An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. THE MODELING OF THE LIMIT STATE OF DUCTILE THICK-WALLED PIPES WITH AXIAL SURFACE DEFECTS Orynyak I.V., Ageyev S.M. G.S. Pisarenko Institute for Problems ofStrength, Kiev, Ukraine

  2. Plan • Existing models for pipes with defects. • The problems of modeling of the thick-walled pipes. • The proposed analytical model for thick-walled pipes. • The theoretical analysis of the results. • The comparison with experimental data. • Discussion. • Application to a repair technology.

  3. Existing models for pipes with defects C – crack half-length ℓ – crack half-width a – crack depth - dimensionless ligament thickness - dimensionless crack length • dimensionless limit pressure or • strength reduction coefficient - «local» formula of the Battelle Memorial Institute - «global» formula of the Battelle Memorial Institute - «global» formula Staat - «local» formula Staat - formula DNV

  4. The problems of modeling of the thick-walled pipes 1. The choice of limit characteristic.2. The choice of criterion of ductile failure. 3. The irregularity of defect’s form. 4. Interaction of closely situated defects. 5. The taking into account the wall thickness. 6. External/internal defects.

  5. The choice of limit characteristic

  6. The choice of criterion of ductile failure (for unflawed thick-walled pipes).

  7. The proposed analytical model for thick-walled pipes.Analytical model of the Institute for problems of strength (for thin-walled pipes) • the equation of forces equilibrium • in the radial direction - the circumferential force; х– axial coordinate; - transverse force - limit condition - external - internal dimensionless limit pressure for the thin-walled pipe with axial surface defect

  8. External/internal defects the limit bending moment

  9. The taking into account the wall thickness • local equation of equilibrium • for thin-walled pipe • the solution of differential equation The pipe with external defect The pipe with internal defect

  10. The theoretical analyze of the results The dimensionless limit pressure versus dimensionless crack length for the model of thick-walled pipes with external/internal defects. The comparison of analytical models for thin-walled pipe: and for the thick-walled pipe:

  11. The comparison with experimental data(Staat’s data) internal external

  12. - “external” formula 1. The comparison our models with experimental data for the pipe with internal defect. - “internal” formula 2. The comparison our models with Staat’s “local” formula. internal external 3. The comparison our models with Staat’s “global” formula. internal external

  13. Discussion Influence of the form of the defects external (Staat)

  14. Application the pipe with sleeve the pipe with defect - pipe’s geometry - defect’s geometry - the pipe without defect 1. 2. - the pipe with defect 3. Numerical analyze and simplify analytical model - the added thick pipe’s wall as a result of used sleeve (equal 8 MPa) - the pipe with sleeve 4. 5. - experiment