An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Date Customer Mode Dept. Complaint Fact Corrective Action Date Cate. 1/4 QMSC/Apple ADA007-290H BU1 1/10 M QMSC ADA007-290H BT#301Issue -- Jan • QSMC發現睡眠狀態單體無法開機*7台(D209~D212) • 檢查廠內製程測試條件,發現2012.10.6~2012.10.19有修改過FUN2測試程式,增加50mA ( SPEC規格 5 mA)導致不良單體無法測試出來. • NXP VF值偏大,導致單體不良,而FUN2測試程式有修改,所以無法測試出來 1. 廠內修改測試程式 2. 系統禁用 NXP 材料

  2. Date Customer Mode Dept. Complaint Fact Corrective Action Date Cate. 12/28 HP APB002-020H2 BU1 1/14 P HP APB002-020H2 AB膠 Issue -- Jan • 客戶端發現單體有油污 * 5pcs • 此儀器在 (2012.11.5~15)之間有被摔過,但是產線並沒有告知廠內維修人員僅對鬆動的膠管進行更換, 2012.12.26 經儀器廠商進廠維修確認,發現儀器的計量泵有偏移. • 分析為儀器計量泵損傷,導致AB膠的出膠比例失調,導致AB膠無法乾 • 1/18 廠商已經調用新儀器,經QE和IE上線確認,新儀器出膠比例正常,出膠量相同,舊儀器已經被廠商調回. • 修改 MOI 重新定義鑒定方式,將原來的烘烤,修改為點檢出膠量,點檢頻率:開線前做膠乾測試。 • 使用前需將管內膠清空,確保混合的都是新膠。 • 評估新的替代用膠,需達到相同的散熱效果且易管控,不需做混拌膠的動作