An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Choice of the cleanroom Laser specifications  class 10,000 a) Hard wall cleanroom b) Softwall cleanroom Entire room = cleanroom Laser size = cleanroom • - Special hard wall, • Powerfull filter, • Special clothing • Movable: used in H4/USC55 • best control Entire room = cleanroom

  2. Softwall cleanroom  customer design 2.4 m With FFU 1.3 m 1.9 m Main problem:safety agreement for curtain TIS approval for one industrial product (non-transparency) One company agree to apply it.

  3. Fan filter unit (FFU): 2 choices, dependent on air-conditioning Old air-unit from Aleph OK NO b) FFU with air-conditioning included softwall: special design • Standard FFU, • Standard softwall, • installation ? Question: air renewal inside each room ?

  4. Air-conditioning Laser specifications  +/- 1 oC HEPair Class 10,000 & +/- 0.5 oF (+/- 0.28 oC) HEPair • 208vac, 50Hz • Cooling capacity: 9050 BTU/H • Temperature: 0.6/2.0 kW • type: PID • Accuracy: +/- 0.5 oF 36cm • Condenser: • Flow rate: 1-2.5 GPM (0.3 – 0.68 m3/h) • water temperature maxi: 85 oF (29 oC) • water side pressure drop: 0.8-3.4 psi (55-234 mbar) 60cm 120cm

  5. Old air-unit from Aleph: (R.Pintus) 12kW, Chilled water air-conditioning unit.  Temperature ? ~ 6oC Control ? (PID, thermostat)… ? USC55: mixed water, 16oC for each laser enclosure Laser2 (Spare) laser3 laser1 +/- 1 oC (+/- 1 oC) +/- 1 oC

  6. Cost estimation Softwall : Solution handling, Germany 3 softwalls with special curtain ~ 12 000 € + Fan Filter Unit: + HEPair: 3 units MAC 10XL ~ 13 000 € ~ 2 200 € + + Old air-unit Cost installation & test, H4? Cost installation H4 ?