1 / 60

REPLACING MERCURY CONTAINING PRODUCTS AND MERCURY THERMOMETERS IN ASTM STANDARDS Technical and Legal Issues

REPLACING MERCURY CONTAINING PRODUCTS AND MERCURY THERMOMETERS IN ASTM STANDARDS Technical and Legal Issues. Presented by Jim & Deanne Emory Miller & Weber, Inc. Ridgewood, NY June 26, 2007. Deanne Miller Emory President & Owner of Miller & Weber, Inc. Precision Glass Instruments

anakin
Télécharger la présentation

REPLACING MERCURY CONTAINING PRODUCTS AND MERCURY THERMOMETERS IN ASTM STANDARDS Technical and Legal Issues

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. REPLACING MERCURY CONTAINING PRODUCTS AND MERCURY THERMOMETERS IN ASTM STANDARDSTechnical and Legal Issues Presented by Jim & Deanne Emory Miller & Weber, Inc. Ridgewood, NY June 26, 2007

  2. Deanne Miller Emory President & Owner of Miller & Weber, Inc. Precision Glass Instruments Ridgewood, NY Chairman, E20.05 Liquid-in-Glass Thermometers & Hydrometers Chairman, ASTM E20 Mercury Project Task Group Secretary, E20.04 on Thermocouples Member-at Large, D02 Committee on Petroleum James E. Emory, Jr. Judicial Referee and Senior Court Attorney New York State Office of Court Administration Member, E20 Committee on Temperature Measurement CONTACT US: DeanneMEmory@aol.com (718) 821-7110

  3. Abstract At the request of several States, ASTM International has issued a directive to all technical committees to review their standards that reference mercury containing instruments or mercury methods and determine the technical and economic feasibility of replacing them or substituting with non-mercury instruments or methods. A number of States have banned the sale of mercury containing instruments, including ASTM mercury thermometers, making it difficult for users in those States to comply with ASTM standards. In most cases, the instruments in question are the mercury-in-glass thermometers specified in ASTM E1. These thermometers have long been the gold standard temperature measurement devices in many ASTM standards. In this presentation we will review the ASTM directive, including how to communicate the technical committees’ resolutions to ASTM; technical issues in replacing mercury containing devices with other devices, especially the thermometers found in ASTM E1; legal issues involved with this project, including which States have bans and how the bans differ from State to State. We will leave discussion time at the end of the presentation.

  4. How did this start?

  5. NEWMOA The Northeast Waste Management Officials’ Association based in Boston, Massachusetts found at www.newmoa.org

  6. Connecticut Maine Massachusetts New Hampshire New Jersey New York Rhode Island Vermont NEWMOA was established by the Governors of the New England states as an official regional organization to coordinate interstate hazardous and solid waste, and pollution prevention activities and support state waste programs, and was formally recognized by the U.S EPA in 1986. Member States

  7. IMERC • In 2001, NEWMOA established IMERC--- the Interstate Mercury Education & Reduction Clearinghouse. • The State- Laws we will discuss first came out of this Clearinghouse. • IMERC States include all of the NEWMOA states and California, Illinois, Minnesota, North Carolina and Washington.

  8. ASTM INITIATIVE

  9. ASTM Involvement • In January 2006, state environmental agencies became aware of Federal and State rules and regulations that require the use of ASTM standards. Many of these standards require the use of mercury in glass (ASTM E1) thermometers. • States began to lobby ASTM to remove requirement of mercury in their standards.

  10. ASTM Search • In response to the requests, ASTM searched through their standards for references to ASTM E1, mercury, mercury-in-glass thermometers and liquid-in-glass thermometers. • ASTM E1 is the most referenced standard within ASTM- it is referenced in over 900 standards.

  11. ASTM Response • ASTM Headquarters has requested each technical committee to review standards and determine whether the use of “mercury” or “mercury products” is appropriate; if it can be replaced or supplemented with non-mercury methods or products; if the reference should be removed without replacement of method or product.

  12. ASTM E20 Mercury Project Task Group • Consists of seven members of ASTM Committee E20 to help provide technical guidance to the committees affect by this review. • We have technical experts in liquid-in-glass thermometry, resistance thermometry, themocouples, radiation thermometry, thermistors and in calibration and construction. • Guidance document developed for distribution to Subcommittee Chairmen and is available today.

