1 / 87

Essentials of Fire Fighting, 5th Edition

Firefighter I. 17

diem
TΓ©lΓ©charger la prΓ©sentation

Essentials of Fire Fighting, 5th Edition

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Essentials of Fire Fighting, 5th Edition

    2. Firefighter I 17–1 Chapter 17 Lesson Goal After completing this lesson, the student shall be able to perform loss control operations following the policies and procedures set forth by the authority having jurisdiction (AHJ).

    3. Firefighter I 17–2 Specific Objectives 1. Explain the philosophy of loss control. 2. Discuss planning and procedures for salvage operations. 3. Describe salvage covers, salvage cover maintenance, and equipment used in salvage operations.

    4. Firefighter I 17–3 Specific Objectives 4. Summarize basic principles of salvage cover deployment. 5. Summarize methods used to catch and route water from fire fighting operations and cover openings using salvage. 6. Discuss overhaul operations.

    5. Firefighter I 17–4 Specific Objectives 7. Describe tools and equipment used in overhaul. 8. Discuss fire safety during overhaul. 9. Discuss locating hidden fires. 10. Summarize the overhaul process.

    6. Firefighter I 17–5 Specific Objectives 11. Clean, inspect, and repair a salvage cover. (Skill Sheet 17-I-1) 12. Roll a salvage cover for a one-firefighter spread. (Skill Sheet 17-I-2) 13. Spread a rolled salvage cover – One-firefighter method. (Skill Sheet 17-I-3)

    7. Firefighter I 17–6 Specific Objectives 14. Fold a salvage cover for a one-firefighter spread. (Skill Sheet 17-I-4) 15. Spread a folded salvage cover – One-firefighter method. (Skill Sheet 17-I-5) 16. Fold a salvage cover for a two-firefighter spread. (Skill Sheet 17-I-6)

    8. Firefighter I 17–7 Specific Objectives 17. Spread a folded salvage cover – Two-firefighter balloon throw. (Skill Sheet 17-I-7) 18. Construct a water chute without pike poles. (Skill Sheet 17-I-8) 19. Construct a water chute with pike poles. (Skill Sheet 17-I-9)

    9. Firefighter I 17–8 Specific Objectives 20. Construct a catchall. (Skill Sheet 17-I-10) 21. Locate and extinguish hidden fires. (Skill Sheet 17-I-11)

    10. Firefighter I 17–9 Philosophy of Loss Control Minimize damage and provide customer service through effective mitigation and recovery efforts Builds goodwill

    11. Firefighter I 17–10 Salvage and Overhaul Most effective means of loss control Restoration of the property

    12. Firefighter I 17–11 Salvage Operations that aid in reducing primary and secondary damage during fire fighting Primary damage is caused by the fire Secondary damage is caused by fire suppression activities

    13. Firefighter I 17–12 Salvage Both primary and secondary damage can be minimized through salvage Some damages cannot be avoided Starts as soon as adequate personnel are available May be done simultaneously with fire attack

    14. Firefighter I 17–13 Overhaul Consists of operations involved in searching for and extinguishing hidden or remaining fires Protecting the scene and preserving evidence are components of overhaul

    15. Firefighter I 17–14 Overhaul If possible, do not start overhaul operations until Fire is under control Fire cause has been determined Evidence has been identified and protected

    16. Firefighter I 17–15 Salvage Methods and operating procedures by which firefighters attempt to save property and reduce further damage Removing property Covering property Other means

    17. Firefighter I 17–16 Salvage Proper salvage operations Early planning Knowing the procedures Being familiar with tools and equipment

    18. Firefighter I 17–17 Planning for Salvage Operations Efficient operations require planning and training SOPs should be developed

    19. Firefighter I 17–18 Planning for Salvage Operations Preincident plans High-value contents Residential occupancies Commercial occupancies Work with loss-control representatives

