1 / 77

Current Product Update

Current Product Update. Ray Reilly, Product Manager. Agenda. UL 864 Ninth Edition Update Discontinued Panels New Conventional Panels New Deluge and Agent Release Panels ONYX Series Update ONYX DVC Update Leveraging Ninth Edition As a Competitive Advantage. UL 864 Ninth Edition Update.

Télécharger la présentation

Current Product Update

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Current Product Update Ray Reilly, Product Manager

  2. Agenda • UL 864 Ninth Edition Update • Discontinued Panels • New Conventional Panels • New Deluge and Agent Release Panels • ONYX Series Update • ONYX DVC Update • Leveraging Ninth Edition As a Competitive Advantage

  3. UL 864 Ninth Edition Update • 4 Extensions so far • Effectivity date currently set for12/31/08 • Cycle time statistics (HFS wide) • Pre 9th Edition cycle time – 144 days • 9th Edition projects (CT engineering) • Average for completed projects – 346 days • Average for Intelligent Control panel – 420 days • Average for all projects assuming completion today ~490 days • partially due to re-prioritization

  4. UL 864 Ninth Edition Update • We believe NOTIFIER leads industry in UL 9th readiness • Addressable product lines listed • ONYX Series • NFS-320, NFS2-640, NFS2-3030 and NCA-2 • FireWarden Family • NFW2-100, NFW-50, NFV-25/50(ZS), NFV-250DA(ZS) • Audio / Voice Evacuation product lines listed • DVC Digital Audio Products • Legacy Audio Products • AA Series Amplifiers and XPIQ Products

  5. UL 864 Ninth Edition Update • Workstation products listed • ONYXWorks • NCS • New Conventional Panels • SFP-5UD Series • SFP-10UD Series • New Releasing Panels • RP-2001 Deluge/Preaction • RP-2002 Agent Release

  6. UL 864 Ninth Edition Update • Last 8th Edition product order dates • May 31, 2008 • AFP-200 • APS-6R • MPS-24A • November 30, 2007 • NFS-3030 (8th Edition) • NFS-640 (8th Edition) • RP-1001, RP-1002 • ACPS-2406

  7. Discontinued Panel NFS-640* NFS-3030* RP-1001* RP-2001* SFP-1024** Recommended Replacement NFS2-640 NFS2-3030 RP-2001 RP-2002 SFP-5UD/SFP-10UD Discontinued Products *Last order date is November 30, 2007 ** Discontinued as of August 2007

  8. NFS2-640 Basic Components CPU2-640 (includes chassis) KDM-R2 DP-DISP2 BMP-1 (2) BP2-4 NFS-640 Basic Components CPU-640 CHS-M2 PD-2 Includes KDM, DP-DISP and two BMP-1 BP-4 NFS2-640 vs. NFS-640

  9. NFS2-640 Built-in NACs 4 Ckts Style Y or Z 6 amps total 1.5 amp per ckt Synchronization SSD, WL, Gentex Panel Ckt Module Support No Use XP Series modules and ACS annunciators for control NFS-640 Built-in NACs 4 Ckts Style Y or Z 6 amps total 2.5 amp per ckt Synchronization SSD Panel Ckt Module Support Yes Up to 8 output modules with control switches NFS2-640 vs. NFS-640

  10. NFS2-640 Remote Annunciators FDU-80 LCD-80* ACS Series Battery Charge Capacity 18AH – 200AH Up to 26AH in cabinet Upload/Download Software Veri-Fire Tools USB or NUP connection USB requires Veri-Fire Tools version 4.5 or higher NFS-640 Remote Annunciators FDU-80 LCD-80, LCD-80TM ACS Series Battery Charge Capacity 12AH – 55AH Up to 26AH in cabinet Upload/Download Software Veri-Fire Tools NUP connection NFS2-640 vs. NFS-640 *LCD-80 being submitted for 9th edition listing

  11. NFS2-3030 Basic Components CPU2-3030D LCM’s/LEM’s CHS-M3 AMPS-24 DP-DISP BMP-1 (2) BP2-4 Backbox and Door NFS-3030 Basic Components CPU-3030D LCM’s/LEM’s CHS-M3 AMPS-24 DP-DISP BMP-1 (2) BP-4 Backbox and Door NFS2-3030 vs. NFS-3030

