1 / 19

EZ-Boom

EZ-Boom. Florent Ciracq Training Specialist EMEA. 26th March 2009. EZ Boom. Automatic Boom Section Control. Automatic Section Control. EZ-Boom 2010 has two main functions: Automated Boom Section control User definable from 1 to 10 sections

aleron
Télécharger la présentation

EZ-Boom

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EZ-Boom Florent Ciracq Training Specialist EMEA 26th March 2009

  2. EZ Boom

  3. Automatic Boom Section Control

  4. Automatic Section Control • EZ-Boom 2010 has two main functions: • Automated Boom Section control • User definable from 1 to 10 sections • Detects already sprayed areas and turns off boom sections accordingly • Sections can vary in width independently • Rate Control • Adjusts the flow control valve to achieve Target Rate using: • User defined Target Rate - can be a prescription when used with the FieldManager Display • Vehicle speed (GPS) • Boom width (which varies as the sections get turned off/on)

  5. EZ Boom (Designed in EU) • Automatic Section Control Only • Sprayers • Pull Type • Self Propelled

  6. Hardware Option

  7. Display Options • EZ-Guide Plus • EZ-Guide 500 • Field Manager Display • FM-1000

  8. EZ-Guide 500 interface

  9. EZ-Guide 500 interface

  10. Field Manager Display interface

  11. Controls

  12. Connecting to the implement The connectivity options are • Spa Coupe

  13. Demonstration installation

  14. EZ-Guide 500 Interface • Run –Time Screen

  15. 500 Interface

  16. 500 Interface • RTF Reports • Applied Rate • GPS Quality • Height • Overlap • Similar to FMD, FM-1000

  17. EZ-Guide 500 Interface • Configuration • Boom Set-Up

  18. EZ-Guide 500 Interface Valve on latency – The time is takes to the system to start spraying once it switched on. Valve latency off – The time it takes for the system to stop spraying once it is turned off. Intension overlap – Metres or inches of overlap

  19. Questions

More Related