1 / 16

Microcogenera zione evoluta

Microcogenera zione evoluta. L‘unità di micro-cogenerazione Dachs. Referente: Mauro Grecchi. Utilizzo efficiente dell’EP. Elettricit à : 27 %. Combustibile: 100% PCI. con condensazione fumi η 1 ° > 100% !!. Calore: 73 %. Calore: 61 %. 500 kg di meccanica robusta ed affidabile.

derry
Télécharger la présentation

Microcogenera zione evoluta

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Microcogenerazione evoluta L‘unità di micro-cogenerazione Dachs Referente: Mauro Grecchi Tecnology Focus COGENA – SenerTec GmbH

  2. Utilizzo efficiente dell’EP Elettricità: 27% Combustibile: 100% PCI con condensazione fumi η1° > 100% !! Calore: 73% Calore: 61% Tecnology Focus COGENA – SenerTec GmbH

  3. 500 kg di meccanica robusta ed affidabile Propulsore appositamente sviluppato per l’applicazione. Lavorazioni precise e massima qualità negli assemblaggi. Tecnology Focus COGENA – SenerTec GmbH

  4. Il dimensionamento base load Pt [kW] 100 kW Caldaia Pot. max istantanea Pot. min. Pot. media 00:00 24:00 12,5 kW Riscaldamento Cogeneratore Produzione acqua calda sanitaria Gennaio Dicembre Tecnology Focus COGENA – SenerTec GmbH

  5. Modularità e scalabilità Saving in €/anno + + + 2.000-3.000 h/a 3.000-5.000 h/a 4.000-8.000 h/a >6.000 h/a >8.000 h/a kWt 35 50 100 250 Residenziale di lusso Piccoli condomini Condominimedi e grandi Hotel, Pensioni Grandi edifici Piscine, cliniche Case di riposo Tecnology Focus COGENA – SenerTec GmbH

  6. Vantaggi della soluzione in cascata SICUREZZA grazie alla ridondanza RENDIMENTO COSTANTE accensionein sequenza in funzione del carico a rendimento elettrico costante SCALABILITA’ possibilità di realizzare l’impianto in più step, per adeguarlo ai reali fabbisogni energetici dell’edificio DURATA & AFFIDABILITA’ aspettativa vita motore: 80mila ore20mila unità prodotte dal 1996 ad oggi ηel Pel Tecnology Focus COGENA – SenerTec GmbH

  7. Salumificio a Sermide (MN) Dati utenza: Costo combustibile: 0,40 €/m3 Consumo combust.: 16.000 m3/a Rendim. caldaia: 78 % Costo elettricità: 0,14 €/kWh Consumo elettrico: 99.690 kWh/a Dati tecnici Dachs G5.5: Potenza elettrica: 5,5 kW Potenza termica: 12,5 kW Potenza entrante: 20,5 kW Ricavi generati: Energia elettrica: 6.900 h/a x 5,5 kW x 0,14 €/kWh = 5.313 €/a Energia termica: 6.900 h/a x 12,5 kW x 0,052 €/kWh = 4.485 €/a Totale ricavi = 9.798 €/a Costi di esercizio: Combustibile: 6.900 h/a x 2,06 m3/h x 0,40 €/h = 5.686 €/a Manutenzione: 6.900 h/a x 5,5 kW x 0,02 €/kWh = 759 €/a Totale costi esercizio = 6.445 €/a Risparmio annuo sui costi energetici: 3.353 €/a Risparmio in 10 anni con incremento medio 4%: 40.263 €/a Configurazione impianto: no. unità Dachs = 1 funzionamento = 6.900 h/a L’energia termica prodotta è impiegata per produzione di acqua calda sanitaria e per le batterie di post-riscaldo delle celle di stagionatura Tecnology Focus COGENA – SenerTec GmbH

  8. Villa con piscina a Pavullo (RE) Dati utenza: Costo combustibile: 0,65 €/m3 Consumo combust.: 16.000 m3/a Rendim. caldaia: 78 % Costo elettricità: 0,14 €/kWh Consumo elettrico: 99.690 kWh/a Dati tecnici Dachs G5.5 cond.: Potenza elettrica: 5,5 kW Potenza termica: 14,7 kW Potenza entrante: 20,5 kW Ricavi generati: Energia elettrica: 5.000 h/a x 5,5 kW x 0,19 €/kWh = 5.225 €/a Energia termica: 5.000 h/a x 14,7 kW x 0,084 €/kWh = 6.174 €/a Totale ricavi = 11.399 €/a Costi di esercizio: Combustibile: 5.000 h/a x 2,06 m3/h x 0,65 €/h = 6.695 €/a Manutenzione: 5.000 h/a x 5,5 kW x 0,02 €/kWh = 550 €/a Totale costi esercizio = 7.245 €/a Risparmio annuo sui costi energetici: 4.154 €/a Risparmio in 10 anni con incremento medio 4%: 49.879 €/a Configurazione impianto: no. unità Dachs = 1 funzionamento = 5.000 h/a L’energia termica prodotta è impiegata per riscaldamento ambienti e piscina con copertura scorrevole e per produzione di acqua calda sanitaria. Tecnology Focus COGENA – SenerTec GmbH

