Gamma-ray Large Area Space Telescope. GLAST Large Area Telescope. GLAST Large Area Telescope. LAT Level Requirement Sell-off Package for LVP159/LPS598 – DC Voltage Tolerance Requirement Owner: David Nelson Approval Date: Approved By: LAT Docs No: LAT-MD-08398.

casper
Télécharger la présentation

GLAST Large Area Telescope

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Gamma-ray Large Area Space Telescope GLAST Large Area Telescope GLAST Large Area Telescope LAT Level Requirement Sell-off Package for LVP159/LPS598 – DC Voltage Tolerance Requirement Owner: David Nelson Approval Date: Approved By: LAT Docs No: LAT-MD-08398

  2. LVP159/LPS598 – DC Voltage Tolerance • Requirement: The LAT shall tolerate without damage or degradation DC voltages greater than 15.0 volts and less than 40.0 volts. • Verification Method: A5 • Verification Plan: • 1) This requirement has a waiver submitted to NASA. This analysis sets the minimum voltage to 18.5 volts. The CCR number is 433-0357. • 2) Analysis will show that all of the components are rated for 40 volt operation. • Test Script Run Info: • Worst Case Measured Data: N/A • Margin: N/A • Test/Analysis Summary: Analysis shows that the minimum voltage is 18.5 volts. All subsystem assemblies are rated to 40 volts.

  3. LVP159/LPS598 – DC Voltage Tolerance • Analysis Report/Test Report Doc #(s): • CCR # 433-0357 is the analysis for 18.5 volt operation. • The 40 volt operation was successfully tested on each of the following subassemblies: • Tower Power Supply, LAT-DS-01482 • The test procedure for the Tower Power Supply is LAT-TD-01652 paragraph 5.5.2-6 • Crate Power Supply, LAT-DS-02390 • The test procedure for the Crate Power Supply is LAT-TD_01673 paragraph 5.4.1-35 • GASU Power Supply, LAT-DS-02413 • The test procedure for the GASU/ACD Power Supply is LAT-TD_01727 paragraph 5.4.1-36 • The PDU 40 volt compliance is by analysis. • The PDU Assembly schematic diagram is LAT-DS-01696. • The PDU CCA schematic is LAT-DS-02127. • LAT-DS-02127 sheet 6 of 66, PDU_3_3_V_PS is the schematic of the 28V to 3.3V power converter. • There is a series of capacitors, C42-C47 & C49 which is rated at 50V • An input filter, ARF461 which is rated at 80 volts. • http://www.irf.com/product-info/datasheets/hirel/arf461.pdf • A DC-DC converter, MAX-724, rated at maximum of 45 volts • http://pdfserv.maxim-ic.com/en/ds/MAX724-MAX726.pdf • Two power FETs are used to switch spacecraft power to loads are rated at 60V • http://www.irf.com/product-info/datasheets/data/irhna597064.pdf • http://www.irf.com/product-info/datasheets/data/irhnj597034.pdf • All wire used is MIL-W-22759 rated at 600V

  4. LVP159/LPS598 – DC Voltage Tolerance • Compliance Statement: LAT Complies • NCRs/JIRAs: None