Realistic Model of the Solenoid Magnetic Field. Objectives Closed-loop model Field calculation corrections Helical model Realistic model Conclusions + further work. Paul S Miyagawa, Steve Snow University of Manchester. Objectives.

csabrina
Télécharger la présentation

Realistic Model of the Solenoid Magnetic Field

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Realistic Model of the Solenoid Magnetic Field • Objectives • Closed-loop model • Field calculation corrections • Helical model • Realistic model • Conclusions + further work Paul S Miyagawa, Steve Snow University of Manchester

  2. Objectives • Simulations of the performance of the solenoid field mapping machine have been based on a simple model of the B-field. • Want to test the performance with a more realistic model. • Realistic model seeks to improve on several aspects: • Calculating the field from a curved current path • Modelling the actual current path • Modelling the shape of the solenoid Solenoid Field Mapping Meeting

  3. Closed-Loop Model • Previously, the solenoid was modelled as a series of closed circular loops of infinitely thin wires evenly spaced in z. • For calculating the field, each loop approximated as 800 straight-line segments, and Biot-Savart law applied to each segment. • Added in field due to magnetised iron (4% of total field). • Model is symmetric in  and even in z. Solenoid Field Mapping Meeting

  4. Field Calculation Corrections • We approximate the true current path, which is helical, with straight-line segments whose end points lie on the true path. • This leads to two types of error: Inscribed polygon error • If a circle is replaced by an inscribed polygon, the average radius of the polygon is less than the radius of the circle. • This effect can be corrected by increasing the radius by 2/3 of S where S is the sagitta between the arc and the chord. Line segment integration error • The natural approximation is to use the midpoint of the segment to calculate r between the segment and the measurement point. • This leads to an error because r is different for each point on the line. This error is more significant than the inscribed polygon error. • A correction factor can be added to the magnitude of the field: Solenoid Field Mapping Meeting

  5. Field Calculation Corrections z = 0, r = 0 z = 1, r = 0 z = 0, r = 0.8 z = 1, r = 0.8 Solenoid Field Mapping Meeting 100 steps most likely sufficient, but we use 200 to be safe.

  6. Helical Model • First step towards a realistic model is to replace the series of closed loops with a helical coil. • The current starts at (0,R,hz), winds in anti-clockwise direction, and terminates at (0,R,-hz). Note that this does not form a closed path. • The overall dimensions of the coil are the same as for the closed-loop model. • Model is neither symmetric in  nor even in z. • Main differences with closed-loop model are at the ends of the coil due to difficulty in lining up the ends. Solenoid Field Mapping Meeting

  7. Realistic Model • The ATLAS solenoid consists primarily of four main coil sections. • The last loop from each section is welded to the first loop of the next section to form a single coil. • At end A, an extra cable is welded to the last loop, and the two cables are routed up through the services chimney. • At end C, an extra cable is welded to the last loop. The two cables form the return coil, which is routed along the cryostat surface to end A and up into the chimney. • Cables in the chimney are magnetically shielded. • The realistic model models the current through these main components. Solenoid Field Mapping Meeting

  8. Return Coil • The return coil consists of the two cables from the end C weld running flat along the cryostat surface. The extra cable rests on top of the main cable. • The cables are electrically isolated, so they carry the current in ratio 80:20. • In the realistic model, the cables connect to the cables from the end A weld so as to form a closed current path for the entire solenoid. Solenoid Field Mapping Meeting

  9. The dimensions given are for a warm coil in quiescent conditions. The real coil will be deformed: Shrinkage due to cool down. This is modelled as an overall scale reduction of 0.41%. Bending due to field excitation. This is modelled as the radius r being a parabolic function of z. At the centre, Δr = 0.90 mm; at the coil ends, Δr = 0.38 mm, Δz = 1.09 mm. Shape Deformations Solenoid Field Mapping Meeting

  10. Field from Realistic Model Solenoid Field Mapping Meeting

  11. Conclusions • Developed realistic model of the solenoid B-field which makes several improvements over the simple closed-loop model. • Corrections made for errors which arise from approximating curved current paths with straight-line segments: • inscribed polygon error • line segment integration error • Modelled the actual current path: • four main coil sections • welds between main sections • welds at end of solenoid • return current coil • Modelled real shape of solenoid: • shrinkage due to cool down • bending due to field excitation • Made comparisons with previous model: • Most adjustments to Bz and Br components are O(10 gauss). • Greatest adjustments are at boundaries (coil ends, weld regions). • Return coil has greatest effect on Bφ component. Solenoid Field Mapping Meeting

  12. Further Work • Investigate further refinements of realistic model: • Current flow through cable cross-section (2×6 array of wires). • Simulate performance of field mapping machine and fitting routines using B-field from realistic model. Solenoid Field Mapping Meeting