An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiation modeling for optically thick plasmas Application to plasma diagnostics D. Karabourniotis University of Crete GREECE Plasma Light Model-Inventory workshop, Madeira, April 2005

  2. Outline • General expression of spectral intensity Iλfrom a plasma layer • Εxpressionof Iλwith constant line width • Validity of calculating emissivity by means of a simple empirical radiation model based on the “inhomogeneity parameter” • Numerical validation of a method for determining the “inhomogeneity parameter” from line-reversal • Application to the temperature determination in a Hg-NaI lamp

  3. General expression of side-on intensity The equation of radiation transfer Expression for the side-on intensity Because of the plasma symmetry

  4. Expression of Iλ in terms of emissivity Kλ η=n/g,

  5. Relative distribution functions • For the absorbing atoms: • For the emitting atoms: • For the line profile: • Column density:

  6. Expression of Kλin terms of the optical coordinateY • optical coordinate:

  7. Assumption: • Expression of emissivity Kλ • Condition for reversal at line peak, Ks=K(λο±s) at the line peaks becomes a function of Λ(Y)

  8. A simple empirical plasma model for line self-absorption • Source function: • Alpha: inhomogeneity parameter, with Ks=K(λο±s) becomes a function of alpha, α

  9. Relationship between Ks and α Accuracy of the one-parameter approach for representing Ks better than 3% Karabourniotis, van der Mullen (2004)

  10. s0 Imax Imin (λ- λ0)/δ |s|/δ 0 How the alpha can be determined from line contours? • Contour of a self-reversed line and definitions • δ: half-width of a Lorentzian line profileP(λ)

  11. Construction of a discharge model • Absorbing atoms: • Emitting atoms: • Source function:

  12. τ0 Optical depth at λ0 L(r)U(r) total optical depth at λο along a plasma diameter INPUTS: α(y) τ0(y) τs(y) K0(y) Ks(y) OUTPUTS Numerical experiment Inputs and outputs

  13. Example: Decreasing L(r): a =10, b =20, c = 0.5; Parabolic T(r): T0=6000 K, Tw=1000 K; Eul = 3 eV L Λ U

  14. Input: τ0 =10 at y=0

  15. Experimental data –contour characteristics

  16. alpha Contour characteristics calculated from the one-parameter approach for the source function 1.7 1.6 1.5 Karabourniotis, ICPIG-2005 Inputs: α = 1.62 Ks = 0.520 Results: α = 1.64 Ks = 0.514 alpha 1.7 Dexp 1.6 1.5 log(Imax/Imin)exp

  17. Electron temperature in a 12-atm, 150-W Hg-NaI “standard” lamp

  18. T(5461) T(4047) Telectron Telectron ≡ T(63P2,63P0) Karabourniotis, Drakakis, Skouritakis, ICPIG-2005

  19. Summary • The emissivity at the peak of a self-reversed line is readily obtained if the inhomogeneity parameter (alpha) is known. • The alpha-value can be deduced from the line contours. This was proved through plasma numerical-simulation. • The distribution and the electron temperature were determined in 12-atm Hg-NaI lamp.