1 / 16

Progress Report

Application of Electrical Impedance Tomography for Imaging in Bio-Medical and Materials Technology. Progress Report. I. DETAILS OF PROJECT. Project Number :01-02-03-SF0024

amora
Télécharger la présentation

Progress Report

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Application of Electrical Impedance Tomography for Imaging in Bio-Medical and Materials Technology Progress Report

  2. I. DETAILS OF PROJECT • Project Number :01-02-03-SF0024 • B) Project Title :Application of Electrical Impedance Tomography for imaging in bio- medical and materials technology • C) Project Leader :Farrukh Nagi • D) Period of Performance :18 months • E) Date of Commencement :December 2006 • F) Date of Completion :May 2008

  3. II. Description Electrical Impedance Tomography (EIT) is a non-invasive imaging technique that has applications in the crack detection , medical field [1] and industrial processes. For instance,EIT has been used to image lung functions. Additionally, EIT has been used to determine pulp consistency, which can be integrated into a process control loop in the paper manufacturing process. EIT is based on the principal that different materials have different electrical properties. EIT imaging exploits these properties (i.e. impedance) to produce a cross sectional image in a non-invasive manner.

  4. III. Gantt Chart

  5. Contd ……Gantt Chart

  6. IV. Project activities From Date To Date • Purchasing Activity 01/12/2006 01/09/2007 • Electrical Impedance Tomography - updates 01/01/2007 01/05/2008 • Design Criteria and equipment selection 01/01/2007 01/06/2007 • Computer modeling and development of Inverse • Boundary value problem01/04/2007 01/12/20 • Development of Target equipment 01/06/2007 01/05/2008 • Application program interface 01/06/2007 01/05/2008 • Testing, experimentation, performance measure 01/07/2007 01/05/2008 • Integration of Hardware 01/08/2007 01/11/2007 • Computer interfacing 01/09/2007 01/12/2007

  7. V. Key Milestones • Milestones Date • Mathematical implementation of inverse boundary • value problem 01/01/2008 • Hardware and software interface 01/06/2007 • Interface with Target 01/12/2007 • Image re-construction 01/04/2008 • Project Completion 01/05/2008

  8. VI. Expenditures • Total amount approved: RM 139,000 • Total amount spent: RM 53, 800 • Balance RM 85,200 • Development of electrode tank + accessories and Purchase order approved for DAQ • Purchase orders photo copies are available

  9. VII. Work Completed • Inverse boundary value problem -computer program • Computer simulation and verification of the software • Electrode tank is manufactured

  10. Inverse Algorithm Problem Solving with FEM

  11. EIT -Simulation in Matlab

  12. EIT -Electrode Tank for Experiment Electrodes for connection with Hardware

  13. Multi-Channel Matrix Data Acquisition System Awaited....

  14. VIII. Problem Faced in Procurement of Data Acquisition Equipment : ~RM 44, 000 • Funds were not sufficient to make the purchase in May 2007 • Written letter to MOSTI, June 2007, for early release of funds for the purchase • Dec. 2007, No reply............ • Funds were made available by RMC-UNITEN from other resources • Jan 2008, restart the purchasing activity as the quotation expired and re-process the procurement formalities. • April 2008 – Agent of the Equipment ‘National Instrument’ is in receipt of supplying the equipment now

  15. IX. Request for Extension In Project Duration • Request for one year extension • Sufficient budget • Extension is requested to complete the Imaging • process from the purposely build electrode tank

  16. THANK YOU