1 / 23

Nunziante Squeglia, Lo Presti Diego, Barbara Cosanti

WORKSHOP ON PENETRATION TESTING 9 OCTOBER 2014 AUDITIORIUM OPERA PRIMAZIALE. Re – evaluation of classification charts for CPTU in partially saturated loose silt mixtures. Nunziante Squeglia, Lo Presti Diego, Barbara Cosanti. UNIVERSITA ’ DI PISA

Télécharger la présentation

Nunziante Squeglia, Lo Presti Diego, Barbara Cosanti

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. WORKSHOP ON PENETRATION TESTING 9 OCTOBER 2014 AUDITIORIUM OPERA PRIMAZIALE Re – evaluation of classification charts for CPTU in partially saturated loose silt mixtures Nunziante Squeglia, Lo Presti Diego, Barbara Cosanti UNIVERSITA’ DI PISA Dipartimento di Ingegneria dell’Energia, dei Sistemi del Territorio e delle Costruzioni squeglia@ing.unipi.it

  2. MOTIVATIONS SBT CLASSIFICATION CHARTS DO NOT CORRECTLY WORK IN CASE OF: PARTIALLY SATURATED SOILS LOOSE SILT MIXTURES

  3. PARTIALLY SATURATED SOILS EXAMPLE BRONI (PV) SITE Fine grained soil

  4. POSSIBLE CORRECTION EVALUATE SUCTION and CORRECT EFFECTIVE STRESS ADOPTED MODEL MK – KOVACS (Aubertin et al., 2003) granular soil f(D10, CU) fine soil f(LL)

  5. EFFECT OF CORRECTION (Ic): - BRONI

  6. ROBERTSON & CAMPANELLA (1986)ROBERTSON (1990)

  7. EFFECT OF CORRECTION (SBT): BRONI

  8. EFFECT OF CORRECTION (SBT): BRONI

  9. LOOSE SILTY MIXTURES: Qc < 1 MPa

  10. SERCHIO RIVER EMBANKMENTS

  11. Ic FROM BOREHOLES VS. Ic FROM CPTU

  12. Ic FROM BOREHOLES & CPTU

  13. EFFECT OF CORRECTION

  14. EFFECT OF CORRECTION

  15. HOW TO DISTINGUISH LOOSE SILT MIXTURES FROM COMPRESSIBLE CLAYS ETC. COMPRESSIBLE CLAYS, PEATS, ETC. CAN HAVE qc < 1 MPa MAY FR GIVE USEFUL INDICATIONS? FRICTION RATIO < 4?

  16. COMPRESSIBLE CLAYS: PISA EST

  17. COMPRESSIBLE CLAYS: PISA WEST

  18. COMPRESSIBLE CLAYS: PISA DISTRICT

  19. COMPRESSIBLE CLAYS: LIVORNO DISTRICT

  20. COMPRESSIBLE CLAYS: LUCCA DISTRICT

  21. COMPRESSIBLE CLAYS: PRATO DISTRICT

  22. EFFECT OF SLEEVE DIAMETER (HOSKIN ET AL., 2014)(NZ - SANDS)

  23. ACKNOWLEDGEMENTS CPT DATA IN TUSCANY HAVE BEEN PROVIDED BY GEOSERVIZI (COSCO & SPADARO) CPT INTERPRETATION HAS BEEN CARRIED OUT BY SCARDIGLI & ZACCAGNINO (UNDERGRADUATER STUDENTS) CPT DATA FROM BRONI HAVE BEEN GIVEN BY PAGANI AND DR. MEISINA (UNIPV) CPT INTERPRETATION OF BRONI DATA HAS BEEN CARRIED OUT BY ROSIGNOLI (GRADUATE STUDENT)

More Related