1 / 23

Enzyme Activity

Enzyme Activity. MALIK ALQUB MD. PHD. Information from enzymes measurements in serum. Presence of disease Organs involved Aetiology /nature of disease: differential diagnosis Extent of disease-more damaged cells-more leaked enzymes in blood Time course of disease.

goldy
Télécharger la présentation

Enzyme Activity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Enzyme Activity MALIK ALQUB MD. PHD.

  2. Information from enzymes measurements in serum • Presence of disease • Organs involved • Aetiology /nature of disease: differential diagnosis • Extent of disease-more damaged cells-more leaked enzymes in blood • Time course of disease

  3. Enzymes routinely measured

  4. ALANINE TRANSAMINASE (ALT) AND ASPARTATE TRANSAMINASE( AST) - Oxoglutarate + L-alanine - Oxoglutarate + L-aspartate Alanineaminotransferase (ALT) Aspartateaminotransferase (AST) L- glutamate + oxaloacetate L - glutamate + pyruvate • Alaninetransaminase (ALT) and Aspartatetransaminase (AST) enzymes are the most abundantly present in the liver and is elevated in blood as a result of leakage from damaged cells • Measurement of these transaminases is useful for the diagnosis of liver diseases • In viral hepatitis the enzyme levels are increased 20-50 times above the upper limit of the normal range • Alaninetransaminase (ALT) increase is specific for liver damage involving hepatocellular damage • Aspartatetransaminase (AST) is moderately increased in Muscular dystrophy and acute myocardial infarction

  5. ALKALINE PHOSPHATASE (ALP) • Is a group of enzymes that have maximal activity at a high pH 9.0-10.5 • Widely distributed throughout the body • High levels are seen is liver, bone, placenta and intestine and useful to assess hepatobiliary and bone diseases • In hepatobiliaryobstruction,hepatocytes lining the biliary ducts induces the ALP synthesis. • High levels of ALP is indicative of extrahepatic obstruction rather than intrahepatic obstruction • In bones, the enzyme is derived from osteoblasts. Hence increased in bone diseases like rickets, osteomalacia, neoplastic diseases with bone metastates and healing fractures

  6. Isoenzymes • catalysesame reactions but are formed from structurally different polypeptides. • They perform the same catalytic function. • Different isoenzymes may arise from different tissues and their specific detection may give clues to the site of pathology. • Various isoenzymes of an enzyme can differ in three major ways: • - enzymatic properties • - physical properties (e.g heat stability) • - biochemical properties such as amino acid composition and immunological reactivities.

  7. CREATINE KINASE (CK) Creatine + ATP phosphocreatine + ADP (Phosphocreatine – serves as energy reserve during muscle contraction) • Creatinekinase is a dimer made of 2 monomers occurs in the tissues • Skeletal muscle contains M subunit, Brain contains B subunits • Three different isoenzymes are formed

  8. LACTATE DEHYDROGENASE (LDH) Pyruvate Lactate (anaerobic glycolysis) • LDH is elevated in myocardial infarction, blood disorders • It is a tetrameric protein and made of two types of subunits namely H = Heart, M = skeletal muscle • It exists as 5 different isoenzymes with various combinations of H and M subunits

  9. Methods for Enzyme measurement • Fixed time methods • the reactants are combined, • the reaction proceeds for a designated time, • the reaction is stopped (usually by inactivating the enzyme with a weak acid), • a measurement is made of the amount of reaction that has occurred. • The reaction is assumed to be linear over the reaction time; the larger the reaction, the more enzyme is present. • Possible problems with extremely high enzyme levels

  10. Methods for Enzyme measurement • Continuous-monitoring methods • multiple measurements, usually of absorbance change, are made during the reaction, • either at specific time intervals (usually every 30 or 60 seconds) • or continuously by a continuous-recording spectrophotometer. • These assays are advantageous over fixed-time methods because the linearity of the reaction may be more adequately verified.

  11. Methods for Enzyme measurement • Continuous-monitoring methods (Kinetic assay) • If absorbance is measured at intervals, several data points are necessary to increase the accuracy of linearity assessment. • Continuous measurements are preferred because any deviation from linearity is readily observable.

  12. Calculation of Enzyme Activity • Common unit is International unit or IU/L • Conditions to be maintained • pH • Temperature • Substrate

  13. Reporting Enzyme Activity • Enzyme concentration is best measured by its activity or its rate of activity by observing • Substrate depletion • Product production • Increase/decrease in cofactor/coenzyme

  14. Measurement Units • Reported as “activity” not concentration • IU = amount of enzyme that will convert 1 μmol of substrate per minute in specified conditions • Usually reported in IU per liter (IU / L) • SI unit = Katal = mol/sec • moles of substrate converted per second • enzyme reported as katals per liter (kat / L) • 1 IU = 17nkat

  15. Measurement of Enzyme Mass • Immunoassay methodologies that quantify enzyme concentration by mass are also available and are routinely used for quantification of some enzymes. • Immunoassays may overestimate active enzyme as a result of: • possible cross-reactivity with inactive enzymes, • inactive isoenzymes, • or partially digested enzyme.

  16. Measurement of Enzyme Mass • The relationship between enzyme activity and enzyme quantity is generally linear but should be determined for each enzyme. • Enzymes may also be determined and quantified by electrophoresis techniques which provide resolution of isoenzymes.

  17. LDH • Colorimetric • Spectrophotometric method makes use of NADH to NAD coenzyme change in reaction

  18. LDH

  19. AST • Coupled reaction • Measured at 340 nm • L-aspartate + alpha- oxoglutarateoxaloacetate + glutamate • Oxaloacetate + NADH + H+malate +NAD+ AST

  20. AST