  13. ASTM Committee E20 on Temperature Measurement Overview of Committee and Committee Standards

  14. Technical Subcommittees • E20.02 Radiation Thermometry • E20.03 Resistance Thermometry • E20.04 Thermocouples • E20.05 Liquid-in-Glass Thermometers and Hydrometers • E20.06 New Thermometers & Techniques • E20.07 Fundamentals • E20.08 Medical Thermometry

  15. Liquid-in-Glass Thermometers ASTM E1 “Standard Specification for ASTM Liquid-in-Glass Thermometers” ASTM E77 “Standard Test Method for Inspection and Verification of Thermometers” ASTM E2251 “Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids” Hydrometers & Thermohydrometers ASTM E100 “Standard Specification for ASTM Hydrometers ASTM E126 “Standard Test Method for Inspection, Calibration and Verification of Hydrometers NEW “Standard Specification for ASTM Thermohydrometers using Non-Mercury Liquids” NEW “Standard Specification for Electronic Thermohydrometers (densitometers) using the Digital Buoyancy Method” NEW “Standard Test Method for Calibration and Verification of Electronic Thermohydrometers (Densitometers)” ASTM Committee E20 Temperature MeasurementASTM Subcommittee E20.05 Liquid-in-Glass Thermometers and Hydrometers

  16. ASTM Committee E20 Temperature MeasurementOther Standards of Interest • Resistance Thermometry E644- Standard Test Methods for Testing Industrial Resistance Thermometers. E1137- Standard Specification for Industrial Platinum Resistance Thermometers • Thermocouples E220- Standard Test Method for Calibration of Thermocouples by Comparison Techniques E230- Specification for Temperature- Electromotive Force (EMF) Tables for Standardized Thermocouples • Fundamentals E563- Standard Practice for Preparation and Use of an Ice-Point Bath as a Reference Temperature

  17. SUMMARY STATE BANS ON MERCURY-IN-GLASS THERMOMETERS as of June 15, 2007

  18. CALIFORNIAEffective July 1, 2006 A person shall not sell, offer to sell, or distribute for promotional purposes, any of the following new or re-furbished mercury-added products…. Barometer… flow meter… hydrometer… hygrometer… psychrometer… manometer… pyrometer… thermometer. This does not apply to the sale of a mercury-added product if the use of the product is required under federal law or federal contract specification or if the only mercury-added component in the product is a button cell battery. California Codes Health and Safety Code 25214.8.3.

  19. CONNECTICUTEffective July 1, 2004 (add’l req. July 1, 2006) … no person shall offer for sale or distribute for promotional purposes any mercury-added product if the mercury content of the product exceeds 100 mg in the case of fabricated mercury-added products or 50 ppm in the case of formulated mercury added products Manufacturer may apply for an exemption. Connecticut Chapter 446m Mercury Reduction and Education Sec 221-617.

  20. INDIANAEffective July 1, 2003 A person may sell or provide a mercury commodity to another person in this state (other than for collecting for recycling) only if: (1) the person selling or providing the mercury commodity provides an MSDS… (2) person selling or providing the mercury commodity requires that the purchaser or recipient will (a) use the mercury only for medical purposes, in dental amalgam, dispose-caps, for training, for research or for manufacturing purposes (b) understands that mercury is toxic, (c) will store and use properly.. (d) will not intentionally place… in solid waste for disposal or in a wastewater disposal system. Indiana IC 13-20-17.5-5

  21. MAINEEffective July 1, 2006 A person shall not sell or offer to sell or distribute the following mercury-added products: Barometer… flow meter… hydrometer… hygrometer or psychrometer… manometer… pyrometer… thermometer… This section does not apply to the sale of the above products if the use of the product is a federal requirement or if the only mercury-added component in the product is a button cell battery. Manufacturer may apply for an exemption. Maine Title 38, Chapter 16-B, Section 1661-C-6

  22. MASSACHUSETTSEffective May 1, 2007 Manufacturers of products to which mercury has been intentionally added and that are sold in the state must establish a system of collecting them at the end of their useful lives, and for recycling their mercury contents. The plan must be approved and certified by the department. Unless the mercury-added product is required under federal law. Massachusetts Chapter 190 of the Acts of 2006, Section 6J

