Electrical Architecture and Interfaces

Electrical Architecture and Interfaces. Pierre PRAT Progress Meeting @APC the 12.10.2012 Michel DUPIEUX. Grounding. Grounding Design is now stable after Johan Panh’s Remarks. Grounding principles. In order to avoid ground loops: Use of galvanically isolated DC/DC converters

arva
Télécharger la présentation

Electrical Architecture and Interfaces

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electrical Architecture and Interfaces Pierre PRATProgress Meeting @APC the 12.10.2012 Michel DUPIEUX

  2. Grounding • Grounding Design is now stable after JohanPanh’s Remarks

  3. Grounding principles • In order to avoid ground loops: • Use of galvanically isolated DC/DC converters • Primary grounds (28V Battery) shall be connected on Mechanical ground of PWP • Secondary grounds of DC/DC converters shall be connected on a single point on Mechanical ground of sub-equipments (DP, PDM) • Mechanical grounds connected together • Differential links (LVDS) between HK, CCB and PDM_Board, HVPS-1

  4. Harness shielding • According to the recommendations of Johan Panh: • Primary power supplies : twisted pairs, not shielded • Secondary power supplies : • LVPS-PDM <==> PDM_Board : twisted pairs, shielded, with shielding connected to mechanical ground (360°) on each sides (HF immunity) • HVPS-1 <==> HVPS-2 : twisted pairs, shielded, with shielding connected to mechanical ground on HVPS-1 side and open on load (BF immunity) • LVPS-HK, LVPS1-DP, LVPS2-DP <==> HK, CCB, CLKB, GPSR, CPU, DST: twisted pairs, not shielded (TBC: internal connection of DP) • Differential digital links: twisted pairs, shielded, with the shielding connected to mechanical ground (360°) on each side

  5. HVPS-1 - HVPS-2 - HK - PDM-Board Interface Synoptic : 1st flight version 28V (S) BAT_RET (P) 1 GND_28V (S) 3.3V (S) 28V_BAT (P) 2 GND_3.3V (S) D-Sub 9 F D-Sub 9M D-SUB 25 F D-SUB 25 M 6 C-W 3 C-W 6 x 14 HV lines 3 ON/OFF 3 0-2.44V 3 STATUS 4 SWITCHCOMMANDS 3 x 14 HV lines HVPS-2 HVPS-1 CS_DAC CS_DAC MOSI 6 SCK 3 MOSI 0-2.44V 6 DAC 3 DAC CS_OUT SCK CS_IO 9 6 bidirectional signals ON/OFF I/O expanders MOSI MISO 9 6 status signals D-Sub 9M SCK STATUS D-Sub 9 F Interrupt 4 SWITCHCOMMANDS MOSI MISO SCK Interrupt 2 2 2 2 2 2 2 2 2 2 2 differential transmitters GND_M 4 differential receivers 4 differential receivers GND_M BATTERY 24 wires D-Sub 15 F 6 Differential signals (LVDS) ( x2 = 18 wires)between HK and HVPS-1 D-Sub 15 M 4 Differential signals (LVDS) ( x2 = 8 wires)between PDM_Board and HVPS-1 Micro-D 9 M D-Sub 15 M D-Sub 15 F Micro-D 9 F GND_M HK PDM_Board 4 differential transmitters HVPS-1 would have DC/DC converters to isolate the powers 4 differential transmitters 2 differential receivers

  6. HVPS • Architecture and I/F are now stable: • 2 HVPS boxes in PDM box: • HVPS-1: • 2 CV DC/DC (28V & 3.3V) for ground isolation • SPI I/F with HK, • LVDS I/F with PDM-Board (switch pulses), • 3 DACs (HV tuning), • 3 Cockcroft-Walton Converters. • HVPS-2: • 6 DACs (HV tuning), • 6 Cockcroft-Walton Converters.

  7. Subd25 or 37? Subd25 or µSubd9? HK • Electrical Interfaces are clearlydefined (connectors, pinout Ok)

  8. DP Block Diagram

  9. DP connectors ? • Pinout and connectorsneed to bechecked and update verysoon

  10. PDM Power connections PDM BOARD Connector PDM_EC_ASIC 3.3Va_EC (S) EC-ASIC TES 1-0511V GND_3.3Va_EC (S) 3.3Vd_EC (S) LVPS-PDM Connector PDM-LVPS GND_3.3Vd_EC (S) 5V_EC (S) 1.5V_EC (S) GND_5V_EC (S) GND_1.5V_EC (S) Regulator EC_ASIC 1 GND_M GND_1.5V_EC should be linked to the gnd of the FPGA 5V_PDMB (S) FPGA 1V GND_5V_PDMB (S) 1.8V FPGA ground should be linked to the GND_M 1.5V 3.3V GND_M • Pinout and connectorsbetweenPDM_Board and EC_Asic are checked

  11. Interfaces with: • CCB µSubd51 • HVPS µSubd9 • HK µSubd9? Subd25 on HK? • POWER Subd9 120 pins PDM ASIC A ASIC B ASIC C ASIC D ASIC E ASIC F A B C D E F 68 pins 68 pins 68 pins 68 pins 68 pins 68 pins Fixation screw EC_HV Kaptoncable MAPMT

  12. PWP PWP-outside 9 pins Sub-D connector PWP2-Outside Power 22W??Which dimensions PWP1-Inside Power 250 W ?? All connectors on a single side To IR-CAM To LVPS-DP1 LVPS-DP2 LVPS-PDM LVPS-HK HVPS1 Plus twoadditional PWP-Inside

  13. PWP Componant Battery Cells,Connectors and Cables • Cells • Connectors • Cables • Option I: In case of 90W powerconsumptionitwillbenecessary 20 cells of Saft G62/1.2 • Option II: In case of 250W powerconsumptionitwillbenecessary 50 Cells of Saft G62/1.2 The Connectors we are going to use are 9 pins D-Sub connectors for all interfaces and subsystems. The Cables we are going to use are THERMAX MIL-DTL-22759/91,92 for all interfaces and subsystems.

  14. PWP Power Budget ?? • 250W • 90W Total Power Budget: 74W+20% of Security Margin = 90W Total: 111.2W+20% of security Margin = 133.4W Additional Heaters and backup = 70W (150+60)+20% of security Margin = 243.6W Thisversionshouldbediscussed • Whichcongiuration for Baseline? • Which power for Pack2 for IR Camera?

  15. Femealeconnector? Short circuit risk? PWP • Femealeconnector on power side • PinOut of External Power • Common Ground or GroundSwitching ? • Pinout Compatibility withLVPSsand HVPS1 ? • IR Camera the samewaywithseparateBattery? • WhoProvidesMaterial and cables?

  16. SIREN HK 232/422 DP • Electrical Interfaces are clearlydefined (connectors, pinout Ok)

  17. Cables • Whoprovidecablesbetween: • HK and SIREN ? • HK and DP ? • PDM and DP ? • DP and SIREN ? • PWP_1 and LVPS (4)? • PWP_1 and HVPS_1? • LVPS_PDM and PDM? • HK et HVPS_1? • PDM_and HVPS_1? • CCB and PDM_board? • HK et PDM Board? • IR Camera ?

  18. ToDo • Which Power budget PWP_1 ? • Clarify Power Pack interfaces. • Whoprovides Batteries (PowerPack 1 and Power Pack 2 ? • Clarifyinternal and external interfaces for DP (update Synoptic). • Definecables, providers ? • Use in generalFemealeconnector on Fixed on boxes exept for power side to avoid short circuit risk!!! • Documentation