1 / 20

James D. Christensen, Ph.D. IU School of Medicine

BME 595 - Medical Imaging Applications Part 2: INTRODUCTION TO MRI Lecture 3 Multi-Dimensional Imaging Feb. 28, 2005. James D. Christensen, Ph.D. IU School of Medicine Department of Radiology Research II building, E002C jadchris@iupui.edu 317-274-3815. References.

gerda
Télécharger la présentation

James D. Christensen, Ph.D. IU School of Medicine

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BME 595 - Medical Imaging ApplicationsPart 2: INTRODUCTION TO MRILecture 3 Multi-Dimensional ImagingFeb. 28, 2005 James D. Christensen, Ph.D. IU School of Medicine Department of RadiologyResearch II building, E002C jadchris@iupui.edu317-274-3815

  2. References Online resources for introductory review of MRI physics: • Robert Cox’s book chapters online • http://afni.nimh.nih.gov/afni/edu/ • See “Background Information on MRI” section • Mark Cohen’s intro Basic MR Physics slides • http://porkpie.loni.ucla.edu/BMD_HTML/SharedCode/MiscShared.html • Douglas Noll’s Primer on MRI and Functional MRI • http://www.bme.umich.edu/~dnoll/primer2.pdf • Joseph Hornak’s Web Tutorial, The Basics of MRI • http://www.cis.rit.edu/htbooks/mri/mri-main.htm Book covering Multi-Dimensional MRI: • E. Mark Haacke, et al. Magnetic Resonance Imaging: Physical Principles and Sequence Design, 1999.

  3. Phase-Encoding

  4. 2D Gradient-Echo Pulse Sequence (a)

  5. 2D Gradient-Echo Pulse Sequence (b)

  6. 2D Gradient-Echo K-Space

  7. Multi-Slice 2D Pulse Sequence

  8. Multi-Slice 2D Slice Excitation

  9. 2D Echo-Planar Imaging (EPI) Pulse Sequence K-Space Trajectory

  10. 3D Gradient-Echo Pulse Sequence Phase Spoiling: (RF or gradients) causes Incoherence in transverse magnetization

  11. Fast-Imaging(Steady-State Incoherent pulse sequence) For a train of RF pulses repeated every TR seconds The steady-state equilibrium magnetization is where The transverse magnetization following the nth RF pulse is The Steady-State Incoherent signal intensity is proportional to M

  12. Flip Angle (θ), TR & T1 in Fast Imaging where Steady-State Incoherent (SSI) signal intensity:

  13. Flip Angle (θ), TR & T1 in Fast Imaging where

  14. Steady-State Coherence Pulse Sequence

  15. Steady-State Coherence Pulse Sequence

  16. Chemical-Shift Imaging (CSI)

  17. Chemical-Shift Imaging (CSI)

  18. Chemical-Shift Imaging (CSI)

  19. Chemical-Shift Imaging (CSI)

  20. Homework Problem 1