  12. NFS-3030 Panel Ckt Module Support Yes Up to 12 input/output modules with control switches Upload/Download Software Veri-Fire Tools NUP connection NFS2-3030 Panel Ckt Module Support No Use XP Series modules and ACS annunciators for control Upload/Download Software Veri-Fire Tools USB or NUP connection USB with version 11.2.4 or higher panel software and VeriFire Tools version 4.5 or higher NFS2-3030 vs. NFS-3030

  13. Discontinued Power Supply ACPS-2406* APS-6R** FCPS-24E* FCPS-24C* MPS-24A** Recommended Replacement ACPS-610 ACPS-610*** FCPS-24S6E/FCPS-24S8E FCPS-24S6C/FCPS-24S8C AMPS-24 Discontinued Products *Last order date is November 30, 2007 **Last order date is May 31, 2008 ***Alternative APS-6R replacement being developed

  14. Discontinued Products • Replacement Board and Repair Policy • NOTIFIER will support products beyond the warranty period with repair service, replacement boards or refurbished boards for as long components are commercially available from our suppliers

  15. AFP-200 Discontinuation Date • May 31, 2008 • The time to bid farewell to our “old” friend is approaching • NFS-320 is the replacement • ONYX Series • Supports Flashscan • Offers ONYX Intelligent Sensing • Designed for network applications • Flashable EEPROM • 18 – 200 AH battery charger

  16. New Conventional Panels • SFP-5UD • Five zone panel with built-in communicator • Four NACs • 3 amps total system power, 2.5 amp max per NAC • Models • SFP-5UD: 120 VAC, Black Backbox • SFP-5UDR: 120VAC, Red Backbox • SFP-5UDE: 240 VAC, Black Backbox

  17. New Conventional Panels • SFP-10UD (SFP-1024 Replacement) • Ten zone panel with built-in communicator • Four NACs • 7 amps total system power, 3.0 amp max per NAC • Models • SFP-10UD: 120 VAC, Black Backbox • SFP-10UDR: 120 VAC, Red Backbox • SFP-10UDE: 240 VAC

  18. SFP-5UD/10UD: Key Upgrades • 80-character LCD display (backlit) • Built-in Programmer • Extensive transient protection • New UL standard • Disable/Enable control per input zone and output zone • Compatible with System Sensor I3 Detectors • Transmits a maintenance trouble signal when detector needs cleaning • Transmits supervisory “freeze” signal when ambient temperature falls below 41 degrees Fahrenheit • With 2WT-B and 4WT-B only

  19. SFP-5UD/10UD: Key Upgrades • Four programmable Style Y (Class B) NACs • NACs programmable for: • Silence Inhibit • Auto-Silence • Strobe Synchronization • System Sensor, Wheelock, Gentex, Faraday or Amseco • Selective Silence (horn-strobe mute) • Temporal or Steady Signal • Silenceable or Nonsilenceable

  20. SFP-5UD/10UD: Key Upgrades • History log with 256 event storage • Real-time clock/calendar with daylight savings time control • Removable Terminal Blocks • Easier replacement and troubleshooting • Flashable EEPROM • Via the PPU Wizard

  21. Three programmable Form-C relays Resettable and non-resettable output power 2 Outputs, 500 mA each Control Buttons ACK (Acknowledge) Alarm Silence System Reset/Lamp Test Drill Indicators Fire Alarm Supervisory Trouble AC Power Alarm Silence SFP-5UD/10UD Product Features

  22. SFP-5UD/10UD Product Features • 24 volt operation • Low AC voltage sense • Integral supervised battery charger • 7 AH to 26 AH • Up to 18 AH in the FACP enclosure • 26 AH require BB-26 or NFS-LBB battery box

  23. SFP-5UD/10UD Product Features • Silent or audible walktest capabilities • Optional Dress Panel DP-51050 • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs • Optional 4XTMF Municipal Box Transmitter Module

  24. SFP-5UD/10UD Product Features • Common Enclosure • Allows easier wiring access with heavy gauge wire • Multiple knockouts • Hinged optional dress panel • Quick Remove Chassis • Two tabs and two bolts for easy replacement • Houses power supply and motherboard

  25. SFP-5UD/10UD Product Features • Programming Options • On-board keypad • USB programming port (future) • Release date TBD • Local Upload/Download (future) • Release date TBD • Remote Upload/Download (future) • Release date TBD

