An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introduction to Cortical Auditory Evoked Potentials (CAEP) Manufactured by Frye Electronics Many thanks to the researchers at NAL who put together much of the information of this presentation.

  2. From Sydney to Portland

  3. Clinical Uses of HEARLab ACA • Verifying the effectiveness of hearing aid fittings on infants and adults or older children with disabilities in addition to hearing loss • Estimating audiometric thresholds in adults who may not cooperate in conventional hearing test (worker’s compensation) • Testing infants and children with auditory neuropathy

  4. First: How does HEARLab work? Sound stimulus  Generates neural activity  Measured by electrodes  Analyzed by HEARLab

  5. What is an Auditory Evoked Potential? • The human brain generates random electrical activity continually • We can record this electrical activity using electrodes on the scalp (EEG) • Sound stimulates neural activity in the brain that we can extract from the total EEG • The electrical activity generated from exposure to sound is called an Auditory Evoked Potential (AEP)

  6. Auditory Evoked Potentials Auditory Brainstem Response (ABR) Cortical Auditory Evoked Potential (CAEP) From: Katz, J (Ed.) Handbook of Clinical Audiology 4th Ed (Chpt 22)

  7. Cortical Response Auditory Brainstem Response Baer, 2003

  8. Electrode Placement From: Hall, J.W. (1992) Handbook of Auditory Evoked Potentials

  9. Obligatory CAEPs: Adult responses from several sites From:Vaughan, H.G., Ritter, W. (1970) The sources of auditory evoked responses recorded from the human scalp. Electroencephalography and Clinical Neurophysiology. Vol 28.

  10. Test Stimuli • ABR • Broadband clicks (1 ms) • Frequency-specific pips (1 ms) • HEARLab CAEP • Speech stimuli - /m/ /g/ /t/ (30 ms) • Highly frequency-specific tone bursts (30 ms)

  11. ABR vs Audiometer Stimuli ABR click Audiometer tone ABR pip From: Abramovich (1990) ERA in Clinical Practice.

  12. ABRs Unsuitable for Aided Testing • ABR test occurs 1-5 ms after stimulus • Digital hearing aids have digital processing delay (2-15 ms) • Hearing aids respond poorly to ABR clicks

  13. CAEP Better Solution for Aided Testing • Test occurs 50-300 ms after stimulus • Stimulus uses speech stimulus (30 ms) • Frequency emphasis speech sounds • /m/ - Low frequency emphasis • /g/ - Mid frequency emphasis • /t/ - High frequency emphasis

  14. HEARLab “Speech” Stimuli Unlike ABR, latency of the CAEP test (50-200 ms) allows the use of longer test stimuli better suited for use with hearing aids

  15. Auditory Neuropathy • Outer hair cells within the cochlea are functional, but sound information is not transmitted to the auditory nerve and brain properly. • Diagnosis: • Positive Otoacoustic Emissions (OAE) • Negative ABR • Some Auditory Neuropathy patients have relatively normal hearing levels. Others may have severe hearing losses • CAEP can be used to assess audibility of highly-frequency specific tones.

  16. Subj: normal hearing adult Stim: /g/ No. of responses: 100 (and replicated) 30 dB SL 20 dB SL 10 dB SL µV 2.5 -100 0 100 200 300 400 500 600 ms

  17. Infant CAEPs with Maturity From: Steinschneider, M., et al., (1992) Event–related potentials in developmental Neuropsychology. In Handbook of Neuropsychology Vol 6 Elsevier Science

  18. HEARLab Example of CAEP Infant Response Adult Response

  19. Traditional Problems with CAEP • Unlike ABR, CAEP waveforms vary from individual to individual • Requires experience interpreting CAEP traces for clients of different ages to decide whether the sounds are likely audible to the patient

  20. Solution! • Statistical Analysis using Multivariate Analysis of Variance (MANOVA) with Hotellings T2 As the HEARLab test runs, an ongoing statistical analysis of the results are performed. If the results are < 0.05, there is a high probability a response is present.

  21. NAL Research shows Hotellings T2 works! • Study done comparing a group of experts on CAEP to the Hotellings analysis • Results shows that Hotellings is at least equal to, if not more able, than the “composite” examiner to differentiate a CAEP from random noise at sensation levels of 10 dB or more

  22. Example of HEARLab Test Test Controls Most recent epoch Average Statistics Residual Noise

  23. Clinical Use of HEARLab ACA • Aided testing with speech sounds (infants, mentally disabled) • Frequency-specific threshold estimation (multiply disabled, worker’s compensation, auditory neuropathy) • Customer base: • Hospitals • Nursing homes • Hearing aid clinics

  24. Early Hearing Intervention programs Screening ABR/OAE  Diagnostic ABR  RECD/Simulated Real-ear  NEW!!! HEARLab ACA

  25. Next: Demonstration of HEARLab ACA software!