1 / 18

Measurement of R with KLOE-2

Measurement of R with KLOE-2. G.V. & F.N. 13/1/2010. Error budget on a  HLO .  a  HLO = 5.3=3.3(  s<1GeV)  3.9 (1<  s<2GeV))  1.2(  s>2GeV). ~75% (mostly 2  ). ~40%. ~55%. error 2. contributions. Very important also the region 1-2 GeV !!!. But . in the range < 1 GeV

dareh
Télécharger la présentation

Measurement of R with KLOE-2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Measurement of R with KLOE-2 G.V. & F.N. 13/1/2010

  2. Error budget on aHLO aHLO=5.3=3.3(s<1GeV) 3.9(1< s<2GeV)) 1.2(s>2GeV) ~75% (mostly 2) ~40% ~55% error2 contributions Very important also the region 1-2 GeV !!! But in the range < 1 GeV contributes to 70% !

  3. A rough estimate for g-2 aexp- atheo,SM= (27.7 8.4)10-10 (3.3) [Eidelman, TAU08] 8.4= ~5HLO~3LbL6BNL 4 3 3 1.6NEW G-2 7-8if 27.7 will remain the same) FJ08 aHLO=5.3=3.3(s<1GeV) 3.9(1< s<2GeV) 1.2(s>2GeV) aHLO3=2.5 (s<1GeV)  1.5 (s<1GeV) 1.2(s>2GeV This means: HAD ~ 0.4% s<1GeV (instead of 0.7% as now) HAD ~ 2% 1<s<2GeV (instead of 6% as now) Precise measurement of HAD at low energies very important also for em !!!

  4. Comparison of error profiles for aem(MZ) and am Direct integration of energy points for aem(MZ) R at 1% in the region s < 10 GeV  improvement of ~3 in a(MZ) Use of Adler function (It allows to use pQCD in a safer way down to 2.5 GeV) for aem(MZ) 1% in the region 1<s < 2.5 GeV (which is known with 6% accuracy)  improvement of ~5 on a(MZ) as evaluated “today” by direct integration region 2m<s < 2 Direct integration of energy points for am • Extremely important region since its accounts for: • 80% of the total error on Da(5)had (using Adler function) • 95% of the tot error on am

  5. e+e- data: current and future/activities KEDR(3-5%, ~15%) KLOE-2(?) HAD ~3-5% ~7-15% ~6% ~1%

  6. Impact of KLOE-2 on inclusive measurement 20 pb-1 • Most recent inclusive measurements: MEA and B antiB, with total integrated luminosity of 200 nb-1 (one hour of data taking at 1032 cm-2 sec-1).10% stat.+ 15% syst. Errors • 2) With 20 pb-1 per energy point (1year of data taking at 1032 cm-2 sec-1 ) a precise comparison exclusive vs. inclusive can be carried out Lint (nb-1) • MEA, 14 points, Lett. Nuovo Cim.30 (1981) 65 • B antiB, 19 points, Phys.Lett.B91 (1980) 155 s (GeV) s (GeV)

  7. Can KLOE-2 measure R with 1% error in the region 1-2 GeV? • Not easy task  • Statistics OK @ 1032cm-2 sec-1 (scan) • Systematics most likely under control, given the excellent performances of KLOE+inner tracker • Precise determination of beam energy would help (using BS Compton) • Exclusive vs inclusive?

  8. Impact of DAFNE-2 on the range [1-2] GeV (2p) BaBar, with the published Lint per point BaBar, with 10  (the present Lint ) DAFNE-2, with 20 pb-1 per point • comparison among the present BaBar analysis, an (O(1 ab-1)) BaBar update, • and Lint = 20 pb-1 per energy point • @ DAFNE-2, in the impact on d(Dahad) /Dahad: • 2p+2p- : O(2%) |O(0.7%)|O(0.5%) Stat error Babar systematic error: 5% on 2 (8-14% for 2 statistical dshad / shad (%) s (GeV)

  9. Impact of DAFNE-2 on the range [1-2] GeV (2K2p) comparison among the present BaBar analysis, an (O(1 ab-1)) BaBar update, and Lint = 20 pb-1 per energy point @ DAFNE-2, in the impact on d(Dahad) /Dahad : p- p+K- K+: O(15%) |O(5%)|O(3%) BaBar, with the published Lint per point BaBar, with 10  (the present Lint ) DAFNE-2, with 20 pb-1 per point statistical dshad / shad (%) Stat error Babar systematic error: 10% s (GeV)