  26. SFP-5UD/10UD Product Features • ANN-BUS Optional Annunciator Devices • N-ANN-80 • 80-character remote LCD annunciator • N-ANN-S/PG • Provides connection to a serial or parallel printer • N-ANN-I/O • Graphic annunciator interface • N-ANN-LED/RLED (future, release date TBD) • Provides three leds per zone: alarm, trouble and supervisory • N-ANN-RLY (future, release date TBD) • Provides 10 form C relays

  27. RP-2001 Preaction and Deluge Panel • Deluge System • Designed for sprinkler standards NFPA 13, 15 and 16 • Replaces RP-1001(E) • Adjustable waterflow discharge timer and two soak timers • Cross-zone (double-interlock) capability

  28. RP-2002 Agent Release Panel • Clean Agent System • Designed for clean agent releasing standards NFPA 12, 12A, and 2001 • Replaces RP-1002(E) • Adjustable pre-discharge, discharge and waterflow delay timers • Cross-zone (double-interlock) capability • Programmable Abort operation

  29. RP-2001/RP-2002: Key Upgrades • Single or Dual Hazard Operation • Six programmable Style B (Class B) IDCs (Initiating Device Circuit) • Compatible with System Sensor I3 Series Smoke Detectors • Transmits a maintenance trouble signal when detector needs cleaning • Transmits supervisory “freeze” signal when ambient temperature falls below 41 degrees Fahrenheit • With 2WT-B and 4WT-B only

  30. RP-2001/RP-2002: Key Upgrades • Four Style Y (Class B) output circuits programmable for: • Releasing Solenoids • NACs programmable for: • Silence Inhibit • Auto-Silence • Strobe Synchronization • System Sensor, Wheelock, Gentex, Faraday or Amseco • Selective Silence (horn-strobe mute) • Temporal or Steady Signal • Silenceable or Nonsilenceable • Release Stage Sounder • 7.0 amps total 24 VDC output current

  31. RP-2001/RP-2002: Key Upgrades • 80-character LCD display (backlit) • Programmable from onboard keypad • Disable/Enable control per input zone and output zone • Real-time clock/calendar with daylight savings time control • History log with 256 event storage

  32. RP-2001/RP-2002: Key Upgrades • Integral supervised battery charger • 7 AH to 26 AH • Up to 18 AH in the FACP enclosure • 26 AH require BB-26 or NFS-LBB battery box

  33. RP-2001/RP-2002: Key Upgrades • Completely field programmable from the keypad • Pre-programmed application templates (RP-2001 - Deluge) • Single Hazard - 3 Zone • Single Hazard - Cross-Zone With Manual Release • Dual Hazard - Combined Release • Dual Hazard - Split Release • Single Hazard - 3 Zones and Low Pressure • Single Hazard - 2 Zones Cross-Zoned With All Active • Single Hazard - Dual Zone • Or – Create your own!

  34. RP-2001/RP-2002: Key Upgrades • Completely field programmable from the keypad • Pre-programmed application templates (RP-2002 - Agent) • Cross-Zone System - Zones 1 & 4: All Active • Single Zone System With Horn • Or – Create your own!

  35. RP-2001/RP-2002 Product Features • Any normally-open contact devices • Manual Pull Stations • Pressure Switches • Waterflow switches • Conventional 2-wire or 4-wire, 24 VDC smoke detectors • Resettable and non-resettable output power • 2 Outputs, 500 mA each • Extensive transient protection • Three programmable Form-C relays

  36. Control Buttons ACK (Acknowledge) Alarm Silence System Reset/Lamp Test Drill Indicators Fire Alarm Supervisory Trouble AC Power Alarm Silence Discharge Abort (RP-2002 only) RP-2001/RP-2002 Product Features

  37. RP-2001/RP-2002 Product Features • Piezo sounder for alarm, trouble and supervisory • 24 volt operation • Low AC voltage sense

  38. RP-2001/RP-2002 Product Features • Silent or audible walktest capabilities • Optional Dress Panel DP-51050 (red) • Optional N-CAC-5X Class A Converter Module for Outputs and IDCs • Optional 4XTM Municipal Box Transmitter Module • Optional Digital Alarm Communicators (411, 411UD, 411UDAC)

  39. RP-2001 and RP-2002 Product Features • ANN-BUS Optional Annunciator Devices • N-ANN-80 • 80-character remote LCD annunciator • N-ANN-S/PG • Provides connection to a serial or parallel printer • N-ANN-I/O • Graphic annunciator interface • N-ANN-LED/RLED (future, release date TBD) • Provides three leds per zone: alarm, trouble and supervisory • N-ANN-RLY (future, release date TBD) • Provides 10 form C relays NOTE: SFP-5UD, SFP-10UD, RP-2001 and RP-2002 use the same annunciator devices.