  9. Supermercato a Scandiano (RE) Dati utenza: Costo combustibile: 0,39 €/m3 Consumo combust.: 16.000 m3/a Rendim. caldaia: 90 % Costo elettricità: 0,135 €/kWh Consumo elettrico: 200.000 kWh/a C.O.P. Chiller: 2,3 Dati tecnici Dachs G5.5: Potenza elettrica: 5,5 kW Potenza termica: 12,5 kW Potenza entrante: 20,5 kW Ricavi generati: Energia elettrica: 6.600 h/a x 16,5 kW x 0,135 €/kWh = 14.702 €/a Energia termica: 4.800 h/a x 37,5 kW x 0,044 €/kWh = 7.920 €/a Energia freddo: 1.800 h/a x 35,6 kW x 0,059 €/kWh = 3.780 €/a Totale ricavi = 26.402 €/a Costi di esercizio: Combustibile: 6.600 h/a x 6,18 m3/h x 0,40 €/h = 15.907 €/a Manutenzione: 6.600 h/a x 16,5 kW x 0,018 €/kWh = 1.690 €/a Totale costi esercizio = 17.868 €/a Risparmio annuo sui costi energetici: 8.534 €/a Risparmio in 10 anni con incremento medio 4%: 102.460 €/a Configurazione impianto: no. unità Dachs = 3 funz. riscald/ACS = 4.800 h/a funz. raffrescam. = 1.800 h/a C.O.P. ass. Br-Li = 0,95 Impianto trigenerativo per climatizzazione invernale ed estiva degli ambienti interni Tecnology Focus COGENA – SenerTec GmbH

  10. Wellness a Viareggio (LU) Dati utenza - 1: Consumo combust.: 83.335 m3/a Allacciamento el. BT: 400 kW Costo elettricità: 0,139 €/kWh Consumo elettrico: 362.000 kWh/a Analisi storico fabbisogno termico: JAN 103.066 kWh/mese FEB 118.891 kWh/mese MRZ 103.187 kWh/mese APR 64.124 kWh/mese MAI 41.637 kWh/mese JUN 38.268 kWh/mese JUL 30.971 kWh/mese AUG 39.263 kWh/mese SEP 25.384 kWh/mese OKT 42.243 kWh/mese NOV 38.849 kWh/mese DEZ 89.285 kWh/mese TOT 735.169 kWh/anno 70 kWel & 147,5 kWt 16,5 kWel & 44,1 kWt Tecnology Focus COGENA – SenerTec GmbH

  11. STB STB STB Schema idraulico di massima T DN40 Q = 0÷6 m3/h VARIABILE IN FUNZIONE DELTA (T1 - T2) DN50 DN50 Serbatoio di accumulo inerziale V = 2,5 m3 Coibentazione PUR 100 mm Rapportoaltezza / diametro≥ 2,5 Serbatoio di accumulo inerziale V = 2,5 m3 Coibentazione PUR 100 mmRapportoaltezza / diametro≥ 2,5 T1 Caldaia 350 kW Caldaia 350 kW DN40 T2 DN50 Tecnology Focus COGENA – SenerTec GmbH

  12. Business Plan con 3 Dachs condensing Dati utenza - 2: Costo combustibile: 0,61 €/m3 Fabbisogno term.: 735.169 kWh/a Rendim. caldaia: 79 % Costo elettricità: 0,139 €/kWh Consumo elettrico: 362.000 kWh/a Dati tecnici Dachs G5.5 cond.: Potenza elettrica: 5,5 kW Potenza termica: 14,7 kW Potenza entrante: 20,5 kW Ricavi generati: Energia elettrica: 7.500 h/a x 16,5 kW x 0,139 €/kWh = 17.201 €/a Energia termica: 7.500 h/a x 44,1 kW x 0,077 €/kWh = 25.468 €/a Totale ricavi = 42.669 €/a Costi di esercizio: Comb acc ridott: 7.500 h/a x 4,13 m3/h x 0,431 €/h = 13.350 €/a Comb acc piena: 7.500 h/a x 2,06 m3/h x 0,61 €/h = 9.425 €/a Manutenzione: 7.500 h/a x 16,5 kW x 0,018 €/kWh = 2.228 €/a Totale costi esercizio = 25.002 €/a Risparmio annuo sui costi energetici: 17.667 €/a Risparmio in 10 anni con incremento medio 4%: 212.500 €/a Configurazione impianto: no. unità Dachs = 3 funzionamento = 7.500 h/a L’energia termica prodotta è impiegata per riscaldamento ambienti, vasche e per produ-zione di acqua calda sanitaria. Contatore fiscale di produzione Tecnology Focus COGENA – SenerTec GmbH

