1 / 16

Fl emish SMP and inspection tool

Fl emish SMP and inspection tool. Brussels , June 17 th 2010 Paul W.Verspoor MBA. Flemish legal situation. Operators: anual ‘VOC document’ Demonstrate compliance SED and some additional ELV’s Send to authorities : if requested Content ‘VOC document’: not specified. The project.

gayora
Télécharger la présentation

Fl emish SMP and inspection tool

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Flemish SMP and inspection tool Brussels, June 17th 2010 Paul W.Verspoor MBA

  2. Flemishlegalsituation • Operators: anual ‘VOC document’ • Demonstratecompliance SED and someadditionalELV’s • Send to authorities: ifrequested • Content ‘VOC document’: notspecified

  3. The project • Clarifications & Answers to FAQ on SED • Alsoavailable in English • (Google: EsvoccgFrequentlyaskedquestions SED) • Studyexisting VOC documents • Makeinspectionseasier • Idea: Standardise SMP forcertainactivities

  4. Existing VOC documents • Industrystandards & Individual operators • Widely different • Impossible to inspectefficiently • Non paidattention to uncertainties • Project • Guideline ‘VOC document’ for all activities • Inspectionmanual

  5. Guideline VOC document • Comprehensive list of required content • Onlypartsapply in individual cases • Help to find relevant sectionsonly • Questionsthat must beanswered • For everythinkablesituations • Adressesuncertainties • Per SMP item & overall

  6. Inspectionmanual • Three stage approach • Analysis of VOC document • Requireadditionalinformation (ifnecessary) • On site inspection (ifnecessary) • Manual • Guideline+ inspectioninstructions • Every item in guideline

  7. Required Content • Description of the installation and background information • ELV’s and otherrestrictions • Actualemissions • Accuracy of the SMP

  8. Examplechapter 2:ELV’sand otherrestrictions

  9. Example§ 2.6 Reduction plan coating processes • Remarks: • Onlyforactivities in table Annex IIb • Notforactivitieswithtotalemission limit value • Notfor ‘Heatset’ and ‘Othercleaning’ • Requirements • Addcopy of Reduction plan • Calculate ‘Referenceemission’ and ‘Target emission’ cf Annex IIb (t/a)

  10. Inspector’sguidance§ 2.6 Reduction plan coating processes • Are the multiplication factors correct? • Referenceemission • Target emission • Table in Annex IIb

  11. ExampleSolvent balance I1 • I1: Input, purchased • Provide clearoverview of the calculation • Indicatehowchanges in stock have been handled • Provide percentages of solvent in preparations • Provide source of informationfor percentages • Whatspecificmass was usedforeach solvent

  12. InspectorguidanceI1: Input, purchased • Calculationunderstandable? • Calculation correct? • Handling of stock changes present? • Specificmass correct? • Source of informationclear?

  13. ExampleAccuracy O6 & O8 • O6 waste, O8 reusedexternally • Assume O6 and O8 = 0 • Stillcompliant: OK • Ifnotcompliant,indicate: • howmeasured (add copies) • how solvent content determined (add copies) • Estimateinaccuracy, calculate worst case

  14. Accuracytotal SMP • Calculateemissionswith all worst cases • Whereinaccuranciescannotcoincideindicatewhy • Ifstillcompliant: OK • Ifno more compliant: • Either: improveaccuracy of largest contribuant • Or: demonstratecombination of all worst cases willnotoccur

  15. Estimation O1Waste gas emissionsfromabatement • Estimate part solvent to abatement • Example: input – fugitives –O6/8 • 1000 t – 150t – 75t = 780 t • Determine average ‘notabated’ • Design parameters or recent measurements • Example: ‘in’: 3 g/m³, ‘out’: 50 mg/m³ • 50/3000 = 1,7% • Calculate O1: 780 t x 1,7% = 13 t

  16. Thank you for your attention Paul W.Verspoor MBAverspoor@sitmae.nl+31.346.562.414