1 / 18

Jean-Pierre Brien Tim Dellapinna Ryan Faubert Michael Greencorn

Jean-Pierre Brien Tim Dellapinna Ryan Faubert Michael Greencorn. Introduction. Based on Dr. Basu’s Research which showed that bio-matter breaks down in supercritical water Design a portable supercritical water reactor to break down dangerous bio medical waste. Design Criteria.

Télécharger la présentation

Jean-Pierre Brien Tim Dellapinna Ryan Faubert Michael Greencorn

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Jean-Pierre Brien Tim Dellapinna Ryan Faubert Michael Greencorn

  2. Introduction • Based on Dr. Basu’s Research which showed that bio-matter breaks down in supercritical water • Design a portable supercritical water reactor to break down dangerous bio medical waste

  3. Design Criteria • The reactor will be designed such that pressure vessel certification will not apply. The design will follow pressure vessel codes regardless. • Adhere to all provincial regulations and codes • Adhere to ASME and relevant pressure vessel codes • Provisions for internal visibility • Generally safe and operational • Appearance creates awareness of its potential danger • Easily opened and closed reaction chamber • Portable

  4. Supercritical Water • Operating Conditions • 600°C • 25MPa

  5. Process Design

  6. Design Overview

  7. Reaction Vessel

  8. Flange

  9. Sight Glasses

  10. Valves

  11. Overflow Vessels

  12. Safety • Safety is paramount for this project • Extensive stress calculations have been conducted on reaction vessel • Safety factor of 3 for reaction vessel • Swagelok VCR fittings weakest point 30 Mpa maximum pressure • Temperature reduced before valves • Temperature and Pressure decreased before valve network and overflow vessels • A safety valve will ensure that if the BPV does fail the pressure in the vessel will never go critical

  13. Test Day • Used bubbling bed • Anaerobic Environment • Beef broken down into smaller molecules • Evidence of carbon residue • High pH water residue Where’s the beef?

  14. Heater • Bubbling bed • At least 20 Watts • At least 700°C • Reduced cost • No increased safety if the pressure vessel goes critical

  15. Instrumentation • Thermocouple • Omega Engineering Pressure Transducer

  16. Budget

  17. Got Beef? Any Questions?

More Related