Vittorio Marinozzi 10/28/2013

MQXF state of work and analysis of HQ experimental current decays with the QLASA model used for MQXF . Vittorio Marinozzi 10/28/2013. 1.1 MQXF state of work. Current decay with dumping resistance are faster than expected, because of high dI / dt effects

asasia
Télécharger la présentation

Vittorio Marinozzi 10/28/2013

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MQXF state of work and analysis of HQ experimental current decays with the QLASA model used for MQXF Vittorio Marinozzi 10/28/2013

  2. 1.1 MQXF state of work Current decay with dumping resistance are faster than expected, because of high dI/dt effects Considering residual bronze in cables causes a drop of ~30 K in the hot spot temperature estimation

  3. 1.2 dI/dt effects • 13 kA @ 1.9 K (0.7 of SSL) • 60 mΩdumping resistance • No PH • Dynamic effects confirmed with the cored cable, too. With 60 mΩ dumping resistance, dI/dt is very higher than MQXF one. Question: do dynamic effects affect the decay with smaller dumping resistance? If yes, how much conservative have we been?

  4. 1.3 Residual bronze after reaction MQXF MIITs Considering bronze, at given MIITS we have ~30 K less in hot spot temperature

  5. 1.3 Summary Impact of the material properties uncertainty on the MIITs-T curve Analysis of HQ PH test with no dumping resistance Analysis of HQ PH tests with 5 mΩ dumping resistance (dI/dt similar to MQXF one) Coils resistance measurement during a discharge MQXF protection with IL-HF block PH

  6. Impact of the material properties uncertainty on the MIITs-T curve

  7. 2.1 Material properties impact • At given temperature, 1 MIITsdifference • At given MIITs, 30 K temperature difference Comparison between MIITs calculated by QMIITs (Tiinasalmi) with CRYCOMP/NIST and MATPRO database Non negligible uncertainty! Question: what are the right material properties? Temperature measurement needed to answer

  8. Analysis of HQ PH tests with no dumping resistance

  9. 3.1 Introduction • MQXF current decay is dominated by coils resistance A good understanding of the quench heaters simulation is important An analysis of HQ02 heaters test is in progress • OL heaters manual trips • No dumping resistance • Currents from 0.4 to 0.8 of SSL • Simulations with the same assumptions made for the MQXF Question to answer: How much conservative are the MQXF simulations?

  10. 3.2 Current decay comparison • 14.6 kA @ 1.9 K (0.8 of SSL) • OL-PH firing at 0 ms • No dumping resistance • Heaters delay time from TiinaSalmi simulations by CoHDA (Code for Heater Delay Analysis) (heat equation solving) • Heaters-induced quench covers all the turns, except the top and the bottom ones • Simulation using nominal inductance (5.8 mH) The average of the simulated delays in the HF/LF block is used as delay time in QLASA • The simulated decay is very slower. MIITs are surely overestimated • At the start of the decay, the experimental curve is faster than expected

  11. 3.2 Current decay comparison Current starts to decay after few ms. Heaters do not induce quench so quickly (checked on voltage taps) Evidence of a “dark” resistance

  12. 3.2 Current decay comparison ms • Decay is compatible with a resistance between 2.5 and 3.5 mΩ • Expected resistance coming from bus, diodes, connections is <1mΩ • There is an unexplained resistance of 1.5/2.5 mΩ Could it be that this is the reason of the similarity between the MIITs developed during 5 mΩ dumping resistance and no dumping resistance tests?

  13. 3.2 Current decay comparison

  14. 3.2 Current decay comparison Simulation repeated with a 3 mΩdumping resistance, in order to simulate the “dark” resistance Ideal for giving a more accurate MIITs estimation • Simulation with dumping resistance fits better at the start of the decay • Nonetheless, simulated current decay is still slower than experimental one

  15. 3.2 Current decay comparison Same analysis, on a 7kA test (0.4 of SSL) • The resistance is overestimated when heaters induce quench (curve with resistance) • This is due to the fact that at low current quench is induced only in few turns, therefore the assumption made (quench not induced only in the top and the bottom turn) is wrong in this case. In fact, in CoHDA simulation, 8 out of 26 OL turns  did not quench, but QLASA uses an average delay among all the turns

  16. 3.3 MIITs comparison and conclusions Most significant case for MQXF • Under the assumptions used for MQXF, the heaters-induced quench simulation is conservative. • At the current of interest (0.8 of SSL), the MIITs are overestimated of about 13 %. The overestimation is lower at lower currents. • An unexplained ~ 2/3mΩresistance appears during tests with no dumping resistance. This could be the reason of the similarity between MIITs developed during tests with no dumping resistance and tests with a 5 mΩresistance.