  13. Business Plan con sez. da 70 kWe Ricavi generati: Energia elettrica: 70,0 kW x 0,139 €/kWh = 9,73 €/h Energia termica: 147,5 kW x 0,077 €/kWh = 10,32 €/h Totale ricavi = 20,05 €/h Costi di esercizio: Comb acc ridott: 17,5 m3/h x 0,431 m3/h = 7,54 €/h Comb acc piena: 8,6 m3/h x 0,61 m3/h = 5,35 €/h Manutenzione: 70 kW x 0,030 €/kWh = 2,10 €/h Totale costi esercizio = 14,89 €/h Risparmio orario sui costi energetici: 5,16 €/h Dati utenza - 2: Costo combustibile: 0,61 €/m3 Fabbisogno term.: 735,17 kWh/a Rendim. caldaia: 79 % Costo elettricità: 0,139 €/kWh Consumo elettrico: 362.000 kWh/a Dati tecnici sezione da 70 kW.: Potenza elettrica: 70,0 kW Potenza termica: 147,5 kW Potenza entrante: 250,6 kW Assunzione arbitraria tempi funzionam. = 4.500 h/a Risparmio annuo sui costi energetici: = 23.220 €/a ATTENZIONE: 1) tutta l’elettricità prodotta deve essere autoconsumata !! 2) tutto il calore prodotto deve essere calore utile !! Tecnology Focus COGENA – SenerTec GmbH

  14. Business Plan con sez. da 70 kWe Analisi storico fabbisogno termico: MAI 41.637 kWh/mese JUN 38.268 kWh/mese JUL 30.971 kWh/mese AUG 39.263 kWh/mese SEP 25.384 kWh/mese OKT 42.243 kWh/mese NOV 38.849 kWh/mese Ricavi generati: Energia elettrica: 70,0 kW x 0,139 €/kWh = 9,73 €/h Energia termica: 54,8 kW x 0,077 €/kWh = 4,22 €/h Totale ricavi = 13,95 €/h Costi di esercizio: Comb acc ridott: 17,5 m3/h x 0,431 m3/h = 7,54 €/h Comb acc piena: 8,6 m3/h x 0,61 m3/h = 5,35 €/h Manutenzione: 70 kW x 0,030 €/kWh = 2,10 €/h Totale costi esercizio = 14,89 €/h Risparmio orario sui costi energetici: - 0,94 €/h In alternativa è possibile modulare,ma la modulazione si paga: 1) in termini di rendimento elettrico 2) con incremento del costo di manutenzione Tecnology Focus COGENA – SenerTec GmbH

  15. Agriturismo a Ponteginori (PI) • Configurazione impianto ad isola: • Potenza generatore: 5,5 kW • Cluster inverter: 3 x 5 kW • Pacco batterie 48 V: 800 Ah • Il sistema installato soddifa: • assorbimenti istantanei  20 kW • consumi elettrici  50 kWh/gg Ulteriori caratteristiche: Scalabilità mediante l‘aggiunta di ulteriori unità Dachs Modem GSM per telegestione e diagnositica a distanza. Gestione ottimizzata per la massima vita utile delle batterie. Dissipazione remota silenziata per funzionamento estivo Tecnology Focus COGENA – SenerTec GmbH

  16. Buoni motivi per cogenerare • tecnologia con miglior R.O.I. se l’impianto è correttamente dimensionato sul fabbisogno termico di base • massima riduzione specifica di CO2 in relazione all’investimentoogni 1.000 € investite:- FV: 120 ÷ 180 kg/anno- CHP: 480 ÷ 800 kg/anno • costanza di rendimento e produttività utilizzando unità di provata affidabilità, installate e manutenute correttamente • miglioramento classe energetica dell’edificio Tecnology Focus COGENA – SenerTec GmbH