1 / 5

IDTB07 report https://conferences.fnal/idtb07/

IDTB07 report https://conferences.fnal.gov/idtb07/. 2007/01/23, GLDCAL meeting K. Kawagoe (Kobe U). (Extruded Mega-strip under development). Signal from scintillator strips (@Shinshu-U). b -ray source ( 90 Sr). Strip size : 1 cm x 4.5 cm x 3 mm covered with reflector film. collimator.

Télécharger la présentation

IDTB07 report https://conferences.fnal/idtb07/

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IDTB07 reporthttps://conferences.fnal.gov/idtb07/ 2007/01/23, GLDCAL meeting K. Kawagoe (Kobe U)

  2. (Extruded Mega-strip under development)

  3. Signal from scintillator strips (@Shinshu-U) b-ray source (90Sr) Strip size : 1 cm x 4.5 cm x 3 mm covered with reflector film collimator Bias voltage : V0 + 2.1 V Temperature : 25 oC Trigger Direct readout WLSF readout Light yield ~ 21 p.e. Light yield ~ 13 p.e. Question: 94.5/347.9=0.27, 55.63/253.4=0.21. If this is true, direct readout is better in uniformity ??

  4. Comments on Fermilab TB facility • Our experience of MTBF in 1999 • No Cherenkov counters. Only SRD (synchrotron radiation detector) could be used for electron ID. • We had to bring our own drift chambers to measure the incident position. • Suffered from electric noise in the PMT signals, whose origin could not be identified. • Suffered from multi-particle events due materials in the beam. • Now we have • Gas Cherenkov counters and beamline TOF for particle ID • Tracking with MWPCs, a pixel station, and SciFi detectors. • Less material in the beam. Great improvements. Thanks a lot !! • For stable MPPC operation • Hope stable temperature at the experimental hall: MPPC is sensitive to temperature • Hope to have less electric noise than our 1999 TB.

  5. Support for DESY TB from CALICE • LED driver, monitoring system (CAN) • Ivo Polak (Prague) • DAQ, online monitoring • Georgios MAVROMANOLAKIS (Cambridge University/FNAL) • Data analysis, GRID • Roman Poeschl (LAL)

More Related