An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of Resistive Plate Chamber for charge particle detection Suryanarayan Dash Under the guidance of Prof N K Mondal TIFR,Mumbai

  2. Objectives: • Introduction • Main feature of RPC • RPC Fabrication • RPC Theory & Operation • Laboratory test set-up • Analysis of results

  3. Introduction Detectors:Searching for new particles To study their interaction • RPC the Resistive Plate Chamber detector was introduced in 1981 • Works on the principles of ionization of gas molecules to detect tracks of charge particles

  4. Main feature • Very large pulse height • Reduced cost per unit area • Easy fabrication and operation • Simple readout electronics • Good timing capability ,resolution is of the order of few ns

  5. Components of glass RPC : • Pair of float glass with resistivity 1012 Ω cm with 2 mm thick • 2 mm spacers • Gas mixture (typically Ar 30%,Freon 62%,isobutane 8%) • Ar: low cost,high specific ionization • Freon:high electron affinity • Isobutane:quencher • Gas nozzles • Graphite coating (good glass adhesion) for HV supply.

  6.   After graphite coating the surface resistivity 200-400 kΏ/ Finished RPC Frame

  7. Equivalent circuit of glass RPC

  8. RPC principles of operation μ Pulse height ~100 mV

  9. Laboratory test set-up with basic circuit

  10. Efficiency of RPC

  11. Typical TDC distribution

  12. Time resolution

  13. Typical ADC distribution

  14. Summary: • The time resolution of the present RPC ~1.8 ns at 9 kV • The efficiency of our present detector: 90% at 9 kV • Wide acceptance in HEP and Astroparticle community

  15. Thanks a lot .