1 / 14

Conversion from Physical to Aerodynamic Diameters for Radioactive Aerosols

Conversion from Physical to Aerodynamic Diameters for Radioactive Aerosols . Jeffrey J. Whicker Los Alamos National Laboratory Health Physics Meeting 2007. Problem. Many articles provide data on the physical diameter of particles

edolie
Télécharger la présentation

Conversion from Physical to Aerodynamic Diameters for Radioactive Aerosols

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Conversion from Physical to Aerodynamic Diameters for Radioactive Aerosols Jeffrey J. Whicker Los Alamos National Laboratory Health Physics Meeting 2007

  2. Problem • Many articles provide data on the physical diameter of particles • Most inhalation dose models require information on aerodynamic diameters Aerodynamic Diameter Physical Diameter =

  3. Additional complications • Ranges of particle sizes for which conversion is needed can be huge • Reynolds numbers spanning 6 orders-of –magnitude • 3 different flow regions • The Stokes region • The transition region • Newton’s law region

  4. Definition of Aerodynamic Diameter • Aerodynamic diameter is the diameter of a unit density particle (1 gm/cm3) that has the same settling velocity as the particle. Physical diameter (Pu) Physical diameter (water) Equal settling velocities means equal aerodynamic diameters

  5. Calculation of terminal settling velocity in the Stokes region Formula for terminal settling velocity: Where:  = particle density (g cm-3) dp = physical diameter (cm) g = gravitational acceleration Cp = Cunningham correction factor  = viscosity  = shape correction factor

  6. Setting Vts equations equal and solving Physical diameter (Pu) Physical diameter (1 g/cm3) Equal settling velocities means equal aerodynamic diameters

  7. Cunningham Slip Correction problem Slip correction is needed because the particles are small enough to “slip” between air molecules without collision. Cp gets larger as the particle sizes decrease. Where: • is the mean free path between collisions with air molecules (0.066 m at 1 atm and 20oC)

  8. Equations show interdependency of particle diameter and Cunningham Slip Correction Solution: pick particle size (dp), solve for Cp, then solve right side of equation (set p=11.46 g cm-3, ae = 1 g cm-3,  = 1.5 (ICRP 66), then iteratively solve for dae

  9. Conversion in the transition regions (Re >1 but <1000)Include for larger particles greater than about 50 m Where: CD is the coefficient of drag Unfortunately, to calculate the Re you need VTS , and you need the VTS to calculate Re

  10. Independence of Re and Cd from Settling Velocity Solution: Re was determined using the above equation* then substituted into the equation below to calculate VTS *Using table 3.5 in Hinds (1985) Aerosol Technology: Properties, Behavior, and Measurement of Airborne Particles. John Wiley & Sons. New York, New York

  11. Conversion of dp to dae

  12. Conversion for really big particles (Re >1000, particle > 350 m) Coefficient of drag is relatively constant in the Newton’s region, so taking a ratio of the two terms above this reduces to:

  13. Useful relationship spanning all three Reynolds regions:

  14. Conclusions: • Equations were developed to convert physical diameters to aerodynamic diameters • Examples were provided for plutonium particles • BUT, this approach is valid for any particle with known density • The 2.8 (okay 3) rule for quick conversion of respirable particle sizes of plutonium • Simple relationships were developed for conversions of particle sizes that span over 6 orders of magnitude in Reynolds numbers (0.1 um up to 10,000 um diameters)

More Related