1 / 15

Joint submission for Box 5 calibration

This joint submission provides updated simulation results for Box-5 calibration, focusing on 1 BSS UL case. However, the results are not yet matched. Detail implementations were agreed upon to speed up the calibration process.

caffee
Télécharger la présentation

Joint submission for Box 5 calibration

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Joint submission for Box 5 calibration Date: 2015-05-14 Authors: Suhwook Kim, LG Electronics

  2. Suhwook Kim, LG Electronics

  3. Abstract • This joint submission provides updated simulation results for Box-5 calibration of each members • However, the results are not matched yet • To speed up the Box-5 calibration, we agreed some detail implementations Suhwook Kim, LG Electronics

  4. Box-5 Calibration [1] • Box 0, 1, and 2 calibration are almost done • Box 3 calibration is now in progress • Box 5 calibration was initially discussed in September meeting • Box 5: Integrated system simulator calibration • The objective is to align a combination of all PHY and MAC features Suhwook Kim, LG Electronics

  5. Box-5 PHY Details [2] Suhwook Kim, LG Electronics

  6. Box-5 MAC Details [2] Suhwook Kim, LG Electronics

  7. 11ac Scenario 6 – OBSS Enterprise [2][3] Fixed Location and Association Suhwook Kim, LG Electronics

  8. History on Box-5 Calibration • We have discussed Box-5 calibration from September meeting • Many issues have been agreed and addressed in DCN 1523r5 • Simulator members agreed that we have to focus on 1 BSS UL case in March meeting (BSS B) Suhwook Kim, LG Electronics

  9. Focusing case • No shadowing • Fixed MCS = 5 instead of 7 currently used • Firstly calibrate 3 combinations of 2-STA case (3+9, 3+27, 3+15) • Then we turn to 3-STA case (3+9+27, 3+9+15) Suhwook Kim, LG Electronics

  10. One BSS Test Result • Each STA Throughput [Mbps] Suhwook Kim, LG Electronics

  11. One BSS Test Result • Sum Throughput [Mbps] Suhwook Kim, LG Electronics

  12. Agreement during off-line discussion • Each members make sure own simulator about following issues and specify among this group • Power Spectral density (scale to 80 MHz) • Preamble decoding procedure (EMD 571r8)[9] • Capture window size, preemption window size, etc.. • Each single link performance (STA-AP 1-to-1) • A-MPDU aggregation algorithm Suhwook Kim, LG Electronics

  13. Agreement during off-line discussion • Running time: at least 10 seconds per 1 drop • No capture effect: Receiver is locked during PPDU length • UDP traffic starts during 1.000 ~ 1.010 seconds • Additional performance metrics may be used • PER • 1 - # of success subframes / # of transmitted subframes • Average number of aggregated subframe • # of transmitted subframes / # of transmitted PPDU Suhwook Kim, LG Electronics

  14. Conclusion • This joint submission provided simulation results for Box-5 calibration of each members • We focused 1 BSS UL case • However, the results are not matched yet • To speed up the Box-5 calibration, we agreed some detail implementations • Text for Simulation Scenario Document (980r10) will be presented Suhwook Kim, LG Electronics

  15. Reference • [1] 11-14/0571r5 Evaluation Methodology • [2] 11-14/1177r2 Box5 Calibration Discussion • [3] 11-09/0451r16 TGac Functional Requirements and Evaluation Methodology • [4] 11-14/1523r5 Offline Discussion Minutes of SLS Calibration • [5] 11-14/1392r7 Simulation Results for Box5 calibration • [6] 11-15/0638r1 Simulation Results for Box5 • [7] 11-15/0613r0 Box 5 Calibration Result • [8] 11-15/0610r1 Simulation Results for Box 5 Calibration • [9] 11-14/0571r8 Evaluation Methodology Suhwook Kim, LG Electronics

More Related