  10. Impact of DAFNE-2 on the range [1-2] GeV (3p) BaBar, with the published Lint per point BaBar, with 10  (the present Lint ) DAFNE2, with 20 pb-1 per point comparison among the present BaBar analysis, an (O(1 ab-1)) BaBar update, and Lint = 20 pb-1 per energy point @ DAFNE-2, in the impact on d(Dahad) /Dahad : p- p+ p0: O(9%) |O(3%)|O(1%) statistical dshad / shad (%) Stat error Babar systematic error: 6-8% s (GeV)

  11. Radiative Return @ 2.4 GeV ISR differential luminosity q0is the minimum polar angle of ISR photon. In the following, we will assume to tag the photon, withq0=20o. eis the overall efficiency m is the invariant mass of the hadronic system (p+p-, p+p- p0, 2 p0p+p-, 2 p+2p-, …) • x is 2Eg/s, s= e+e- c.m. energy • L0 is the total integrated luminosity

  12. ISR Luminosity for different c.m. energies(20o<160o) We integrated dL/dm for 25 MeV bin sizes. [pb-1/25MeV] GeV With 2 fb-1 statistical error compatibile with present Babar data (the same we can expect for the systematic error) Not competitive with the Energy scan

  13. Impact of DAFNE-2 on the range [1-2] GeV (3p) using ISR @ 2.4 GeV BaBar, with the published Lint per point BaBar, with 10  (the present Lint ) DAFNE-2, with 2 fb-1 @ 2.4 GeV comparison among the present BaBar analysis, an (O(1 ab-1)) BaBar update, and Lint = 2 fb-1 at 2.4 GeVper energy point @ DAFNE-2, in the impact on d(Dahad) /Dahad : p- p+ p0: O(9%) |O(3%)|O(8%) statistical dshad / shad (%) On the other channels the improvement can be larger s (GeV)

  14. ISR Luminosity for different c.m. energies (20o<160o vs <15o(>165o)) We integrated dL/dm for 25 MeV bin sizes. <15o(>165o) 20o<160o [pb-1/25MeV] With 10 fb-1 and <15o(>165o) statistical error almost compatibile with 1 ab-1 Babar data. However very difficult to keep systematic error at 1% without detecting photon (closing the kinematics)

  15. Different event topology btw 2.4 and 10.6 GeV: 2p+2p-channel s=2.4 GeV Eg min(qg,p) s=10.6 GeV BABAR • At 10.6 GeV: • Hard photon: Eg* = 3-5.3 GeV at s’ = 0-7 GeV. Þ No fakes from beam-gas processes. • Hadronic system collimated by recoil. • Harder spectrumÞ better detection efficiency. GeV degrees Ep • At 2.4 GeV: • Hard photon: Eg* < 1.1 GeV. • Distribution of particles and photon “uniform” distributed GeV degrees

  16. Conclusions • KLOE-2 gives an unique possibility to perform a test of SM via g-2 of muon and em. A measurement of 0.4% below 1 GeV and ~1-2% in the region 1-2.5 GeV is extremely important and would allow -by itself- to reduce the current error on aHLOof a factor 2! (bringing the 2-3 sigma to ~5-6) • ISR at 2.4 GeV can be useful for other physics item (i.e. , searches BSM, spectroscopy, etc…) • The energy scan (ES) has been compared to ISR at 2.4 GeV. ES is statistically better than ISR, and if possible must be done. 10fb-1 at 2.4 GeV can be competitive with Babar at 1ab-1, especially with photon at SA. However the systematics must be studied!

  17. spares

  18. ISR @ 2.4 GeV vs scan • Assuming to tag the ISR g, 2fb-1@ 2.4 GeV, translates in a luminosity for single point in the range [100 nb-1 - few pb-1] which would correspond to [few hours - a day] of data taking with a scan @1032 cm-2 sec-1 . • 2fb-1 @ 2.4 GeV is statistically competitive with current results from B factories (90 fb-1). The much higher ISR probability of photon emission at lower s, compensates for the lower luminosity. However we should keep in mind that the planned luminosity of B factories is 1000 fb-1. • In any case different systematics, background, etc… ISR @ 2.4 GeV vs B-factories

More Related