  40. ANN-BUS Devices N-ANN-80 Remote LCD N-ANN-I/O LED Driver N-ANN-S/PG Printer N-ANN-RLY Relay N-ANN-LED Annunciator Up to 8 – any mix

  41. ANN-BUS Devices • N-ANN-80 Remote LCD Annunciator • 80 character LCD • Mimics FACP display • Key switch controlled • Switches • Silence • Reset • Drill • Switches can be individually disabled • LEDs • AC Power • Trouble • Supervisory • Fire Alarm • Alarm Silenced • Mounts to single, double or 4” square electrical box.

  42. ANN-BUS Devices • N-ANN-I/O LED Driver • Provides up to 40 LED outputs • Used with custom graphic annunciators • http://www.ledinc.com/

  43. ANN-BUS Devices • N-ANN-S/PG Printer Module • Provides remote serial or parallel output • Connects to: • PRN-6 printer • PC (Hyper Terminal) • Any Serial/Parallel compatible device • Also used to “dump history”

  44. ANN-BUS Devices • N-ANN-RLY Relay Module (future, release date TBD) • 10 Individually Programmable Relays • 2.0 amps @ 30 VDC (resistive) • 0.5 amps @ 30 VAC (resistive) • Mounts Inside the FACP enclosure

  45. ANN-BUS Devices • N-ANN-LED Annunciator Module • Future, release date TBD • Provides LED annunciation of general system faults and input zones • Alarm (red) • Trouble (yellow) • Supervisory (yellow) • Supplied mounted to the DP-51050LED Dress Panel • Remote mount option • N-ANN-LEDBB (release date TBD)

  46. ONYX Series Update: NFS-320 • Current production Version 10.08.03 • Ability to disable/enable points or zones via ACS • Programmed via VeriFire Tools version 5.0 (or higher) • Fixed issue with the “Range” operator Logic Programming • Now MEA listed and FM approved • UL, ULC, CSFM • Serial interface to NFV-25/50ZS • Allows NFV-25/50ZS messages to be controlled via software zones • Successfully completed UL testing

  47. ONYX Series Update: NFS2-640 • Current production Version 10.08.03 • Ability to disable/enable points or zones via ACS • Programmed via VeriFire Tools version 5.0 (or higher) • Allows a NUP-to-NUP-to-NUP connection between CPU2-640, DVC (V2.0) and NCA-2 (V11.2.4) • Fixed issue with the “Range” operator Logic Programming • Now MEA listed and FM approved • UL, ULC, CSFM

  48. ONYX Series Update: NFS2-3030 • Current production version 11.2.4 on Magni-Fire • Allows On/Off Control of Software Zones • Local or network • Allows Zone Disable via Logic Zone • Local or network • ACS support for new DVC (V2.0) paging options • USB support (requires VeriFire Tools V5.0 or higher) • Upload/download database • Panel application code • Latest LCM code (V 2.16.3) addresses issue with Acclimate detectors programmed for Alarm Verification as referenced in TB07-08-01 • Corrects CPX-551 wrong component issue

  49. ONYX Series Update: NCA-2 • Current production version 11.2.4 on Magni-Fire • Allows On/Off Control of Software Zones • Local or network • Allows Zone Disable via Logic Zone • Local or network • ACS support for new DVC (V2.0) paging options • USB support (requires VeriFire Tools V5.0 or higher) • Upload/download database • Panel application code • Includes fixes for legacy panel support • Future version to support • LCD-160, LCD-80 terminal mode, CRT-2 (limited operation)

  50. ONYX Series Update: VeriFire Tools • VeriFire Tools Version 5.0 • Supports ALL ONYX Series Products • USB support for NFS2-640, NFS-320, NFS2-3030 and NCA-2 • Supports DVC • Programs and configures the DVC and associated audio amplifiers • Includes digital audio files library • Program NFS2-640 and NFS-320 ACS points for disable/enable • NFS2-640 and NFS-320 version 10.8.3 (or higher) • Available on magni-fire.com • Digital audio files posted also