1 / 15

Inventory Update on RD-50 Silicon Sensors

Inventory Update on RD-50 Silicon Sensors. Jeff Wiseman 6-15-09. Sets of Sensors. 37 Total Boxes Last year 23 Boxes (22 at SU, 1 at FNAL) All boxes at SU had IV tests 19 of 22 boxes at SU had CV tests This year 14 New Boxes 7 N on N Boxes (No IV tests done yet)

ayame
Télécharger la présentation

Inventory Update on RD-50 Silicon Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Inventory Update on RD-50 Silicon Sensors Jeff Wiseman 6-15-09

  2. Sets of Sensors • 37 Total Boxes • Last year • 23 Boxes (22 at SU, 1 at FNAL) • All boxes at SU had IV tests • 19 of 22 boxes at SU had CV tests • This year • 14 New Boxes • 7 N on N Boxes (No IV tests done yet) • 7 N on P Boxes (5 Boxes of IV tests done) • A completed box in this case will be a box that has had the IV test done on it, all new boxes have not had CV test done on them

  3. Inventory by Growth Method • FZ (15 Total) • 12 Boxes Complete • 2 Boxes Incomplete • 1 Box at FNAL • FZN (1 Total) • 1 Box Complete • MCZ (21 Total) • 16 Boxes Complete • 5 Boxes Incomplete

  4. Inventory by Doping Type • P-Type (28 Total) • 18 Boxes Complete • 9 Boxes Incomplete • 1 Box at FNAL • N-Type (9 Total) • 9 Boxes Complete

  5. 2551 (6 Total) 5 Boxes Complete 1 at FNAL 2552 (12 Total) 7 Boxes Complete 5 Boxes Incomplete 2553 (4 Total) 4 Boxes Complete 2535 (6 Total) 6 Boxes Complete 2615 (2 Total) 2 Boxes Complete 2684 (5 Total) 3 Boxes Complete 2 Boxes Incomplete 2446 (2 Total) 0 Boxes Complete 2 Boxes Incomplete Inventory by Boxes

  6. Vbias Ground IV Measurements • Placement of the high voltage probe is on the bias ring • Placement of the low voltage probe is on the rubber pad Circuit #1 Guard Ring Bias Ring

  7. Old IV Curve

  8. More Recent IV Curve

  9. Depletion Voltages • Depletion voltages are taken from the CV measurements • Not all of the boxes have been tested • Following slides will have histograms of the depletion voltages split up by box, silicon method, and doping • All are scaled to the same voltages, so the comparison between everything can be seen

  10. Plans • Continue testing new sensors with both IV and later CV • Investigate odd readings by testing sensors with and without rubber pad • Start RD-50 Sensor Report, research information as needed

More Related