1 / 18

11 C background suppression in the CNO-pep solar neutrino energy region with Borexino

11 C background suppression in the CNO-pep solar neutrino energy region with Borexino. XCIV Congresso Nazionale della Società Italiana di Fisica 22-27 Settembre 2008, Genova. Davide Franco for the Borexino collaboration Milano University & INFN. pep and CNO neutrinos. pep neutrinos:

cera
Télécharger la présentation

11 C background suppression in the CNO-pep solar neutrino energy region with Borexino

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 11C background suppression in the CNO-pep solar neutrino energy region with Borexino XCIV Congresso Nazionale della Società Italiana di Fisica 22-27 Settembre 2008, Genova Davide Franco for the Borexino collaboration Milano University & INFN

  2. pep and CNO neutrinos • pep neutrinos: • Directly related with thepp fusion reaction in the Sun • Improves our knowledge of the solar neutrino luminosity • Test of the MSW-LMA • CNO neutrinos: • First experimental observation of the CNO cycle presence in the Sun • Helpful in the age estimation of the Globular Clusters • Non-standard interactions, mass-varying neutrinos, CPT… Davide Franco – Università di Milano & INFN

  3. Events/3years/100 tons/0.05 MeV Detection signature in Borexino • Neutrino elastic scattering off electrons • Energy range of observation: • 0.8 – 1.4 MeV • Expected flux in BOREXino-like scintillator (BS07++LMA): • pep-n: 9x10-3 d-1 ton-1 • CNO-n: 6x10-3 d-1 ton-1 3 years statistics in 100 tons of scintillator Overall signal rate: 1.5 c/d in 100 tons Davide Franco – Università di Milano & INFN

  4. Detector layout and main features Stainless Steel Sphere: 2212 PMTs 1350 m3 Scintillator: 270 t PC+PPO in a 150 mm thick nylon vessel Nylon vessels: Inner: 4.25 m Outer: 5.50 m Water Tank: g and n shield m water Č detector 208 PMTs in water 2100 m3 Carbon steel plates 20 legs Davide Franco – Università di Milano & INFN

  5. The signal and the background Energy range: 0.8 – 1.4 MeV 11C contamination Davide Franco – Università di Milano & INFN

  6. m (+ secondaries) + 12C → m (+ secondaries) + 11C + n n + p → d + g 11C → 11B + e+ + ne 11C production and the three-fold coincidence • Triple coincidence among: • cosmic muon: • rate at LNGS (3700 m.w.e.): 1.16 hr-1 m-2 • average energy: 320 GeV • gamma from neutron capture: • energy: 2.2 MeV • capture time: 250 ms • positron from 11C decay: • deposited energy between 1.022 and 1.982 MeV (but quenched!) • mean life: 30 min!!! m 11C n Davide Franco – Università di Milano & INFN

  7. m PC+PPO 11C n g Vetoing the detector Depends on detector efficiencies in tagging neutrons and in tagging and tracking muons Davide Franco – Università di Milano & INFN

  8. 11C expected rate from NA54 Cern experiment S/B ~1/6 Davide Franco – Università di Milano & INFN

  9. m are identified by ID and OD OD eff: ~ 99% ID based on pulse shape analysis Rejection factor > 103 (conservative) m crossing the buffer only m crossing the scintillator Detecting (and rejecting) cosmic muons m pulse scintillation pulse Rm = (1.21±0.05) h-1m-2 Davide Franco – Università di Milano & INFN

  10. m-track (in progress) Davide Franco – Università di Milano & INFN

  11. NA54 Kamioka LNGS C. Galbiati et al., Phys. Rev. C 71, 055805 (2005) Intrinsic inefficiency SNOLab Cross sections for 11C production from 12C as a function of energy SNOLab Cumulative range of m-induced secondaries Neutrons are produced in association with 95.5% of the muon-induced 11C Davide Franco – Università di Milano & INFN

  12. Muon induced neutrons • Since January 2008 we were unable to identify high-multiplicity events • Electronics has been properly modified: a very long gate (1.6 ms) is opened after each muon • New clustering algorithm has been developed • A parallel FADC multichannel system is under development to estimate the efficiency • From preliminary results > 90% neutrons detected • Still problems in very high multiplicity events Davide Franco – Università di Milano & INFN

  13. Test of the coincidence technique with the Counting Test Facility • 4 tons of scintillator • 1 m radius vessel housing the scintillator • 2 m radius “shroud” • 3.6 p.e./PMT for 1 MeV electron • Muon veto • 100 PMT (OC: 21%) • Buffer of water • Energy saturation: 6 MeV Davide Franco – Università di Milano & INFN

  14. Data selection in CTF • Muon selection • cut on the number of photoelectrons detected by the muon-veto • Neutron selection • For each detected m, the following event in the time window Tn = [20, 2000] μs is selected as a candidate event for a neutron capture γ • E < 2.6 MeV • 11C selection • After each m-g coincidence, 11C candidates are selected in a subsequent time window Tw = 300 min, 10 times the 11C mean life. • Optimal energy range: 1.15 < E < 2.25 MeV • Distance between 11C event and gamma < 35 cm Davide Franco – Università di Milano & INFN

  15. Measured Rate = 0.89 ± 0.20 Expected Rate(NA54) Measured 11C production rate in CTF Phys.Rev.C74:045805,2006. R(11C) = [13.0 ± 2.6(stat) ± 1.4(syst)]×10-2 d-1 ton-1 Goal reached? Davide Franco – Università di Milano & INFN

  16. Three Fold Coincidence in Borexino sample of 11C with strong cuts S = 500 ± 12 pe/MeV Q/E ~ 80 % • The total rate is not known yet: • Unknown efficiency in tagging neutrons • Too low statistics Davide Franco – Università di Milano & INFN

  17. Measured Rate = 1.7 ± 0.1 Expected Rate(NA54) …larger rate in Borexino from spectral analysis • Inconsistency between NA54/CTF and Borexino? • different size of the detector? • other background sources? Davide Franco – Università di Milano & INFN

  18. Conclusion • Electronics and DAQ have been properly modified and strongly improved • New FADC system for increasing the neutron detection efficiency is almost ready • The CTF measurement has demonstrated that the three-fold coincidence techniqueis powerful in localizing in space and time 11C decays • 11C can be removed by blinding detector volumes around it • Still problems: inconsistency between the rate measured by CTF and NA54 and Borexino • Waiting for more statistics pep and CNO neutrino spectroscopy is coming soon!! Davide Franco – Università di Milano & INFN