EQUIPAMENTOS DE MONITORAMENTO

EQUIPAMENTOS DE MONITORAMENTO. JORGE LUIZ N. GOUVEIA. 1. EQUIPAMENTOS DE MONITORAMENTO. DETECTOR DE GASES OXÍMETRO EXPLOSÍMETRO FOTOIONIZADOR MONITOR QUÍMICO ESPECÍFICO pH-METRO CROMATÓGRAFO À GÁS. DETECTOR DE GASES. APLICAÇÃO: INDÚSTRIA; ÁREAS DE SEGURANÇA;

ismail
Télécharger la présentation

EQUIPAMENTOS DE MONITORAMENTO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EQUIPAMENTOS DE MONITORAMENTO JORGE LUIZ N. GOUVEIA 1

  2. EQUIPAMENTOS DE MONITORAMENTO • DETECTOR DE GASES • OXÍMETRO • EXPLOSÍMETRO • FOTOIONIZADOR • MONITOR QUÍMICO ESPECÍFICO • pH-METRO • CROMATÓGRAFO À GÁS

  3. DETECTOR DE GASES • APLICAÇÃO: • INDÚSTRIA; • ÁREAS DE SEGURANÇA; • ESTUDOS PARA SAÚDE OCUPACIONAL; • ACIDENTES AMBIENTAIS.

  4. LIMITAÇÕES E CONSIDERAÇÕES • LEITURA PRÉVIA DA FOLHA DE INSTRUÇÕES • ALTAS OU BAIXAS TEMPERATURAS • UMIDADE • INTERFERÊNCIAS COM OUTRAS SUBSTÂNCIAS • VALIDADE DE 1 A 3 ANOS

  5. DETECTOR DE GASES

  6. OXÍMETRO • APLICAÇÃO: • DETERMINAR O E.P.I. APROPRIADO PARA PROTEÇÃO RESPIRATÓRIA; • IDENTIFICAR ÁREAS COM RISCO DE EXPLOSÃO; • USO ADEQUADO DE EQUIPAMENTOS DE MONITORAMENTO; • PRESENÇA DE CONTAMINANTES.

  7. LIMITAÇÕES E CONSIDERAÇÕES • ALTAS CONCENTRAÇÕES DE DIÓXIDO DE CARBONO • ALTAS OU BAIXAS TEMPERATURAS • ALTITUDE

  8. OXÍMETRO

  9. FOTOIONIZADOR • APLICAÇÃO: • POSSIBILITA A IDENTIFICAÇÃO DE ÁREAS COM ALTAS CONCENTRAÇÕES DE VAPORES TOTAIS.

  10. LIMITAÇÕES E CONSIDERAÇÕES • DETERMINAÇÃO SOMENTE DE GASES COM P.I. MENOR OU IGUAL A 11,7ev; • UMIDADE • NÃO RESPONDE A DETERMINADOS HIDROCARBONETOS DE BAIXO PESO MOLECULAR • GASES OU VAPORES TÓXICOS COM ALTO P.I.

  11. FOTOIONIZADOR

  12. ALGUMAS SUBSTÂNCIAS COM POTENCIAL DE IONIZAÇÃO MENOR DO QUE 10,6 eV • BENZENO • HEXANO • ACETATO DE BUTILA • ACETONA • TRICLOROETILENO • TOLUENO • o,m,p XILENO • ACRILATO DE METILA

  13. EXPLOSÍMETRO • APLICAÇÃO: • DETERMINAÇÃO DE GASES OU VAPORES INFLAMÁVEIS DE FORMA QUANTITATIVA.

  14. LIMITAÇÕES E CONSIDERAÇÕES • POEIRAS • UMIDADE • TEMPERATURAS EXTREMAS • INSUFICIÊNCIA DE OXIGÊNIO • COMPOSTOS DE SILICONES E SILICATOS • CHUMBO TETRAETILA • GÁSES ÁCIDOS

  15. RECOMENDAÇÕES DA US EPA PARA MONITORAMENTO DE INFLAMABILIDADE < 10 % do L.I.I - Continue a investigação com cuidado. 10 - 25 % do L.I.I - Continue a investigação com extremo cuidado, uma vez que concentrações mais elevadas podem estar presentes. > 25 %do L.I.I - Risco de Explosão. Abandone a área.

  16. EXPLOSÍMETRO

  17. MONITORES QUÍMICOS ESPECÍFICOS • MONÓXIDO DE CARBONO • GÁS CLORO • GÁS SULFÍDRICO • AMÔNIA • GÁS CIANÍDRICO

  18. MONITORES QUÍMICOS ESPECÍFICOS APLICAÇÃO: SÃO EQUIPAMENTOS ESPECÍFICOS DE ALTA PRECISÃO DESTINADOS A MONITORAMENTO PESSOAL E EM CASOS DE ATENDIMENTO A ACIDENTES AMBIENTAIS.

  19. LIMITAÇÕES E CONSIDERAÇÕES • TEMPERATURA • UMIDADE • DISPONIBILIDADE APENAS PARA ALGUMAS SUBSTÂNCIAS QUÍMICAS

  20. DETECTOR QUÍMICO ESPECÍFICO

  21. MINIGÁS 4

  22. pH METRO APLICAÇÃO: • DETERMINACÃO DA ACIDEZ OU ALCALINIDADE DE UMA SOLUÇÃO; • O pH PODE SER DETERMINADO POR COLORIMETRIA OU POR ELECTROMETRIA.

  23. LIMITAÇÕES E CONSIDERAÇÕES • ÓLEOS E GRAXAS • ERRO ALCALINO

  24. pH - METRO

  25. CROMATÓGRAFO A GÁS

  26. APLICAÇÕES • PERMITE ANÁLISE QUALITATIVA E • QUANTITATIVA EM ANÁLISES DE CAMPO • REALIZA AMOSTRAGENS PROGRAMADAS • DA CONCENTRAÇÃO DE VAPORES • ORGÂNICOS TOTAIS • REALIZA AMOSTRAGENS DE COMPOSTOS • VOLÁTEIS PRESENTES NO SOLO E ÁGUA

  27. LIMITAÇÕES E CONSIDERAÇÕES • A SENSIBILIDADE DEPENDE DOS • COMPOSTOS A SEREM DETERMINADOS, • DO MÉTODO DE AMOSTRAGEM E DO • DETECTOR ESCOLHIDO