Hard Xray Diagnostic for Lower Hybrid Current Drive on Alcator C-Mod

Hard Xray Diagnostic for Lower Hybrid Current Drive on Alcator C-Mod. John Liptac. Advisor: Prof. R. Parker Readers: Prof. I. Hutchinson and Dr. P. Bonoli. NED Joint Seminar December 10, 2003. Motivation.

damita
Télécharger la présentation

Hard Xray Diagnostic for Lower Hybrid Current Drive on Alcator C-Mod

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Hard Xray Diagnostic for Lower Hybrid Current Drive on Alcator C-Mod John Liptac Advisor: Prof. R. Parker Readers: Prof. I. Hutchinson and Dr. P. Bonoli NED Joint Seminar December 10, 2003

  2. Motivation • Tokamaks are pulsed devices limited by the plasma current; however, steady state operation is very desirable for any reactor Current drive is needed • Current profile can be controlled using lower hybrid waves • Location of current is critical to performance and can be measured through Bremsstrahlung emission

  3. LH Waves • LH frequency→ x-mode (kB) root of cold plasma dispersion relation, 2lh= 2ce/(1+ 2pe/ 2ce) • LH limit:2ce » 2 » 2ci • Numbers for 5T, 1020 m-3: fce=140, fpe=90, fpi=1.4, flh=1.2, fci= 0.04 GHz • Pure LH wave is cutoff Plot conditions: Parabolic density profile with peak of 3 1020 m-3, B  1/R with B0 of 5.3 T

  4. LH Waves LHCD is calculated based on • Ray tracing • Damping calculation • k|| =(krBr+m/rB+n/RB)/|B| Experimental verification of LHCD location is needed LHCD works through electron Landau damping around v~3vth v /k • Creation of non-thermal Bremsstrahlung radiation from high energy tail Bonoli ACCOME Simulation

  5. Non-Thermal Bremsstrahlung Bremsstrahlung radiation is continuous: an electron of energy E can radiate any h < E Eelectron = 200 keV • No direct measure of distribution function, need model • e-i Bremsstrahlung is much larger than e-e for E < 500 keV • Radiation is anisotropic, peaked in the forward direction

  6. Experimental Layout C-Mod top view LH Antenna Wave Guides Klystrons HXR Diagnostic • Located on mezzanine • 12 klystrons at 250kW each →3MW • f = 4.6GHz • Located on C-port • Grill composed of 96 waveguides, 4 rows of 24 • Dynamic phase change possible, ~ms, allowing for pre-program spectra or feedback control • Located on B-port • 32 channel pinhole camera • 20-250keV energy range • ~1.5cm spatial resolution • ~10ms temporal resolution

  7. HXR Camera Design 32 channel pinhole camera using CZT detectors and fast digitization techniques C-Mod cross section with HXR camera

  8. HXR Camera Design (cont.) CdZnTe detectors: • High Z 49.1, high density 5.8g/cm3 • No cooling or magnetic shielding • Made in the USA- eV Products Fast digitization allows: • Flexibility through software data analysis • Energy resolution limited by detector • Improved noise rejection/pile up detection • Lower system cost • Possibility of real time feedback control of n|| Data management: • Up to 2GB/shot raw data • ~150 shot scratch disk • Local data processing • Processed data archived

  9. Pulse Processing Photons Detector Amplifier and Shaper Fast Digitizer Preamplifier eV Products 552mm CZT eV Products eV-5093 Preamp Gaussian Shaper DTACQ ACQ216 • Energy resolution better than 10% at 60kev • Charge transport limits count rates to ~1MHz • High sensitivity ~120mV/MeV • f =1ms • Small size 2.61.5cm • Developed in house • ~1s pulse width • DC offset • Line driver • Small size 2.57.6cm • CPCI form factor • 16ch/board at 10MHz • 1GB/board memory • 14 bit resolution

  10. Shaping Electronics Gaussian pulse shape: • No undershoot → better energy performance at high count rate • Easy to fit → reduces pile up and improves rejection Gaussian shaper realized through Sallen-Key filter and surface mount PCB • Flexible gain and pulse width • DC offset used to adjust signal into digitizer range of ± 2.5V • 50 line driver Shaper step response from PSPICE model

  11. Shielding Measured background Expected signal Neutron Rate 7.5e13 (1/s) Background measurements indicate gamma shielding is required Background measurement using pixilated detector and ASIC shot 1030605017 from t = 0.975-0.985

  12. Gamma Production in Shield MCNP using neutron background used to estimate gamma production from shield materials Estimation valid for relative contributions only from simple source model- absolute levels need correct source spatial distribution

  13. Summary • Lower hybrid waves are a tool used to study steady state operation through current profile control • A 32 channel CZT detector pinhole camera using fast digitization has been developed to measure the 20-250keV electron population resulting from LHCD • Emissivity profile reconstruction gives the LHCD location • Compact design for spatial constraints • Camera will be ready for operation when LH is installed