1 / 16

Low Energy backgrounds in the TESLA IR

Low Energy backgrounds in the TESLA IR. Impact on feedback BPMs. Tony Hartin - QMUL. FONT collaboration QMUL: P Burrows, G Christian, C Clarke, G White, S Molloy. Talk Outline. Model feedback BPMs in Geant description of TESLA IR Modify Geant3 for low Energy transport

joy
Télécharger la présentation

Low Energy backgrounds in the TESLA IR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Low Energy backgrounds in the TESLA IR Impact on feedback BPMs Tony Hartin - QMUL • FONT collaboration • QMUL: P Burrows, G Christian, C Clarke, G White, S Molloy

  2. Talk Outline • Model feedback BPMs in Geant description of TESLA IR • Modify Geant3 for low Energy transport • Compare to other Monte Carlo packages (Geant4 EGS) at low energies • BPM experimental tests at SLAC ESA

  3. FONT elements - BPM • BPM provides input to beam based feedback system (see Phil’s talk) • Incident impacts on BPM affect performance BPMs sited behind masks

  4. BPM performance • 4 Copper strips in total • Noise susceptible to absorbed charge and secondary emission • 1pm error for each charge absorbed or emitted. 10e5 hits would be a problem! • low energy e-s add charge

  5. Geant 3 model • IR model adopted from Brahms • Strips placed on the wall of the beampipe • Guinea-Pig pair particles and photons tracked with different kinetic energy cuts • 4 Tesla Magnetic Field included 10 cm Cu strips

  6. BPM hits • Single 12 Gev e+ • Multiple hits through showering • Origin of hits: • Inner beampipe • Cylindrical mask • Calorimeter • 20% direct hits from IP

  7. Energy spectrum of BPM hits • Geant3 energy cuts for particle transport – default 1 MeV - minimum 10 k.e.cut • BUT.. at least half the BPM hits have k.e between 10 keV and 1 MeV • AND.. Eg e-/+ hits of just a few eV ionize BPM strips

  8. Geant3 mod for Low Energy Transport • Geant3 X-section parametrization wrong below 10kev • Recode Geant3 to parametrize real data from NEA site • Similar schemes • Apostolakis 1999, Geant4 LowE • Kippen, New Astr Rev (2004) • Y. Namito and H. Hirayama, KEK Internal 2000-4

  9. Transport Code Low E cuts • Geant3 • 1 Mev default, 10 kev min, recode to <100eV • . • LowE package available -> 250ev • EGS • KEK (low-energy)Extensions to EGS4 < 100 eV

  10. Geant 3 recoding sanity checks -Cu disc model • Fire 100 identical Incident electrons at Cu strip • Emergent flux for different E cuts • G3 mods agree with G4

  11. Geant 3 recoding sanity checks -Cu disc model • Fire 100 identical Incident electrons at Cu strip • Emergent flux for different E cuts • G3 mods agree with G4

  12. Geant3 total BPM hits - lowE • lowE mods reveal significant increase in BPM hits at 100eV cut • 6000 hits per strip per b.c NOT in the danger zone • Need to push lowE cut even lower

  13. Detector BKG (NLC) F.O.N.T. G.R.White: 13/10/2014 • Insertion of feedback system at z=4.3 m has no impact on secondary detector backgrounds arising from pair background • Past studies suggest backgrounds adversely effected only when feedback system installed forward of z=3 m

  14. Possible experimental tests at SLAC-ESA(Christian/Clarke) • Possible test of BPM performance at ESA with expected pair background at ILC – use radiator at ESA to mimic ILC pair background • 2 options – Thin target (~5-10% X0) in IR-mockup at ESA or Thick target (~30% X0) at end of linac to produce secondary spray beam in A-line • Built simple GEANT3 model for thin target option • First-step – benchmark model against EGS simulation of Keller/Woods for thin radiator

  15. Comparison of GEANT/EGS models – first results GEANT model 1 million incident electrons @25 GeV 10% X0 carbon radiator #particles E>500KeV hitting scoring plane 3m from target EGS model (Keller)

  16. Future Plans • Convert TESLA IR + feedback BPMs from Geant3 -> Geant4 • Compare low Energy performance of EGS, Geant4 and Geant3-mod • Gauge impact of crossing angle and other suggested TESLA IR mods

More Related