1 / 12

Chlorerede oløsningsmidler , Nyheder fra konferencen i Monterey

Chlorerede oløsningsmidler , Nyheder fra konferencen i Monterey. Kirsten Rügge , COWI Hvad er nyt på området? Hvad er i udvikling? Hvor ser det ud til, at vi er på rette vej? Og hvor skal vi prøve andre teknologier? Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden?.

ernie
Télécharger la présentation

Chlorerede oløsningsmidler , Nyheder fra konferencen i Monterey

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chloreredeoløsningsmidler, Nyheder fra konferencen i Monterey Kirsten Rügge, COWI • Hvad er nyt på området? • Hvad er i udvikling? • Hvor ser det ud til, at vi er på rette vej? • Og hvor skal vi prøve andre teknologier? • Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden? Monterey 2010

  2. COWIs deltagere Monterey 2010

  3. Enhance Vapor Intrusion Assessment and Mitigation Christopher C. Lutes (Christopher.Lutes@arcadis-us.com), Robert Uppencamp,and Carl Singer (ARCADIS U.S., Inc., NC, USA), Ronald Mosley and Dale Greenwell (U.S. EPA, Research Triangle Park, NC, USA) • Radon som tracer for chloreredeopløsningsmidler • Radon somværktøjtilfastlæggelseafkildeplacering • Radon somværktøjtiladskillelseafjordforureningogindendørskilder Monterey 2010

  4. Tracking Vapor Intrusion Pathways – An Active Tracer Gas Test Per Loll (pl@dmr.dk), Poul Larsen, and Claus Larsen (DMR A/S, Denmark) • Tracertesttilbestemmelseafspredningsveje for forureneing • Støttetilvalgafafværgemetode • Dokumentation for udførtafværge • Gas: 5% H2 og 95 %N2 • Billigthåndholdtmåleinstrument Monterey 2010

  5. VaporIntrusionModelingInfluence of BarometricPressureChangesonSoil Gas Concentrations Annette P. Mortensen and Anders G. Christensen (AGC@NIRAS.DK)(NIRAS A/S, Allerød, Denmark), Lillian D. Abreu1 and Neal Durant (Geosyntec, Baltimore, USA), Lizzi Andersen (COWI A/S,Lyngby, Denmark), Mette Christophersen (Region of Southern Denmark, Vejle, Denmark)1Now at Arcadis, San Francisco, USA. • Store variationervedgentagnemålingerafporeluft under gulvogindendørsihuse (op til 4 størrelsesordner) • Ændringeribarometertryk giver < 5% variation iporeluft, lidtstørreindendørs • Variationerskyldessandsynligvismåleusikkerhed Monterey 2010

  6. A New Quantitative Passive Sampler for VaporIntrusionAssessment:The PDMS Membrane Sampler Hester Groenevelt (hgroenevelt@geosyntec.com) and Todd McAlary, (Geosyntec Consultants, Inc., Ontario, Canada), TadeuszGórecki and Suresh Seethapathy (University of Waterloo, Ontario, Canada), Heidi Hayes (Air Toxics, Ltd., Folsom, CA). • Indeklimakoncentrationermålestypisk med "1 to 6 liter Summa canisters" fyldt over få minutter (for porelufttil 24 timer, for indeklimamålinger) • Waterloo sampleren, lillerørtilpassivopsamling over dage/uger • Nem at håndtere • Billig at analysere • Genbrugesikke Monterey 2010

  7. Using Multiple Lines of Evidence in a Vapor Intrusion Evaluation AmyGoldberg Day (Amy.GoldbergDay@Arcadis-US.com), (ARCADIS, Emeryville, California, USA) • Johnson & Ettingervapor transport model (2009) anvendt til at modellere indeklimakoncentrationer i en forretning i et center • Målte koncentrationer langt højere end modelleret • Renseri i centret • Konklusion: Godt at kende omgivelserne ! Monterey 2010

  8. Hvordan udføres indeklimamålinger • Momentan prøve • 8 timer • 24 timer • flere dage • Små variationer over året • 8-24 timers prøve tilstrækkelig Monterey 2010

  9. Postere og stande Monterey 2010

  10. -og møder Monterey 2010

  11. ZVI • Injektion af jern i forskellig størrelse • Hydraulisk frakturering meget anvendt • Dokumentationen måske ikke helt i top • Diskussion af brugen af nZVI ikke på programmet • Hvordan håndteres nZVI ? • Hvilke risici er der i forhold til miljøet ? • Hvordan influerer div. coatings på holdbarhed osv. ? Monterey 2010

  12. Chloreredeoløsningsmidler, Nyheder fra konferencen i Monterey • Hvad er nyt på området? • Hvad er i udvikling? • Hvor ser det ud til, at vi er på rette vej? • Og hvor skal vi prøve andre teknologier? • Hvilke spændende udfordringer kunne vi overveje at tage op i fremtiden? Monterey 2010

More Related