  11. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion Battery connector (3P Anderson) 1kVA charger model rear panel Retention Clip (Only for output sockets)

  12. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion 2kVA Standard model rear panel Cover Retention Clip (Only for output sockets) Input socket 10A

  13. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion 2kVA charger model rear panel Battery connector (6P Anderson) Retention Clip (Only for output sockets) Input socket 16A

  14. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion Cover 3kVA standard model rear panel Retention Clips (Only for output sockets) Input Socket 16A

  15. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 1kVA to 3kVA Double Conversion Battery connector (6P Anderson) 3kVA charger model rear panel Retention Clips (Only for output sockets) Tower B400 3kVA UPS Output sockets scaled

  16. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 6kVA to 10kVA Double Conversion 1/1p

  17. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 6kVA to 10kVA Double Conversion 1/1p • Online Double Conversion • Eco Mode selectable • 110V-300V Input Tolerance • <5% THDi • Inverter Interlock • 208 / 220 / 230V Output Selectable • 0.9 p.f Output Power Factor • 50/60Hz Output (Frequency Converter) • EPO • Up to 4 units parallel • Interactive Display • Programmable Relay (Standard) • Internal batteries • Twin communication interface • Thyristor STS

  18. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 6kVA to 10kVA Double Conversion 1/1p

  19. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 6kVA to 10kVA Double Conversion 1/1p Dry in / EPO Dry out Battery Connector for 6K/6KS, 10K/10KS (6P Anderson) Terminal Block Scaled (uncovered) 10K/10KS

  20. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 Evo 10kVA, 15kVA & 20kVA Double Conversion 1/1p or 3/1p • 1/1 or 3/1 Selectable • Online Double Conversion • Eco Mode selectable • Inverter Interlock • 110V-276V Input Tolerance • <5% THDi • 208 / 208 / 220 / 230V Output Selectable • 0.9 p.f Output Power Factor • 50/60Hz Output (Frequency Converter) • EPO • Up to 4 units parallel • Interactive Display • Programmable Relay (Standard) • Internal batteries 10kVA, 15kVA and 20kVA • Thyristor STS

  21. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 Evo 10kVA, 15kVA & 20kVA Double Conversion 1/1p or 3/1p

  22. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B500 Evo 10kVA, 15kVA & 20kVA Double Conversion 1/1p or 3/1p The AS400 has dry function Terminal block Scaled (uncovered) 20K/20KS

  23. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B400 B500 B500 EVO 1kVA to 3kVA Double Conversion 6kVA to 10kVA Double Conversion 1/1p 10kVA to 20kVA Double Conversion 1/1p or 3/1p • USB Standard • EPO Standard • Dry Contact. Single programmable relay for B500 standard • Dry Contact (AS400) Hardwired Optional • Dry Contact (AS400) DB9 Optional • SNMP Optional • Modbus Optional

  24. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 Rotation 1kVA to 3kVA Rack / Tower Double Conversion • Online Double Conversion • Rack / Tower Design • 2 U Height, compact design • 0.8 output power factor • DSP Control • Wide Input Tolerance • <7% THDi • 0.98 input Pf • 208 / 220 / 230V Output Selectable • 50/60Hz auto sensing • Cost effective long runtimes

  25. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 Rotation 6kVA and 10 kVA Rack / Tower Double Conversion • Online Double Conversion • Rack / Tower Design • Parallel up to 3 units • 2 U Height 6kVA, 3U 10kVA compact design • 0.9 output power factor • DSP Control • Wide Input Tolerance • <7% THDi • 0.98 input Pf • 208 / 220 / 230V Output Selectable • 50/60Hz auto sensing • Cost effective long runtimes

  26. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B8033 10kVA to 40kVA Double Conversion 3/3p IGBT ECO

  27. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B8033 10kVA to 40kVA Double Conversion 3/3p IGBT ECO • 3/3 Phase 10 – 40kVA 3 Years Parts Warranty • High efficiency • Carbon Trust ETL registration September 2011 • True Online Double Conversion Topology DSP • Optional 3 Years peace of mind cover including Batteries and Labour • High Efficiency Online (<95%, 98% SOL MODE) • Input IGBT Rectifier 3% THDi 0.99pf • Modular construction • No DC – DC boost conversion for increased efficiency • Dual Static Switch with full back feed protection • 3/1 Phase 10 – 20kVA

  28. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B8033 10kVA to 40kVA Double Conversion 3/3p IGBT ECO • Rectifier 6 bridge IGBT with DSP • Large input mains variations +10% - 20% • Frequency +/- 5% • 3 %Input THD • Input power factor 0.99 • Integrated adjustable charger • Auto Battery diagnostics • Inverter 6 bridge IGBT with DSP • Vector control real time voltage & current cascade loops • Excellent Output voltage without Derating • High voltage and dynamic response • Static response +/- 1%, Dynamic 100% step load +/- 2% • Output THD 1% controlled via digital recovery loop CBCL • Digital electronic & selectable short circuit protection • Inverter DC controlled via separate loop ASL. IGBT DeSat protection