    20. Firefighter I 17–19 Salvage Procedures Operations can be started at same time as fire attack Group building contents into compact piles

    21. Firefighter I 17–20 Salvage Procedures Group household furnishings in center of the room Raise furniture off wet floors

    22. Firefighter I 17–21 Salvage Procedures Commercial occupancies present special challenges

    23. Firefighter I 17–22 Salvage Procedures Large quantities of water can be removed by a variety of methods Water may ruin finishes; wipe off surfaces

    24. Firefighter I 17–23 Salvage Covers Made of waterproof canvas materials Manufactured in various sizes Have reinforced corners and edge hems

    25. Firefighter I 17–24 Salvage Covers Synthetic covers Lightweight Easy to handle Economical Indoor and outdoor use Some covers may be disposable

    26. Firefighter I 17–25 Salvage Cover Maintenance Proper cleaning, drying, and repairing increases service life

    27. Firefighter I 17–26 Salvage Cover Maintenance Canvas salvage covers Wetting or rinsing with hose stream and scrubbing with a broom Detergent solution if needed Don’t let dry when dirty Should be completely dry before being folded and placed in service

    28. Firefighter I 17–27 Salvage Cover Maintenance Synthetic salvage covers Do not require as much maintenance as canvas May be folded wet Usually better to let dry first After salvage covers are dry, examine for damage

    29. Firefighter I 17–28 Salvage Cover Maintenance Look up at the underside to locate holes Mark holes with chalk or marking pen Repair holes

    30. Firefighter I 17–29 Salvage Equipment Should be located in a readily accessible area on apparatus SOPs dictate where equipment is carried and who performs operations

    31. Firefighter I 17–30 Salvage Equipment Keep smaller tools/equipment in a salvage toolbox Plastic tub may be used for supplies

    32. Firefighter I 17–31 Typical Salvage Equipment Electrician’s pliers Sidecutters Various chisels Tin snips Tin roof cutter Adjustable wrenches Pipe wrenches

    33. Firefighter I 17–32 Typical Salvage Equipment Padlock and hasp Hinges Screwdriver(s) Battery-operated power tools Hydraulic jack Assortment of nails

    34. Firefighter I 17–33 Typical Salvage Equipment Mops Squeegees Scoop shovels Brooms Mop buckets with wringers Automatic sprinkler kit Water vacuum

    35. Firefighter I 17–34 Typical Salvage Equipment 100-foot (30 m) length of electrical cable Pigtail ground adapters Approved ground fault interruption device Salvage covers J-Hooks

    36. Firefighter I 17–35 Equipment Descriptions Automatic sprinkler kit Needed for buildings protected by automatic sprinkler systems Used to stop flow of water from an open sprinkler

    37. Firefighter I 17–36 Equipment Descriptions Carryalls — Used to carry debris, catch falling debris, and provide a water basin for immersing small burning objects

    38. Firefighter I 17–37 Equipment Descriptions Floor runners — Protect floor coverings; lightweight, tough, heat and water resistant, easy to maintain

    39. Firefighter I 17–38 Equipment Descriptions Dewatering devices Used to remove water from basements, elevator shafts, and sumps Should not use fire department pumpers Trash-type pumps are best for salvage Use a jet-siphon device or submersible pump for removal of excess water

    40. Firefighter I 17–39 Equipment Descriptions Water vacuum — Used to dewater floors, carpets, other areas where water is not deep enough to be picked up by submersible pump or siphon ejector

    41. Firefighter I 17–40 Equipment Descriptions J-hooks — Driven into walls or wooden framing to provide a strong point from which to hang things

    42. Firefighter I 17–41 Equipment Descriptions S-hooks — Used for the same purpose as J-hooks but cannot be driven into walls or framing; must have a horizontal ledge

    43. Firefighter I 17–42 One-Firefighter Spread with a Rolled Salvage Cover One person can quickly unroll a cover May be carried on the shoulder or under the arm

