1 / 25

Post-Tensioning in Building Construction

Post-Tensioning in Building Construction. Examples of Post-Tensioned Building Construction. Constructed with Unbonded Post-Tensioning. Daniel Burnham Court, San Francisco. CONSTRUCTED WITH UNBONDED POST- TENSIONING. Red Lion Inn. Xerox Center, Santa Ana, California.

Télécharger la présentation

Post-Tensioning in Building Construction

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Post-Tensioning in Building Construction

  2. Examplesof Post-Tensioned Building Construction

  3. Constructed with Unbonded Post-Tensioning Daniel Burnham Court, San Francisco

  4. CONSTRUCTED WITH UNBONDED POST- TENSIONING Red Lion Inn

  5. Xerox Center, Santa Ana, California Lakeshore Tower, Irvine, California La Palma Center, La Palma, California EXAMPLES OF POST-TENSIONING PARKING STRUCTURES

  6. Constructed with Unbonded Post-Tensioning University of California Medical Center, Irvine

  7. CONSTRUCTED WITH UNBONDED POST TENSIONING San Jose International Airport

  8. POST-TENSIONED CONSTRUCTION WITH UNBONDED TENDON Cal-State Northridge C.I.P. Parking Structure

  9. POST-TENSIONED CONCRETE FLOOR SUPPORTING STEEL FRAME OFFICE BUILDING Hybrid Construction

  10. BASE PLATES FOR COLUMNS TERMINATING ON PT SLAB

  11. POST-TENSIONED HYPRID CONSTRUCTION Irwin Plaza, San Rafael, California

  12. VIEW OF THE PARKING LEVEL OF A HYPRID CONSTRTUCTION Irwin Plaza, San Rafael, California

  13. POST-TENSIONED MAT FOUNDATION Fortaleza, Brazil

  14. POST-TENSIONED MAT FOUNDATION Kodak Building, San Jose

  15. POST-TENSIONED GROUND SUPPORTED SLAB READY FOR CONCRETE POUR

  16. UNITED STATES POST-TENSIONING STEEL TONNAGE 1999 STATISTICS Buildings 33 % Bridges 17 % Ground supported slabs 43 % Earthwork 6% Miscellaneous 1 % ____________________________________ Total 100%

  17. ADVANTAGES OF POST-TENSIONING • Longer clear spans • Thinner slabs • Lesser floor-to-floor heights • Shorter building height • Lesser weight • Improved seismic performance • Faster construction cycle

  18. Post-Tensioning • System • Unbonded • Grouted (Bonded)

  19. ARRANGEMENT OF UNBONDED POST-TENSIONING SYSTEM

  20. COMPONENTS OF A GENERIC 12 mm (1/2 in.) STRAND TENDON

  21. HARDWARE FOR CORROSIVE ENVIRONMENT

  22. ASSEMBLED ANCHOR DEVICE FOR CORROSIVE ENVIRONMENT

  23. LIVE (STRESSING) ENDS AT SLAB EDGE

  24. UNBONDED POST-TENSIONING CONSTRUCTION High Rise Building 3rd Street San Francisco

  25. UNBONDED POST-TENSIONING CONSTRUCTION Red Lion Inn Hotel Modesto, California

More Related