  29. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B8033 10kVA to 40kVA Double Conversion 3/3p IGBT ECO Smart OnLine (SOL) Mode @ 95-98% efficiency • With Smart OnLine efficiency is considerably increased, allowing high energy saving, depending on the mains and load quality • Additionally to the traditional double conversion on-line (< 95%), and ECO modes (>98%), SOL is an optimised trade-off between the VFI and VFD topology (IEC EN 62040-3) in terms of reliable supply and efficiency

  30. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO

  31. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • The BORRI B9000 and B9600 provides resellers with accessibility to higher end Data Centre and Industrial UPS products without the draw backs of inflated purchase cost, high maintenance cost. • Further the B9000 and B9600 provides unique selling features enabling resellers to compete direct. • Transformer based true Online Double Conversion DSP topology • 3 years parts warranty including batteries • Optional full 3 Years peace of mind cover • Carbon Trust ECA ETL accreditation

  32. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • The B8000, B9000, B9600 range of High Efficiency UPS Systems has Qualified to be officially listed on the Energy Technology List (ETL), as part of the Governments Enhanced Capital • Allowance (ECA) Scheme to reduce power usage, reduce energy costs and reduce carbon emissions. This is a rigorous selection criteria, with only the products that deliver substantial energy savings qualifying. • Open to all businesses that pay UK corporation or income tax, regardless of size, sector or location. • Provides 100% first-year capital allowances on investments in energy-saving equipment against taxable profits of the period of investment. • All the products listed on the ETPL must meet the energy-saving criteria, published in the ETCL • http://www.eca.gov.uk/etl.

  33. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO What differentiates BORRI is that all systems are still ‘Transformer’ based offering the highest levels of isolation, filtering and protection. Listed B9000 60kVA – 300kVA Listed B9600 400kVA – 6.4MVA Example Company made £100,000 taxable profits. Within that tax year £30,000 was spent on B9000 UPS. £30,000 can be deducted of taxable profits. £70,000 taxable. Saving based on 26% corporation tax will be £7,800.00

  34. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • Standard 3 years UPS and Batteries warranty on B9000 and B9600 • Reduces risk of potential 2nd and 3rd year parts costs • Optional maintenance upgrade to include 3 years peace of mind cover • Reduces risk of 2nd and 3rd year maintenance and labour costs • Peace of mind to end user and reseller

  35. Walk-in 5-30s hold-off 1-300s UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • Standard Rectifier Features. • 6 Bridge IGBT Rectifier • 3% THDi, Power factor 0.99 • Fine regulation accepting a wide input voltage range –20% +15% • Adjustable rectifier walk-in time 5-30s (default 10sec) and hold-off time 1-300s (default 1sec)

  36. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • Standard Inverter Transformer. • Reduces the risk of direct feed through of DC to critical load. • Reduces risk of inverter fault by proving protection between inverter switching devices and critical loads. Protects Inverter from loads and parallel UPS inverters • High rejection ration of Spikes, surges • Short Circuit current • Output voltage balance for non-linear or IT loads with a leading power factor up to 0,9. • IGBT optimisation for reduced cost and higher efficiency of low and imbalanced load conditions

  37. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO Smart OnLine Mode (SOL) • The intelligent on-line technology allows to continuously and in real time. • monitoring the mains line, its status and the failure rate over time • monitoring load characteristics, particularly Power Factor (that is current displacement and distortion) • On the basis of this analysis the UPS DSP decides whether to feed the load through the direct line or through the conditioned line, relying on a fast and reliable transfer due to double electronic static switch

  38. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO Smart OnLine (SOL) Mode @ 95-98% efficiency • With Smart OnLine efficiency is considerably increased, allowing high energy saving, depending on the mains and load quality • Additionally to the traditional double conversion on-line (< 95%), and ECO modes (>98%), SOL is an optimised trade-off between the VFI and VFD topology (IEC EN 62040-3) in terms of reliable supply and efficiency

  39. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO Smart parallel up to 8 units In the early days of a redundant parallel UPS system, each UPS can run at very low loads. Generally a result of conservative margins and the customers load not up to full operation. Hence each UPS module is underused and having “excessive” resources. With this over sizing the power conversion efficiency is not optimal. • To prevent an increase on costs of ownership an intelligent “Power Management” is needed • By the Load Based Shutdown (LBS) function UPS modules are shutdown gradually • Increases the load current per UPS, moving the working point to a better efficiency status.

  40. UPS Systems KVA Range 1 2 3 4 5 6 7 8 9 10 20 30 40 60 80 100 200 300 400 500 600 800 B9000 B9600 60kVA to 300kVA Double Conversion 3/3p IGBT ECO 400kVA to 800kVA Double Conversion 3/3p IGBT ECO • New Sync Box for synchronisation of dual UPS parallel systems

  41. Upcoming releases • Primacy Modular UPS 60kVA – 700kVA. due Autumn 2012 • New Rotation model due Autumn 2012 Any Questions?