    44. Firefighter I 17–43 One-Firefighter Spread with a Folded Salvage Cover Two firefighters are needed to make fold May be carried in any manner

    45. Firefighter I 17–44 Two-Firefighter Spread with a Folded Salvage Cover Large salvage covers cannot be easily handled by a single firefighter Carry this fold on the shoulder with open edges next to neck

    46. Firefighter I 17–45 Two-Firefighter Spread with a Folded Salvage Cover Position cover so carrier can grab lower pair of corners and second firefighter can grab uppermost pair

    47. Firefighter I 17–46 Two-Firefighter Spread with a Folded Salvage Cover Balloon throw is most common method for deployment

    48. Firefighter I 17–47 Using Chutes: Removing Water Practical way to remove water that comes through the ceiling from upper floor May be constructed on floor below fire fighting operations

    49. Firefighter I 17–48 Using Chutes: Removing Water Prepared chutes are approximately 10 feet (3 m) long Chutes can be constructed from plastic sheeting, a heavy-duty stapler, and duct tape

    50. Firefighter I 17–49 Using Chutes: Constructing a Catchall Constructed from a salvage cover placed on the floor to hold small amounts of water

    51. Firefighter I 17–50 Using Chutes: Constructing a Catchall Temporarily control large amounts of water Place into position as soon as possible Usually requires two people

    52. Firefighter I 17–51 Splicing Covers Used when: Objects/groupings are large Long chutes or catchalls need to be made Splice covers with watertight joints

    53. Firefighter I 17–52 Splicing a Chute to a Catchall Method of removing accumulated water should be prepared Submersible pumps may be used Water chute spliced to the catchall

    54. Firefighter I 17–53 Covering Openings One of final parts of salvage operations Prevents damage by weather

    55. Firefighter I 17–54 Covering Openings Cover doors/windows Cover openings in roofs

    56. Firefighter I 17–55 Overhaul Operations conducted once main body of fire has been extinguished Searching for and extinguishing hidden or remaining fire Placing building and contents in safe condition

    57. Firefighter I 17–56 Overhaul Operations conducted once main body of fire has been extinguished Determining fire cause Recognizing and preserving evidence of arson

    58. Firefighter I 17–57 Safety During Overhaul Steps required Inspecting premises Developing operational plan Providing tools and equipment Eliminating or mitigating hazards

    59. Firefighter I 17–58 Safety During Overhaul Toxic gases Common and dangerous threat during overhaul Wear appropriate PPE, including respiratory protection

    60. Firefighter I 17–59 Safety During Overhaul Other hazards are present, such as fire-weakened floors Mark or barricade hazardous areas Use gloves and eye protection

    61. Firefighter I 17–60 Safety During Overhaul Physical conditioning and correct lifting are necessary Fatigue is preventable cause of injury

    62. Firefighter I 17–61 Overhaul Tools and Equipment Pike poles and plaster hooks Axes Prying tools Power saws, drills, and screwdrivers

    63. Firefighter I 17–62 Overhaul Tools and Equipment Carryall, buckets, and tubs Shovels, bale hooks, and pitchforks Thermal imaging camera

    64. Firefighter I 17–63 Supervision of Overhaul By a supervisor/officer not directly engaged in overhaul tasks Fire investigator should be involved

    65. Firefighter I 17–64 Fire Safety During Overhaul Size of charged hoselines in overhaul may not be the same Disconnecting fire apparatus from hydrants Departmental SOPs may dictate one supply line left in place

    66. Firefighter I 17–65 Fire Safety During Overhaul Attack lines used for overhaul are typically 1½ inch (38 mm) or 1Ύ inch (45 mm) Water fire extinguishers or booster hoses may be used for small fires One attack line should be available

    67. Firefighter I 17–66 Fire Safety During Overhaul Place nozzle so it will not cause additional damage Do not allow water damage from leaking hoselines Use a 100-foot (30 m) hoseline as the first section on attack lines

