1 / 24

NYSDEC Stormwater Permits TMDL Conditions and Retrofit Options

NYSDEC Stormwater Permits TMDL Conditions and Retrofit Options. Shohreh Karimipour, P.E. MS4 Permit & TMDL. Designation of additional MS4s in TMDL watersheds 2003 - Extend past areas to boundaries of New York City drinking water watershed East of Hudson 2003 - Extend Eastward in Long Island

armand
Télécharger la présentation

NYSDEC Stormwater Permits TMDL Conditions and Retrofit Options

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NYSDEC Stormwater Permits TMDL Conditions and Retrofit Options Shohreh Karimipour, P.E.

  2. MS4 Permit & TMDL • Designation of additional MS4s in TMDL watersheds • 2003 - Extend past areas to boundaries of New York City drinking water watershed East of Hudson • 2003 - Extend Eastward in Long Island • 2008 - Peconic Estuary TMDL designates Eastern Long Island

  3. NYC EOH Watershed Improvement Strategy Local Requirement for E&SC - 5,000 ft2 to 1 acre (12/31/2009) Local SWPPP Review Against Enhanced P Removal (9/30/2008) Map entire storm sewer system over 5 years Retrofit plan and schedule 3/9/2009 (alone), 12/31/2009 (RSE) Septic Inspections, Maintenance, and Rehabilitation/3 Yr. Targeted Education and Outreach Specific System Maintenance Requirements Specific Turf Management Requirements Leaf and Yard Waste Control Requirements

  4. Loading Assessments • By 1/8/2013 model relative changes in load to impaired waters (no TMDL) with non-negligible changes to land areas or practices • By 1/8/2013 model to assess progress in reducing the pollutant of concern to meet TMDL • Modeling alternatives in responsiveness summary (Appendix D)

  5. Enhanced Phosphorus Removal Sizing Criteria

  6. Retrofits • Retrofits are modifications or additions to existing infrastructure to reduce pollutant loadings. Examples (pp72 and 73): • Better Site Design Approaches • Storm Sewer Rehabilitation • Stabilizing Dirt Roads • Conversion of Dirt Parking to Pervious Pavement • Conversion of Dry Ponds to Detention Ponds or Wetlands • Converting Abandoned Buildings to Open Space or SMP • Control of Downstream Erosion Effects • Direct Control Erosion Effects (Plunge Pool, Velocity Dissipaters) • Upgrade of Existing Conveyance to Provide Quality and Quantity Control • Reforestation

  7. Retrofit Permit Requirementsin April, 08 MS4 Permit • Identify sites with problems • Choose projects based on: • Pollutant reduction potential • Use of proven technologies • Economic feasibility • Procedures for design, permits, funding, O&M • Approvable plans, schedules and funding sources

  8. Retrofit Permit RequirementIn April, 08 MS4 Permit • East of Hudson MS4s acting alone submit approvable plan and schedule by March 9, 2009 • East of Hudson MS4s in RSE submit by December 31, 2009 • Onondaga, Greenwood Lake, Oyster Bay, Peconic MS4s submit by March 9, 2011

  9. DEC Retrofit/Modeling Paper • Basis for Retrofit Section of TMDL Implementation • Short term expectations: simpler retrofits- e.g. ditches to dry swales, erosion repairs and disconnecting rooftops ~ 0.3 - 0.5 lb/acre/yr • Long term expectations: more sophisticated retrofits - more sophisticated targeting - considering cost effectiveness • Load reductions for retrofits can be assigned using WTM or Win-SLAMM

  10. Other Key Points • Older TMDLs do not distinguish MS4 loads from non-point source • MS4 load reduction would be achieved with Retrofits and non-structural BMPs • Retrofits may include Redevelopment or routine system upgrades • Guidance: Urban Stormwater Retrofit Practices Manual • Desktop Assessment & Retrofit Reconnaissance Investigation

  11. East of Hudson TMDL Implementation Plan Concepts • Establish sustainable annual mass reductions and maximum 15 year schedule • Apportion reductions by MS4 – for Phosphorus, base apportions on high intensity development • Allow for bubble or individual load reductions • Reductions credited based on modeling projects • Re-evaluate every five years ( use monitoring data/modeling)

  12. Greenwood Lake Watershed Improvement Strategy Local SWPPP Review Using Enhanced P Removal by 9/30/2008 Watershed Based Retrofit plan and schedule 3/9/2011 Septic Inspections, Maintenance, and Rehabilitation/3 Yr Targeted Education and Outreach

  13. Onondaga Lake Watershed Improvement Strategy Local SWPPP Review Using Enhanced P Removal by 9/30/2008 Watershed Based Retrofit plan and schedule 3/9/2011 Targeted Education and Outreach

  14. Oyster Bay and Peconic Watershed Improvement Strategy (Pathogens) Watershed Based Retrofit plan and schedule by 3/9/2011 Septic Inspections, Maintenance, and Rehabilitation/ 3 Yr Targeted Education and Outreach Pet Waste Control Goose Population Management

  15. Peconic Watershed Improvement Strategy (Nitrogen) Watershed Based Retrofit plan and schedule by 3/9/2011 Septic Inspections, Maintenance, and Rehabilitation/3 yr. Targeted Education and Outreach Specific Turf Management Requirements

  16. Other TMDL Implementation Plans • EPA required TMDL Plans • Follow similar process for other watersheds • Potential change of criteria at end point • Mostly phosphorus limited watersheds • Albany area, Monroe Co., down state • Implementation plan would provide direction for what would be approvable

  17. Questions

More Related