1 / 12

2020 DELL EMC DEE-1721 Real Exam Dumps DumpsBase

2020 DELL EMC DEE-1721 Real Exam Dumps DumpsBase. DumpsBase DEE-1721 dumps questions are nicely organized and reputable preparation way that covers every single topic from the DELL EMC DEE-1721 exam. DELL EMC DEE-1721 exam dumps questions enable you to clear the DEE-1721 Expert u2013 Implementation Engineer, SC Series Exam smootly.

Télécharger la présentation

2020 DELL EMC DEE-1721 Real Exam Dumps DumpsBase

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DEE-1721 Expert – Implementation Engineer, SC Series Exam

  2. Question NO.1 A company has multiple Storage Centers at their primary site and a disaster recovery system at their remote site. Because there company has an important volume that request high availability protection, an outage on one system at the primary location must not cause data to be inaccessible. In addition, disaster recovery protection is required to protect data even if the primary site goes down. Which recommended technology meets these requirements? A. Live Volume Managed Replication B. Fluid Data Architecture C. Synchronous Replication D. Asynchronous Replication Answer: A

  3. Question NO.2 During the deployment of an SC Series storage array, the redundancy of a tier may be restricted dual redundancy. What is the cause for this behavior? A. Depending on the drive firmware level and drive sire, Dell Storage Manager will enforce dual redundancy B. Depending on the drive speed, drive sire, and SCOS version, dual redundancy may be enforced C. Depending on the drive manufacturer and SCOS version, Del Storage Manager will enlace dual redundancy D. Depending on the number of spares configured on the system and SCOS version, dual redundancy may be enforced Answer: B

  4. Question NO.3 A storage administration needs to enable regular Data Progression to move data between storage tiers. While navigating through the Volume Create wizard, which storage profile should be selected? A. Low Priority B. Medium Priority C. High Priority D. Recommended Answer: C

  5. Question NO.4 A storage administrator wants to perform an SCOS update to SCOS version 6.7.5. The SC Series is currently at SCOS version 6.5.30. The SC Series storage array is located at a secure facility and does not allow connectivity to any network outside the facility. The Administrator is attempting to use the Storage Center Update Utility to accomplish this task but has been unsuccessful. What is the reason for this Issue? A. Storage Center has not passed pre-upgrade checks and is blocking the update B. Storage Center is not at the minimum required SCOS version to use the utility C. Storage Center is not licensed to use the Storage Center Updated Utility D. Secure facility is not allowing the administrator’s laptop to connect to the Storage Center across the network. Answer: B

  6. Question NO.5 After configuring a new SC4020, you receive an alert that all disks are only seen on one path. What are the reasons for the alert? A. Both SAS cables are defective and the alert definition was configured incorrectly. B. One SAS cable was not connected between the controllers and the alert definition was configured incorrectly. C. One SAS cable was not connected between the controllers and one SAS cable is defective D. One SAS cable is defective and the other path to the disks was not managed Answer: B

  7. Question NO.6 You added an existing Storage Center to an instance of Dell Storage Manager using the Volume Manger user. You are able to map volumes in the 10K folder to the servers but not the volumes in the SSD folder. What is the reason for this issue? A. Only the Administrator user can map volumes in the SSD folder. B. Volume Manager user can only access one disk folder C. Volume Manager user is a member of a group that is restricted from the SSD folder D. Servers cannot detect SSD drives Answer: B

  8. Question NO.7 Which processes should be used when testing controller failover on a newly installed Storage Center? A. Start server IO to a volume, restart a controller, then rebalance ports and ensure no IO errors. B. Start server IO to a volume, restart either controller, and ensure no IO errors are reported. C. Start server IO to volumes owned on each controller, restart the controllers sequentially, and ensure no IO error. D. Start server IO to volumes owned on each controller, restart the controllers simutaneously, and ensure no IO error. Answer: D

  9. Question NO.8 A storage administrator has multiple servers connected to the Storage Center through two iSCSI networks. You use a software iSCSI Initiator on the servers and the Storage Center runs in Virtual Port Mode. Which IP address is required in the iSCSI Initiator for proper connectivity? A. Primary IP address for each domain B. Control Port IP address for each domain C. Reserve IP address for each domain D. Management IP address of each controller Answer: B

  10. Question NO.9 Several servers connected to the Storage Center through FC fabrics using WWN zoning. You recently replaced a server’s FC HBA; however, the server no longer connects to the Storage Center. What is causing this issue? A. Storage Cento fault domains must be updated with the new HBA WWN B. Storage Center fault domains must be converted to Virtual Pat Node C. Server's zone must be updated with the new switch port to which the HBA is connected D. Server's zone must be updated with the new NBA WWN Answer: D

  11. Question NO.10 A site has multiple storage administrators. Some administrators need to be limited to manage only specific volumes. The administrator should be able to create and present volumes within the administrator's area. Those administrators should NOT be able to see any other volumes created in the Storage Center. How should the deployment engineer accomplish tins task? A.Grant the administrator Volume Manager access. Create server folders and move the desired volumes into them, then assign the server folder to the desired administrator. B.Grant the administrator Admin user access. Create server folders and move the desired volumes into them then assign the server folder to the desired administrator. C.Grant the administrator Volume Manager access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator. D.Grant the administrator Admin user access. Create volume folders and move the desired volumes into them, then assign the volume folder to the desired administrator. Answer: D