Senior Design Update: 3 / 19 /2014. Jacob Bumpus, BME/EE 2014 Casey Fitzgerald, BME 2014 Michael Schultis, BME/EE 2014. Fail Safes. Set point = 0 O verrides the PID controller Record Max/Min Pressure Alert user of potential errors Mass Balance Software Zero Monitor total mass

dillon
Télécharger la présentation

Senior Design Update: 3 / 19 /2014

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Senior Design Update: 3/19/2014 Jacob Bumpus, BME/EE 2014 Casey Fitzgerald, BME 2014 Michael Schultis, BME/EE 2014

  2. Fail Safes • Set point = 0 • Overrides the PID controller • Record Max/Min Pressure • Alert user of potential errors • Mass Balance Software Zero • Monitor total mass • Shut down pressure and flow, no flooding balance • Maximum Pressure • If exceeded, set pressure to zero Error Handling Demo gif

  3. Hardware Progress • Syringe pump • Removal of Large Power supply • Implemented much smaller, more portable solution • Updated circuitry components • Allows for greater precision for PID and feedback control • Since receiving connectors, we’ve begun container designs/layouts

  4. Pulsatility • Working on updating pump control panel to • take a series of flow rates and time intervals • File input or manual input • Convert flow  RPM automatically based on tubing selection

  5. Pulsatility • Need to determine approach for moving forward: • Main limitation currently is pulsation frequency • Ideas • Matching Reynold’s number (alter viscosity) to accommodate slowness • Add additional hardware (digitally controlled valve, other) to improve pulse frequency (temporal offset relative to pump) • Observe pressure wave with additional pump heads

  6. Looking Forward • Try to get laptop working • Allow us to run a true hydraulic permeability setup • Working on pulsatile flow • Ordering a container box • To allow for portability of hardware interface • Creating graphical user interface hardware select menu • Syringe pump control? • Battery powered surge protector? • Allow for continued usage when power goes out momentarily

  7. Gantt Chart