    68. Firefighter I 17–67 Overhaul Safety Considerations Maintain situational awareness Work in teams of two or more Maintain awareness of exit routes Maintain a RIC

    69. Firefighter I 17–68 Overhaul Safety Considerations Monitor personnel for rehab Beware of hidden gas or electrical utilities Continue using accountability system

    70. Firefighter I 17–69 Locating Hidden Fires Before starting a search, evaluate the condition of the area Factors that affect condition of the building Intensity of the fire Amount of water used for control

    71. Firefighter I 17–70 Indicators of Loss of Structural Integrity Weakened floors Concrete that has spalled Weakened steel roof members Walls offset Weakened roof trusses Mortar in wall joints opened

    72. Firefighter I 17–71 Indicators of Loss of Structural Integrity Wall ties holding veneer/curtain walls melted Heavy storage on mezzanines or upper floors Water pooled on upper floors Large quantities of wet insulation

    73. Firefighter I 17–72 Detecting Hidden Fires Sight Touch Sound Electronic sensors

    74. Firefighter I 17–73 Overhaul Procedures Begins in the area of most severe fire involvement Looking for fire extension should begin as soon as possible after fire is declared under control Systematically carried out

    75. Firefighter I 17–74 Overhaul Procedures If fire extended to other areas, path must be determined When floor beams are burned at ends or where they enter a party wall, flush the voids in the wall with water

    76. Firefighter I 17–75 Overhaul Procedures Check far side of the wall to see if fire or water has come through. Thoroughly check insulation materials

    77. Firefighter I 17–76 Understanding Basic Building Construction Assists firefighters in searching for hidden fires Windows or doors Fire may remain within frames or casings Open these areas to ensure complete extinguishment

    78. Firefighter I 17–77 Building Construction and Overhaul When fire has burned around combustible roof or cornice, open cornice and inspect for hidden fires Balloon construction — Check the attic and basement for fire extension

    79. Firefighter I 17–78 Building Construction and Overhaul Opening concealed spaces Move the furnishings of the room to locations where they will not be damaged Consider electrical wiring, gas piping, or plumbing Make neat, planned openings to ensure extinguishment and facilitate restoration

    80. Firefighter I 17–79 Building Construction and Overhaul Ceilings may be opened from below using a pike pole or other tool The plaster must first be broken on some ceilings When pulling a ceiling, do not stand directly under area to be opened

    81. Firefighter I 17–80 Building Construction and Overhaul Always position body between area being pulled and doorway to keep exit route from being blocked Always wear full protective clothing, including eye and respiratory protection

    82. Firefighter I 17–81 Building Construction and Overhaul Small burning objects Submerge entire objects in containers of water Bathtubs, sinks, lavatories, wash tubs Remove larger furnishings to the outside

    83. Firefighter I 17–82 Building Construction and Overhaul Scorched or partially burned articles may prove helpful to an investigator Use of wetting agents such as Class A foam is valuable Cotton, upholstery, and baled goods Must break bales of rags, cotton, hay apart

    84. Firefighter I 17–83 Summary Customer service is the core of everything that fire departments do. Loss control is an important component of fire department service delivery and is but one aspect of customer-service opportunities.

    85. Firefighter I 17–84 Summary Salvage and overhaul operations are two of the most effective means of loss control. Planning, procedures, and equipment are essential for effective loss-control operations.

    86. Firefighter I 17–85 Review Questions 1. What is the difference between salvage and overhaul? 2. List five items used in salvage operations. 3. How can water be removed from fire fighting operations using salvage covers?

    87. Firefighter I 17–86 Review Questions 4. When should overhaul start? 5. List three indicators of possible loss of structural integrity. 6. What are visual indicators of hidden fires.

    88. Firefighter I 17–87 Review Questions 7. What sounds may indicate a hidden fire? 8. Where does overhaul typically begin?