1 / 8

Calo meeting – 02/05/2009

Calo meeting – 02/05/2009. Calorimeter. simulation. tuning. for MC09. Olivier Deschamps LPC Clermont-Fd. Tuning calo parameters for simulation. Purpose Tune calo parameters for simulation/digitisation against new G4

gili
Télécharger la présentation

Calo meeting – 02/05/2009

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Calo meeting – 02/05/2009 Calorimeter simulation tuning for MC09 Olivier Deschamps LPC Clermont-Fd

  2. Tuning calo parameters for simulation • Purpose • Tune calo parameters for simulation/digitisation against new G4 • Possibly sizeable changes as there is major change in EM model in G4 v8 • Which paramaters to be tuned ? • Spd threshold is defined as a fraction of MIP • Preshower ADC dynamics defined as 100 MIPs •  condDB parameters used at the digitization level •  both depend on the actual MIP deposit in MeV • Ecal and Hcal activeToTotal ratio •  Used in Boole to convert MC total energy deposit into ADC • ADC = (ActiveToTotal * visibleEnergy)/Gain • Parameters to be set as conditions in condDB (XCal/Calibration/Gain.xml) 2

  3. Available MC • MC validation sample • Use PGUN pions and electrons • Various energies from 100 MeV to 168 GeV • 3 configurations : • MC2008 : LHEP + EM option1 + DRay off + KineHT • MC2008HT : LHEP + EM option1 + DRay on + KineHT • MC2008LT : LHEP + EM option1 + DRay on + KineLT • LHEP parameterised modeling of hadronic interactions (G4) • EM option1 EM processes using parameters optimised for better CPU performance at the cost slightly less precise physics (G4) • DRay off production cuts as follow: e- 10 km, e+ 5 mm, gamma 10 mm (G4) • DRay on production cuts as follow: e- 5 mm, e+ 5 mm, gamma 5 mm (G4) • KineHT tracking cuts (kinetic E) as follow: hadrons/mu+/mu- 10 MeV, e+/e-/gamma 1 MeV, others none (Gauss) • KineLT tracking cuts (kinetic E) as follow: hadrons/mu+/mu- 1 MeV, e+/e-/gamma 0.1 MeV, others none (Gauss) • Apply a minimal selection on PGUN particles: • no showering before calo • small deposit in Hcal when looking electrons into Ecal • small deposit in Ecal when looking pions into HCal 2

  4. MIP deposit DC06 MC2008 deposit (MeV) • MIP peak position in Prs/Spd scintillator plane : 2.74 MeV • Increased by 17% wrt to DC06 (was 2.35 MeV) •  Prs dynamics in condDB : 235 -> 274 MeV •  keep Spd threshold unchanged in condDB ~ 0.6 MIP (~0.7 MIP in DC06) 3

  5. Prs visible energy PGUN electron 34 GeV (MC2008) Gauss v24r1 <Evis> = 0.14 GeV DC06 <Evis> = 0.16 GeV DC04 • Increase of the Prs • visible energy ~ +14% wrt to DC06 4

  6. ActiveToTotal for Ecal 2008 2008HT 2008LT • Evis = a Etot (+b) • a-1 provides the ActiveToTotal ratio for condDB • b non consistent with 0 due to energy loss before Ecal Ecal Total/Active decreases by 15% wrt to DC06 5

  7. ActiveToTotal for Hcal 2008 2008HT 2008LT Hcal Total/Active decreases by 30% wrt to DC06 6

  8. Summary • New condDB parameters for MC2008/2009 • significant change wrt DC06 in MIP deposit and Xcal visible energy • use ‘mc2008’ configuration as standard to update ActiveToTotal ratio • and Prs dynamics range in conDB • condDB update with the new value • A 2nd round of validation sample is being produced with the new setting • electron/pion/photon/pi0 with no material in front of Calo • will allow more detailed analysis and check the value are OK • Also produced : some reference channel for tuning reconstruction and PID • Rhopi / PhiGamma / J/Psi(ee,mm)Phi • Next to be checked/re-tuned • photon/electron reconstruction parameters : S-shape, fine energy correction • calo PID reference PDF • To be done with new MC data produced with the correct energy scale 7