1 / 30

ASTROSAT Prospects for a Hard X-ray Survey

ASTROSAT Overview LAXPC Details Science Prospects Hard X-ray Survey Prospects Beyond ASTROSAT Biswajit Paul Raman Research Institute, Bangalore. ASTROSAT Prospects for a Hard X-ray Survey. ASTROSAT. IXAE. EXOSAT-ME : 1983-1986 1.5-15 keV , 1800 sq cm With LE Imaging Telescopes (CMA)

gomer
Télécharger la présentation

ASTROSAT Prospects for a Hard X-ray Survey

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ASTROSAT Overview LAXPC Details Science Prospects Hard X-ray Survey Prospects Beyond ASTROSAT Biswajit Paul Raman Research Institute, Bangalore ASTROSATProspects for a Hard X-ray Survey

  2. ASTROSAT

  3. IXAE

  4. EXOSAT-ME : 1983-1986 1.5-15 keV, 1800 sq cm With LE Imaging Telescopes (CMA) GINGA-LAC: 1987-1991 2-37 keV, 4000 sq cm With All Sky Monitor RXTE-PCA: 1996-201? 2-30 keV, 6000 sq cm With All Sky Monitor and Hard X-ray Instrument ASTROSAT-LAXPC: 2-80 keV, 6000 sq cm With All Sky Monitor, Soft/Hard X-ray Instruments, UVIT Large Area X-ray Astronomical Observatories USA Exp,2000 sq cm IXAE, 1200 sq cm

  5. LAXPC Characteristics Area : 6,000 - 7,500 cm2 Mass: 390 kg Time Resolution: 10 µs, dead time 10-35 µs Absolute Timing Accuracy: 10 µs Front-end and Processing Electronics: separate electronics for each detector Data Storage: Onboard Memory 570 MB per Orbit Detection Efficiency: 90-100 % upto 20 keV, ~40% upto 80 keV Energy Resolution: 12-13% at 20-60 keV Life Time: 3-10 Years, no Consumable

  6. LAXPC: Effective Area

  7. LAXPC: Complex Energy Response • Energy response generation: Monte Carlo simulation / Ground calibration

  8. LAXPC: Energy resolution

  9. Spectral Leakage in PCA and LAXPC LAXPC PCA

  10. Spectral Leakage in PCA

  11. LAXPC Schematic

  12. LAXPC: Complex Energy Response PCA: Energy resolution of single events and escape events

  13. ASTROSAT Ground Trace

  14. LAXPC Advantages Large effective area in hard X-ray band Stable background Low Spectral leakage Wide energy band 2-80 keV with LAXPC 0.3-8 keV with SXT 10-150 keV with CZT Simultaneous, sensitive, multi-band UV/Optical observations Only timing instrument it this time frame

  15. CRSF with ASTROSAT LAXPCs

  16. Hard X-ray QPOs

  17. Long term intensity variations in Cen X-3

  18. Long term intensity variations and the orbital modulation Raichur & Paul 2008

  19. Cen X-3: Precessing Warped Accretion Disk ?? Raichur & Paul 2008

  20. Cen X-3: Precessing Warped Accretion Disk ?? Raichur & Paul 2008

  21. Cen X-3: Intensity dependence of the pulsed fraction Raichur & Paul 2008

  22. Long term intensity variations in Cen X-3and the quasi-periodic oscillations Harhsa et al. 2008

  23. Long term intensity variations in Cen X-3and the quasi-periodic oscillations Raichur & Paul 2008

  24. Hard X-ray Survey Explore the 10-60 keV band Period ic Scan Galactic plane + SMC region Extragalactic Survey 100 x 100 degree Survey with Slew Data Example: RXTE-PCA

  25. Survey with Slew Data

  26. Survey with Slew Data

  27. X-ray Polarimeter

  28. POLIX: Sensitivity MDP(n) =(n/S) (2(S+B)/T) 1/2 GEMS

More Related