  17. 3.3 MIITs comparison and conclusions In MQXF, a MIITs overestimation of ~10% at 350 K corresponds to about 50 K less in hot spot temperature!

  18. Analysis of HQ PH tests with 5mΩ dumping resistance

  19. 4.1 Current decay comparison • 14.6 kA @ 1.9 K (0.8 of SSL) • OL heaters in protection • Heaters delay time from CoHDA (Tiinasalmi) Same program and assumptions used for MQXF • The current decay is slower in the simulation • The dynamic effects are still considerable (see start of the decay) with a dI/dt similar to MQXF one

  20. 4.2 MIITs comparison and conclusions Most significant case for MQXF • Conclusions: • In the most significant case for MQXF, MIITs are overestimated of ~16%, with the same assumptions made for MQXF on the heaters delay time, and with a similar dI/dt. • At 350 K, this overestimation corresponds to 80 K less in hot spot temperature • At lower current the overestimation is lower, but these cases are not relevant for MQXF

  21. Resistance growth measurement

  22. 5.1 Introduction • A current decay depends on the ratio between magnet inductance and resistance (coils plus eventual dumping resistance). • During the discharge, the inductance value appears lower than expected (fact experimentally proved), because of some dI/dt effects. • This effects are not yet predictable, so we’re using nominal inductance in simulations. The results are conservative. In order to answer, we’ve measured the coils resistance during the discharge. Then, experimental data have be compared to the simulated resistance growth. This measurement allows measuring theinductance. Question: in the case of negligibledI/dt effects in MQXF, are we still conservative? Is the coils resistance growth simulation conservative?

  23. 5.2 Resistance plot After dumping resistance (80 ms), data are unusable Heaters-induced quench start: 35-40 ms

  24. 5.3 Comparison Quench induced in all the turns, except the bottom and the top of the OL • Using delay time by Tiina simulations with CoHDA (same assumptions made for MQXF) the resistance growth is not conservative! • Anyway, we are analyzing test at 0.5 of SSL, therefore this result is not reliable for MQXF.

  25. 5.4 Conclusions • Simulated resistance growth is not conservative, using the same assumptions made for MQXF. • Anyway, these results are not reliable for MQXF, because they are at 0.5 of SSL current. • These kind of test seems interesting for future studies, such as a similar analysis at 0.8 of SSL current (MQXF similar case), or for checking the differences between the heaters effect on different coils. • This kind of test could be used also for measuring inductance during the discharge

  26. 5.4 Conclusions + Unfortunately, the “dark” resistance makes this measure unreliable. Anyway, results seem consistent with the nominal inductance value (~6mΩ)

  27. MQXF protection with IL-HF block PH

  28. 6.1 PH in the IL – HF zone • OL Heaters delay time: 17 ms (HF block, from CoHDA) • Validation time: 10 ms • Dumping resistance: 46 mΩ(800 V) • Voltage threshold: 100 mV • Bronze fraction: 30% of Cu/NCu • Two magnets (16 m) per dumping resistance

  29. 6.2 PH in the IL – HF zone What’s the impact of protection heaters in the inner layer (only high-field zone) on the hot spot temperature? Only OL PH case 332.7 K • Four cases considered: • Quench induced in the IL high-field block at the same time of the OL high- field block (average from CoHDA) • Quench induced in the IL high-field block 3 ms before the OL high-field block (average from CoHDA) • Quench induced in the IL high-field turn at the same time of the OL high-field block (average from CoHDA) • Quench induced in the IL high-field turn 3 ms before the OL high-field block (average from CoHDA) 305.6 K 8.9 % less 299.5 K 11.1 % less 310.4 K 7.2 % less 306.1 K 8.7 % less

