1 / 11

Muon momentum scale calibration with J/y peak

Muon momentum scale calibration with J/y peak. PRELIMINARY: low statistics in data not final MC (low stat used). First pass on the data: many details to be investigated. Samples and cuts. Data (~15 nb -1 ):. May6 Re-Reco from 132440 to 134725 Onia-CS-V9 up to 135735

gareth
Télécharger la présentation

Muon momentum scale calibration with J/y peak

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Muon momentum scale calibration with J/y peak PRELIMINARY: low statistics in data not final MC (low stat used) First pass on the data: many details to be investigated

  2. Samples and cuts • Data (~15 nb-1): May6 Re-Reco from 132440 to 134725 Onia-CS-V9 up to 135735 Mu-CS-V1 up to 136086 (CMSSW_3_5_8_patch3) Mu-CS-V2 up to 136561 (max useful 136297) (CMSSW_3_6_1_patch2) BPH Json file applied • MC (~100 nb-1): Spring10 J/y prompt + ppMuMuX • Standard onia selection: global muon: nHits inner track > 11 tracker muon: nHits inner track > 11 pixelLayer >1 pixelLayer >1 d0<5 cm, |dZ|<20 cm d0<5 cm, |dZ|<20 cm chi2 < 5 chi2 < 20 TMLastStationAngTight Exclusive cathegories: glb-glb if any, otherwise glb-trk (inner track always used, also for glb muons) No trigger, no acceptance cuts

  3. Mass peak (nominal mass 3.0969 GeV) Fit: CrystalBall (to include FSR tail) + exponential for the background DATA: mean (3.092 ± 0.001) GeV MC: mean (3.0976 ± 0.0006) GeV sigma (43 ± 1) MeV sigma (37.3 ± 5) MeV Data have 5MeV bias and worse resolution (and larger background)… … BUT the pT, h distribution of J/y is quite different in data and MC (to be checked)

  4. Mass reso VS muon kinematics data data |h| 1.6 MC MC pT 1.4 GeV |h| 0 pT 4.6 GeV

  5. Mass scale VS muon kinematics MC (1.38 pb-1 Spring10 prompt J/y) • Also in MC we have scale bias • bias in the reco algorithm • approximated material budget in reconstruction • Gaussian fit in each pT, h bin: bias < 5 MeV • FSR not considered (→ CB with more stat) • bins are large: integration over different eta/pt distribution btw data and MC

  6. Inner VS global tracks GG+GT GG: inner tracks GG: global tracks No significative difference with this statistics

  7. peak+FSR convoluted with gaussian for resolution MuScle fit (FSR from fit of generated mass distribution) • Fit reconstructed mass profile with signal model + exponential background • ansatz functions for single muon scale and reso • compute m, s(m) (with error propagation) event by event • unbinned likelihood multiparameter fit → two muons can probe uncorrelated detector regions → correlation between different kinematic variables taken into account extract scale and resolution on single track as a function of muon kinematics a0 = 1.0019 ± 0.0008 2‰ effect a1 = (-4 ± 2)·10-4 GeV-1 1‰ at 3 GeV b0 = 1.66 ± 0.09 b1 = (5.8 ± 0.9)·10-3 b2 = (2.1 ± 0.2)·10-2 bad fit for high h parabola (to be checked with more stat) b3 = (3 ± 3)·10-2 b4 = 1.8 ± 0.3

  8. Mass after corrections Raw Calibrated m = 3.092 ± 0.001 m =3.094± 0.001

  9. Crystal Ball is an approximation • Model computed analytically: fit to the generated mass spectrum gaussian for the resolution 2D model mass VS s peak shift at high s • If you fit this model with Crystal Ball → 2MeV shift in the mean

  10. Resolution: PRELIMINARY • Resolution from MuScle fit • !! large uncertainties not plotted !! • hints of worse resolution in dat at high h(confirmed by plot in slide 4) DATA s(M) GeV • Width of gaussian fit in each f bin • sinusoidal shape (??) mu - mu + 42±1 MeV c0 45±1 MeV c1 -4±2 MeV -4±2 MeV c2 1.5±0.5 0.5±0.5

  11. Final aims • Commissioning: • measure pT resolution from data and compare with MC • measure scale bias in data → provide corrections → compare with expected effects from misaligment, magnetic field, material budget (tested in MC) • Usage in physics analyses: • onia ds/dpT measured with corrected momenta → remaining systematics due to correction uncertainty • systematics on onia acceptance due to different MC-data scale and resolution (full scale bias in MC + data uncertainty) used for systematics (difference in resolution between data and MC + data uncertainty) used for systematics • VBTF: extrapolation of results to Z