1 / 16

POTENTIAL OF CARBON DIOXIDE COMPRESSOR TECHNOLOGY FOR REFRIGERATION APPLIANCES

POTENTIAL OF CARBON DIOXIDE COMPRESSOR TECHNOLOGY FOR REFRIGERATION APPLIANCES. Outline. New Applications for an Old Refrigerant Making CO 2 Refrigeration Technology Feasible Performance Assessment and Perspectives Preliminary Results from Appliances Tests Closure.

cady
Télécharger la présentation

POTENTIAL OF CARBON DIOXIDE COMPRESSOR TECHNOLOGY FOR REFRIGERATION APPLIANCES

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. POTENTIAL OF CARBON DIOXIDE COMPRESSOR TECHNOLOGY FOR REFRIGERATION APPLIANCES

  2. Outline • New Applications for an Old Refrigerant • Making CO2 Refrigeration Technology Feasible • Performance Assessment and Perspectives • Preliminary Results from Appliances Tests • Closure

  3. New Applications for an Old Refrigerant Usage in the Past CO2 Refrigeration advertisement in a business magazine in 1921: “1 to 150 tons in single units” “The ideal equipment for Refrigeration purposes” “Carbonic Safety System” Source: South Central Library System’s website

  4. New Applications for an Old Refrigerant CO2 Replacement - CFCs Era Begins CFC granted patent by Thomas Midgley in 1931: “...a process of heat transfer in which these desirable properties, such as non-flammability and non-toxicity, are obtained in combination with the desired boiling point.” Source: United States Patent Trade Office

  5. New Applications for an Old Refrigerant CO2 Revival • Reasons: • International regulations on HFCs • Lack of long term solutions for refrigerant fluids • Environmental consciousness • “Ecological appeal” • Market demand • ApplicationsEnvisioned: • Automobile Air-Conditioning • Heat Pump Water Supply Systems • Light Commercial Refrigeration (Beverage Cooling, Ice Cream Freezing, ... )

  6. Making CO2 Refrigeration Technology Feasible Refrigeration Means with Practical Use • Vapor Compression • Vapor Absorption • Air-Cycle • Solid State (Thermo-Electric, ...) • High Efficiency • Low Cost • Better Cost-to-Benefit Ratio • Simple Mechanical Embodiments ”...the refrigerating effect is produced by making a volatile fluid boil at a suitably low temperature...”

  7. Making CO2 Refrigeration Technology Feasible Vapor Compression Systems

  8. Making CO2 Refrigeration Technology Feasible Refrigeration Cycle Inefficiency Typical conditions for MBP Application

  9. Direct Effect GWP - Refrigerant Global Warming Potential [kgCO2/kg] L - Annual Leakage Rate [kg/year] n - Life time [years] m - Refrigerant charge [kg]  - Recycling factor [%] • Indirect Effect E - Annual energy consumption [kWh/year]  - CO2 emissions on energy generation [kgCO2/kWh] Making CO2 Refrigeration Technology Feasible TEWI Methodology

  10. 32oC Ambient Temperature 65% Relative Humidity Making CO2 Refrigeration Technology Feasible Overcoming Inefficiency of the CO2 Refrigeration Cycle

  11. Performance Assessment and Perspectives Phase I: CO2-Oriented Compressor Design

  12. Performance Assessment and Perspectives Phase II: CO2-Optimized Compressor Design

  13. Performance Assessment and Perspectives Compressor Data - Baseline and Benchmark

  14. 32oC Ambient Temperature 65% Relative Humidity Preliminary Results from Appliance Tests Beverage Cooling - 405 Cans Vending Machine

  15. Closure Concluding Remarks • All the comments stated below take into account HFC technology currently in the field, without considering any improvement on it; • Replacing current HFC refrigerant fluids by CO2 is meaningful only if the overall energy consumption is at least at the same level of the respective baseline; • Theoretical CO2 refrigeration cycles point to efficiencies lower than their respective HFC cycles; the higher the ambient temperature the higher the penalty in efficiency is; • In real applications, optimized CO2 compressors can deliver better compression and volumetric efficiencies than current HFC compressors; • Superior compression and volumetric efficiencies can make the CO2 application feasible, overcoming the intrinsically low cycle efficiency; • Preliminary results from an appliance testing employing optimized CO2 compressors have pointed to competitive performance in terms of energy consumption;

  16. QUESTIONS ? Contact Information: Ricardo Maciel EMBRACO - Empresa Brasileira de Compressores SA Rui Barbosa 1020 - Costa e Silva Joinville - SC - Brazil Phone: +55 47 441.2762 Fax: +55 47 441.2650 email: ricardo_a_maciel@embraco.com.br

More Related