  23. MICHIGANEffective January 1, 2003 (Ban includes) all mercury thermometers sold or offered for promotion… …except those (1) required by state or federal statute, regulation, or administrative rule, (2) used for pharmaceutical research purposes. Enforcement shall be done by dept of environmental quality. A person who violates this part is guilty of a misdemeanor punishable by imprisonment of not more than 60 days or a fine of not more than $1,000.00, or both, plus the costs of prosecution. Michigan Act 451 of 1994, Sections 324.17201 & 324.17202

  24. MINNESOTAEffective January 1, 2002 Includes all mercury thermometers manufactured after June 1, 2002, Except those (1) used for food research and development or processing, (2) are a component of an animal agriculture climate control system or industrial measurement system, until a system is replaced or a non-mercury component is available, (3) used for calibration of other thermometers, apparatus or equipment unless a nonmercury calibration standard is approved by NIST and (4) electronic thermometers with button cell batteries. Minnesota Chapter 47- H.F. No 274

  25. NEBRASKAEffective May 20, 2003 No liquid mercury thermometer containing elemental mercury shall be sold, given away, or otherwise distributed in this state. No exceptions in statute. Nebraska Chapter 28, Section 28-1349 & 28-1350 (Laws of 2003, LB 17 Section 3 & 4)

  26. NEW YORKEffective January 1, 2007 (Bans) all mercury-added manometers and hydrometers, except those used to replace a product that is a component in a larger product in use prior to January 1, 2007, or the resale of a manometer or hydrometer manufactured before December 31, 2006. New York Title 21, Section 27-2107,6

  27. NEW YORKEffective January 1, 2008 Cannot sell, offer for sale, or distribute mercury-added thermometers if a non-mercury alternative is available. Commission will review this by February 2008 and rule if non-mercury alternatives are available. Excludes mercury-added thermometers that are a component of a larger product in use prior to January 1, 2008 or resale manufactured before January 1, 2008; excludes if the use is a federal requirement. New York Title 21, Section 27-2107,8

  28. RHODE ISLANDEffective January 1, 2006- revise 1/1/07 & 1/1/08 No mercury added product shall be offered for final sale or use or distributed for promotional purposes in the state if the mercury content of product exceeds 1 gram for fabricated products and 250 ppm for formulated products. Excludes are lighting for entertainment industry and fluorescent lamps and HID lamps. Manufacturers may apply for exemption. Rhode Island Title 23, Health & Safety, Mercury Reduction & Eductation Act. Chapter 23-24.9-7

  29. VERMONTEffective January 1, 2007 Restricts the sale of thermometers that contain elemental mercury Excludes if it is for a Federal requirement. Also … barometers… flow meters… hygrometers & psychrometers… manometers… hydrometers. Excludes Hygrometers, psychrometers & manometers if replacing into larger device in place before 1/1/07. Exemptions may be granted. Vermont Chapter 164, Section 7105

  30. WASHINGTONEffective January 1, 2006 (Ban) includes all mercury thermometers… except those (1)electronic thermometers with a button cell battery containing mercury (2) used for food research and development or processing including meat, dairy products, and pet food processing, (3) are a component of an animal agriculture climate control system or industrial measurement system, until a system is replaced or a non-mercury component is available, (3) used for calibration of other thermometers, apparatus or equipment unless a nonmercury calibration standard is approved by NIST and (4) electronic thermometers with button cell batteries. Washington Chapter 70.95M.050

  31. So, how do we substitute for this?

  32. Automated Viscometer Automated Cloud & Pour

  33. What about our manual methods?

  34. Thermometer Types • Standard Platinum Resistance Thermometers (SPRTs) (very accurate, but susceptible to shock) 13.8 K to 962 °C (Calibration uncertainty less than 0.001 °C *) • Industrial Platinum Resistance Thermometers (IPRTs) –196 °C to 850 °C (Calibration uncertainty less than 0.01 °C *) • Thermistors –10 °C to 100 °C (Calibration uncertainty less than 0.005 °C *) • Liquid-in-Glass Thermometers –150 °C to 400 °C (Calibration uncertainty between 0.02 and 0.5 °C *) • Thermocouples –196 ° C to 2100 °C (Calibration uncertainty between 0.3 and 1 °C *) * U (k=2) Information courtesy of NIST

  35. Digital Thermometers • A digital thermometer is an electronic “box” that converts either resistance or emf of a thermometer to temperature. • Platinum Resistance Thermometers, thermistors and thermocouples in disguise. Pictures courtesy of Fluke/Hart Scientific, ASL and WL Walker Co.