  30. 6.3 Conclusions • Considering protection heaters on the inner layer (only in the high field zone), causes a drop in temperature of 20-30 K • The temperature difference between considering quench induced in the whole IL-HF block, or only in the IL-HF turn, is only of 5 K. • The temperature difference between considering the whole IL-HF block or turn to quench at the same time of the OL-HF, or 3 ms before, is only of 5 K. We could consider the idea of protection heaters on the inner layer, high-field block. It could be enough only on the high-field turn. Question to answer: What’s the impact of the bubbles caused by helium evaporation?

  31. Conclusions

  32. 7.1 Conclusions and improvements • Material properties strongly affect the MIITs-T curve, and therefore the hot spot temperature estimation at given MIITs. MATPRO (used by QLASA for MQXF) is the most conservative database between those considered (CRYOCOMP, NIST). • Tests with no dumping resistance show that, with the same assumptions made on the MQXF, we overestimate the MIITs of ~13%. It’s not clear how much this overestimation is due to dI/dt effects or to heaters delay time. We’ve also found an unexplained resistance in the circuit. • Tests with 5 mΩ dumping resistance (dI/dt similar to MQXF one) show that we overestimate the MIITs of ~16%, that means 80 K less in hot spot temperature. • We’ve been able to measure the coils resistance during a discharge. We’ve found that assumptions made for MQXF are not conservative at 0.5 of SSL. • Considering residual bronze after reaction causes a drop of 30 K in the hot spot temperature estimation • Considering heaters on the IL-HF zone causes a drop of 20-30 K in the hot spot temperature estimation • Possible improvements: • Simulation of eddy currents in the cryostat, aiming to predict the dI/dt effects in MQXF • Repeating a resistance growth measurement at higher current (0.8 of SSL), and with a known circuit resistance in order to measure also the inductance

  33. A.1 Copper magneto-resistance

  34. A.2 The measure 4 1 • Manual trip of the OL heaters, but only in two coils (opposite coils have been chosen, for mechanical reasons) 2 3 • Voltage measure between the ends of the four coils. In the two coils where the quench has been induced, the signal is resistive plus inductive, in the other two it’s only inductive. • Under the hypothesis of identic coils, by means of the difference between the two kind of signals, you can extract the resistive signal, and therefore the resistance Inconvenient: this measure can be done only at low current, for protection reasons, and for preventing development of quench in the coils not covered by heaters. For protection reason, a 60 mΩdumping resistance is used after 80 ms.

  35. A.3 Data analysis Because of acquisition problems, data are available only for two coils (unfortunately two opposite coils). Therefore the analysis is based on two tests, one with quenched coils, one with no quenched coils. The current decay is almost coincident, so the approximation is very good Resistive voltage growth is not equal in the two coils . Quench heaters act differently (verified with voltage taps check) Current of 8.2 kA at 4.6 K, 0.5 of SSL

  36. A.4 Comparison In simulations, I’ve made some different assumptions on heaters delaytime and heaters-induced quench size at the start About heaters delay time, I’ve used two values: Experimental quench start (35-40 ms) Time at which quench reaches a voltage of 1V (47-52 ms). This voltage corresponds to the simulated voltage between the coil ends after 2 ms. This is because, in the simulation, quench starts suddenly in several turns, instead in the actual case the quench start is distributed along the time. About quench initial size, I’ve analyzed three cases: Quench is induced in all the turns, except the top and the bottom turn of the OL (case similar to MQXF one). Quench is induced in all the turns, except the three top and the three bottom turns of the OL Quench is induced only in the high-field turn of the OL Simulations have been done for the cases with no dumping resistance and with 3 mΩdumping resistance

  37. A.5 Comparison • The simulations with the experimental delay overestimate the resistance. • The simulations with 1V delay are more conservative, but only the “1 turn quench” case is conservative, respect to experimental data. • Anyway, resistance growth at the very start of the quench is always faster in the simulations. Only the “1 turn quench” case is comparable.

  38. A.6 Comparison Results with the 3 mΩdumping resistance are similar

More Related