1 / 11

Jonathan Young SRWG Compliance Subgroup Chair ColumbiaGrid Planning Engineer

Jonathan Young SRWG Compliance Subgroup Chair ColumbiaGrid Planning Engineer. SRWG Update to TSS August 8, 2013 Salt Lake City, UT. Overview and Approval Items. General SRWG Topics Study Program Subgroup 2013 Study Program Annual Report Study Plan Rev 3 of Study Program Procedures

ilario
Télécharger la présentation

Jonathan Young SRWG Compliance Subgroup Chair ColumbiaGrid Planning Engineer

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Jonathan YoungSRWG Compliance Subgroup ChairColumbiaGrid Planning Engineer SRWG Update to TSS August 8, 2013 Salt Lake City, UT

  2. Overview and Approval Items • General SRWG Topics • Study Program Subgroup • 2013 Study Program Annual Report Study Plan • Rev 3 of Study Program Procedures • Exceptions List • Compliance Subgroup • Bus number requests • DPM update for Relays

  3. Base Case Status • One month behind schedule • 18-19HW2 will be first case in PSSE 33.4 • No dynamics data conversion yet • New Slack bus proposal • Existing slack will be retired • Recommendation for 24HW1 is Coulee 40296 • Evaluate 24HW1 for continued use

  4. NERC MOD B Standards

  5. 2013 Study Program Annual Report Study Plan • Follow study plan used in 2012 • Recommendation of base cases • Remaining 2012 base cases • 2013 base case through 19HS2 • Scenario case for CO/UT/N NV not available • Disturbances from survey response • 4 Cat-D disturbances from PG&E • 7 Cat-B,C,&D disturbances from PSCoarea

  6. Study Program Procedures • Redrafted Section II: Annual Study Program • General clean-up, eliminate redundancy • How do we select disturbances • How do we select base cases • Performance and representation logs • Disturbance-Performance Exceptions • Created separate document to reference • 1) Disturbances declared non-credible, 2) Performance level adjustment, 3) Less Stringent performance criteria

  7. 2012 Annual Study Report Recommendations • Examine data for models of specific gens • Nine identified • All have been examined and are in process • Colstrip ATR should be commented out of MDF

  8. Representation Log • New process started with 14HSP1 • Replog posted with each Review case • Review 14HSP1 • Approved using new data tracking process • Identify “possible” data errors • Intended to improve model, not track compliance

  9. Bus Number Requests • Reserved bus ranges for internal use • Should use 6 digit numbers going forward • New range allocated to VEA

  10. DPM Revisions for Relay Modeling • “Line and Transformer Protection • Include line and transformer three-phase relay models where TSS approved models are available. Typical relay data based on facilities of similar design and characteristics may be used to represent planned facilities. • When additional relay models have been approved by TSS, SRWG will determine appropriate implementation schedules for the necessary data required by the newly approved models” • Note: If the revision is approved, the DPM effective date would be November 2013. The 20HW1 case would be the first case that the line and transformer overcurrent three-phase relay data would be required. The tentative approval date is May 2014.

  11. Questions?