1 / 26

Data Analysis of F2 and R in Deuterium and Nuclei

Data Analysis of F2 and R in Deuterium and Nuclei. Vahe Mamyan Ibrahim Albayrak. Physics Experiment Setup HMS Detectors Calibrations Data Analysis Cross Section calculation. Hampton University. Measurement of R = s L / s T on Deuterium in the Nucleon Resonance Region.

helen-mayo
Télécharger la présentation

Data Analysis of F2 and R in Deuterium and Nuclei

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Data Analysis of F2 and R in Deuterium and Nuclei Vahe Mamyan Ibrahim Albayrak • Physics • Experiment Setup • HMS Detectors • Calibrations • Data Analysis • Cross Section calculation Hampton University

  2. Measurement of R = sL / sT on Deuterium in the Nucleon Resonance Region. Physics

  3. Transverse longitudinal mIxEd Inclusivee + d  e + X Scattering Rosenbluth Separation Technique: Where:  = flux of transversely polarized virtual photons  = relative longitudinal flux

  4. New data with high Q^2 above 3 And new epsilon points for LT separation ROSEN07 JAN05

  5. Physics • FL, F1, F2 Fundamental Structure Function Measurements on Deuterium • Structure Function Moments • Lattice QCD comparisons • Singlet and non-singlet distribution functions • Support Broad Range of Deuteron Physics • Elastic form factors • Spin structure functions • Structure functions from deuterium cross sections • BONUS neutron structure functions • Important input for neutrino physics • Quark-hadron duality studies

  6. FL can probe the gluon distributions….. • Nucleon structure composed of singlet (gluons, sea) and non-singlet (valence) distributions • At moderate x (~ 0.3), singlet comparable to non-singlet 1

  7. ∫(Fd – 2Fp)dx yields non-singlet distribution • The non-singlet moments can only be determined from differences of proton and neutron moments. • Assuming a charge-symmetric sea, n-p isolates the non-singlet • Need to pin down non-singlet (n-p) to extract singlet (FL) • OPEN QUESTION IN QCD: Do we have valence, or intrinsic, glue? Need FLd – 2FLp • “..highly precise deuteron data - due to the above aspects - • are forming a conditio sine qua non for any real precision test of QCD.” – Johannes Bluemlein

  8. Moments of the Structure Functions Mn(Q2) = ∫dxxn-2F(x,Q2) Calculated on the lattice at Q2 = 4 GeV2 Well understood in QCD Operator Product Expansion 1 0

  9. Preliminary cross section for Deuterium…

  10. Data to Monte Carlo simulation comparisons…

  11. In Conclusion… • No L/T separated resonance region (large x) data on deuterium currently • Impossible to extract high precision moments • Compare to lattice • FL to access singlet

  12. Experimental Setup HMS Detector Hut Target Scattering Chamber e´- e- Electron Beam X

  13. HMS Detectors Drift Chambers, Horizontal and vertical Electro-magnetic calorimeter Gas Cerenkov Vertically and Horizontally segmented hodoscopes

  14. Calibrations • BCM calibration • A new BCM calibration script is written based on C++/ROOT. • Drift Chamber and TOF calibration • The calibration is done by one command, just run a batch job and result is ready, quality is checked by examining the PS files produced after calibration. • Calorimeter calibration • Gas Cerenkov calibration

  15. BCM calibration

  16. BCM calibration-cont.

  17. Calorimeter calibration

  18. Gas Cerenkov calibration

  19. Data Analysis • Particle identification • Background subtraction • Acceptance calculation • Corrections • Cross section calculation

  20. Particle Identification Most background come from negative pions. Calorimeter and Gas Cerenkov are used to reject these pions. HMS P=0.44 GeV, Θ=75 degree Rejection factor is 100:1.8

  21. Background subtraction Electrons produced from charge-symmetric πo and γ production and decay are background for us. For this purpose special runs are taken with HMS at positive polarity. Since the background is charge-symmetric, it allows to count the number of positrons and subtract it from our data.

  22. Acceptance calculation • Acceptance is calculated for each Θ-W2 bin. • Number of Θ bins is fixed, 20 bins. • Size of the W bin is 0.04 GeV2.

  23. Corrections • Target boiling. • Radiative corrections.

  24. Cross Section calculation Measured CS Rad. corrected CS Bin correction factor Bin corrected cross section

  25. Cross Section • No charge symmetric background subtracted

  26. Summary • Calibrations are mostly done. • Implement charge symmetric background subtraction. • Continue data analysis

More Related