  36. Thermometer Types:Calibration Ranges and Uncertainties Chart used with permission of NIST Thermometry Group

  37. Determine Differences in Scale Error and UncertaintiesPRT’s and Thermistors Used with permission of the NIST Thermometry Group

  38. Determine Differences in Scale Error and UncertaintiesThermocouple Sensors Used with permission of the NIST Thermometry Group

  39. Additional Constraints • Sensor should be hermetically sealed in stainless steel sheath of outer diameter no larger than the bulb diameter of the E1 thermometer. • When substituting for a partial immersion thermometer, immerse at least as deep as you would the glass thermometer. A bias may be introduced due to temperature gradients in the ASTM apparatus if the immersion is very different from the glass thermometer. • When substituting for a total immersion thermometer, the center of the alternative sensor should be placed at a depth equal to the center of the liquid-in-glass thermometer. Again, bias may be introduced since PRT can be fixed in place and there may be temperature gradients. • PRTs should be fabricated to ASTM E1137. • Thermistors should be fabricated to ASTM E879. • Thermocouples should be fabricated either of soft-insulated wire mounted in stainless-steel sheaths similar to the mountings described in E879 or E1137, or of mineral insulated construction in conformance with E608.

  40. General Issues with Replacing Mercury-in-Glass Thermometers in ASTM Standards

  41. ASTM Total ImmersionLiquid-in-Glass Thermometers • Total immersion thermometers, when properly used have immersion depths that vary with temperature. • Some ASTM total immersion thermometers (such as ASTM Calorimetry thermometers) are not manufactured to measure absolute temperature. • ASTM Kinematic Viscosity thermometers have ice points that do not read absolute temperature. • Many ASTM total immersion thermometers (such as distillation and saybolt viscosity thermometers) are used as partial immersion thermometers.

  42. ASTM Distillation Manual MethodsASTM 8C vs Electronic Thermometer

  43. ASTM Partial ImmersionMercury-in-Glass Thermometers • Many ASTM partial immersion mercury-in-glass thermometers have “artificially” high or low emergent stem temperatures. • Study of differences in readings of mercury-in-glass thermometer and substitute thermometer (whether liquid-in-glass or electronic must be made before relying on the substitute thermometer. • Special care must be taken when substituting in timed tests (ie flashpoint). Rate of rise and lag time must be accounted for.

  44. Typical Alternative Liquidstypically available in thermometers • Toluene (ASTM 6C & ASTM 114C) • Kerosene • Mineral Spirits • Silicones • Citrus Oils • IsoAmyl Benzoate Properties of Typical Alternative Liquids as Compared to Mercury Less hazardous than mercury Reaction time descending up to fifteen minutes. Repeatability less precise than mercury

  45. Typical non-mercury thermometers do not have tolerance, repeatability or response time adequate for use in ASTM standards. WHY?

  46. Behaviors of Traditional Liquids in Glass Capillaries

  47. Desirable Behaviors of Mercuryas a Thermometric Liquid • Expands Uniformly • Wide useable range (-39 to 500 °C) • Reaction time three minutes • Repeatable measurement capability

  48. ASTM E2251 “Standard Specification for Liquid-in-Glass ASTM Thermometers with Low-Hazard Precision Liquids” • Written by the NIST Thermometry group and members of ASTM E20.05 based on the research presented at the 8th International Temperature Symposium in October 2002. • Accepted by ASTM Committee E20 in November 2002. • Published by ASTM in February 2003.

  49. “Preliminary Results of a New Type of Non-Hazardous Liquid-Filled Precision Glass Thermometer” • Research presented at the 8th International Temperature Symposium in Chicago, Illinois October 2002. • Research published by the AIP in the Conference Proceedings. CP684, Temperature: Its Measurement and Control in Science and Industry, Volume 7. Edited by Dean C. Ripple.

  50. PROPERTIES REQUIRED OF ASTM E2251 THERMOMETERS • Liquid column will ascend or descend with change of temperature so that top of liquid column reaches final position within 3 minutes of attaining temperature to be measured. • Liquid column will descend through a contraction chamber or ice point chamber and will reach final position within 3 minutes of attaining temperature to be measured. • Liquid is biodegradable • Liquid is non-toxic in thermometer quantities (per 49 CFR 1910.1200) • Liquid is non-hazardous (per EPA Regulations) • Thermometer will give repeatable results similar to those expected of a mercury thermometer • Thermometer will give reproducible results similar to those expected of a mercury thermometer

More Related