1 / 19

PMU (Programmable Monitoring Unit)

PMU (Programmable Monitoring Unit). LG PLC. LG Industrial Systems. PMU Lineup. PMU-830 12.1 ”. PMU x30 Series. PMU-730 10.4 ”. PMU-530 7.5 ”. PMU-830TT. PMU-330 5.7 ”. PMU-730TT. PMU-730ST. PMU-530ST. PMU-330TT. PMU-330ST. PMU-330BT. PMU x30 Series. PMU-330. PMU-530.

findlay
Télécharger la présentation

PMU (Programmable Monitoring Unit)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PMU(Programmable Monitoring Unit) LG PLC LG Industrial Systems

  2. PMU Lineup PMU-830 12.1” PMU x30 Series PMU-730 10.4” PMU-530 7.5” PMU-830TT PMU-330 5.7” PMU-730TT PMU-730ST PMU-530ST PMU-330TT PMU-330ST PMU-330BT

  3. PMU x30 Series PMU-330 PMU-530 PMU-330TT PMU-330ST PMU-330BT PMU-530ST • 320 x 240 dot, 5.5”/5.7” • 32 bit RISC CPU • Display Element • 256 Color TFT (PMU330TT) • 256 Color STN (PMU330ST) • Blue & White STN (PMU330BT) • Matrix touch-key: 16x12/screen • Various bitmap functions • bitmap touch/lamp, background bitmap • O/S downloading for version upgrade • Flash Memory (screen: 1MB/2MB) • Internal 256K SRAM (data logging/recipe) • RS-232C/422 comm. port • Waterproof (IP65F) • Size: 206 x 136 x 64 (Panel cut: 198 x 128) • Power: 21 ~ 28V DC • 640 x 480 dot, 7.5” • 32 bit RISC CPU • 256 Color STN • Analog touch-key: 640x480 • Various bitmap functions • bitmap touch/lamp, background bitmap • O/S downloading for version upgrade • Flash Memory (screen: 2MB) • Internal 256B SRAM (data logging/recipe) • RS-232C/422 comm. port • Waterproof (IP65F) • Size: 240 x 170 x 62 (Panel cut: 231 x 161) • Power: 21 ~ 28V DC

  4. PMU-x30 Series PMU 730 PMU 830 PMU-730TT PMU-730ST PMU-830TT • 640 x 480 dot, 10.4” • 32 bit RISC CPU • Display Element • 256 Color TFT (PMU 730TT) • 256 Color STN (PMU 730ST) • Matrix touch-key: 32 x 24/screen • Various bitmap functions • bitmap touch/lamp, background bitmap • O/S downloading for version upgrade • Flash Memory (screen: 2MB/4MB) • Internal 256K SRAM (data logging/recipe) • RS-232C/422 comm. & printer port • Waterproof (IP65F) • Size: 305 x 239 x 55 (Panel cut: 294 x 228) • Power: 85 ~ 265V AC (Free) • 800 x 600 dot, 12.1” • 32 bit RISC CPU • 256 Color TFT • Analog touch-key: 800x600 • Various bitmap functions • bitmap touch/lamp, background bitmap • O/S downloading for version upgrade • Flash Memory (screen: 4MB) • Internal 256K SRAM (data logging/recipe) • RS-232C/422 comm. & printer port • Waterproof (IP65F) • Size: 305 x 239 x 55 (Panel cut: 294 x 228) • Power: 85~265V AC (Free)

  5. Data from PLC or controller can be displayed after calculation Displays data with 8 different colours depending on the numeric range variance Numeric & String Display Numeric data display: DEC, HEX, BCD type ASCII CODE, read from PLC or controller, can be displayed with characters

  6. Data input using TENKEY PASSWORD encrypted Data Setting & Clock Display ★ Key display tag Min/max value of data setting & input range limit available ★ Clock Display RTC data display (year, month, date, hour, minute, second) using RTC element embedded in PMU

  7. Touch Function ★ TOUCH Input function: commands PLC touching a specific region on screen Bitmap touch: Displays different bitmaps according to the device status (ON/OFF) after Touch button operation Caption: Displays 2 letters according to the device status (ON/OFF) after Touch button operation Touch colour: Lamp function embedded in Touch button displays the devices status (ON/OFF) after Touch button operation Maximum 10 functions can be set up with one Touch tag

  8. Lamp Function ★ LAMP Tag: displays ON/OFF information of a bit in colour/picture Bitmap lamp: Displays different bitmaps according to the device status (ON/OFF) Caption function: Displays different letters according to the device status (ON/OFF) Data lamp: Displays lamp with 8 colours according to data range

  9. TREND graph - Input value change is visually shown with the time axis - 10 data can be set up with one graph - Logging data and recipe data trend available Others – bar graph, X/Y chart Graph Meter graph - Sets the lowest/highest value of data and displays current data in rate - Analog data (voltage, current) display

  10. Running data of each work are stored in PMU and when work changes, they are batch-transferred to the controller Easy to operate: converts the setup data into EXCEL format Recipe (parameter moving)

  11. Data Logging Data generated during operation are stored in PMU through periodic or conditional data logging Condition setting Operation setting Convenient to report: converts logging data into an EXCEL report DATA LOGGING screen

  12. Various Bitmap Functions Background bitmap function: Uses a background bitmap of the same screen resolution Transparent bitmap and lettering functions: Does not display the unnecessary part of bitmap and background letters No limit in size: Available to register regardless of bitmap size (only to be smaller than screen size) Image Character: All fonts available as long as WINDOWS support

  13. Simulation Functions Simulates the status of each device's address operation and communication while disconnected with PLC. Monitors data when you turn on each address or input data. RS-232C Simulation on drawing: If the status of a bit tag (ON/OFF) changes while drawing the screen, the screen changes can be displayed on PC monitor

  14. Convenient Memory Management Overall display of PLC address registered in the screen Overall change available in PLC address change Display of PLC address of tags registered in the screen Overall display of the contents of screen User-defined library registration

  15. PMU Communication 1:N Communication Connecting more than one PLCs to one PMU through RS-422/485 communication 1:1 Serial Communication One PLC connection to one PMU RS-422/485 500m MAX RS-232C 15m MAX. • 1:N communication by using RS-422/485 • should be organised as choosing identical • PLC types

  16. PMU Communication N:1, N:M (N+M ≤ 64) Communication Using MASTER-K/GLOFA-GM Fnet module Fnet 64 stations, 750m MAX. Enet option module installed in PMU MASTER-K GLOFA-GM (GㅁL-FUEA)

  17. PMU Communication PLC Communication with other devices Controls two different PLCs using one PMU 2nd comm. Ch. RS-232C Main comm. Ch. RS-232C/422/485

  18. Applicable Equipments

  19. PMU Option Maker Type Model name Loader Link PMU830 PMU730 PMU530 PMU330 PMU710 PMU320 Built-in serial comm. AB PLC SLC500[5/03,04] O - PLC-5 O - Yaskawa PLC Progic-8 O - MP-920 O - CP-9200SH O - Modicon PLC Modbus KDT PLC Cymon O O Koyo PLC DL-205/305/405 - O GE Fanuc PLC 90-30[SNP-X] O - POSCON PLC POSFA phld-1a/2a - O Yokokawa PLC FA-M3 - O Delta PLC DVP-ES - O PMUㅁㅁㅁ-F LGIS PLC MASTER-K GㅁL-FUEA GLOFA-GM GㅁL-FUEA PMUㅁㅁㅁ-E Ethernet Under development CC Link PMUㅁㅁㅁ-C Applicable Equipments