1 / 42

Računarske mreže

Lekcija 6. Računarske mreže. Fizički sloj. RS 232. Serijski port računara Najčešće korišćeni interfejs za umrežavanje računara u prošlosti Mogućnost direktnog povezivanja dva računara putem ovih interfejsa Asinhroni prenos podataka Maksimalna brzina je 115.200 bit/sec. RS 232. RS 232.

julius
Télécharger la présentation

Računarske mreže

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Lekcija 6 Računarske mreže Fizički sloj

  2. RS 232 • Serijski port računara • Najčešće korišćeni interfejs za umrežavanje računara u prošlosti • Mogućnost direktnog povezivanja dva računara putem ovih interfejsa • Asinhroni prenos podataka • Maksimalna brzina je 115.200 bit/sec

  3. RS 232

  4. RS 232

  5. USB • Daleko veće brzine prenosa podataka i mogućnost povezivanja više od jednog uređaja po portu • Veliki broj raličitih uređaja koji služe za umrežavanje računara (Ethernet adapteri, modemi, ISDN terminal-adapteri, ADSL modemi itd.) • Uređaji koji nisu vezani za računarske mreže (štampači, skeneri, audio-adapteri, tastature, miševi...) • Za različite uređaje nisu potrebni posebni device drivers • Za neke uređaje nije potrebno posebno napajnje

  6. USB • Broj USB uređaja:127 po jednom kontroleru • Brzina: Do 12Mbit/s (USB 1.0) Do 480 Mbit/s (USB 2.0) Do 4.8Gbit/s (USB 3.0) • Kompatibilnost unazad • Tip prenosa:Serijski • Mogućnost uključenja iisključenja “na vruće” USB Serije “A”

  7. USB • Mogućnost dodavanja spoljašnjeg USB hab-a • Maksimalno 5 nivoa dodavanja • Ukupno po jednom USB kontroleru (zajedno sa USB habo-ovima) je 127 uređaja USB Serije “A”

  8. USB • Prenos podataka ka i od uređaja je uvek jednosmeran (polu-dupleksan) • Uređaji su grupisani prema sličnim funkcijama u klase (tzv. Interfejse) • Isti drajver se može koristiti za uređaje iz iste klase • Nulta klasa se ne koristi za interfejs, već za konfiguraciju ostalih priključenih uređaja USB Serije “A”

  9. USB • Priključenje novog USB uređaja: • Reset signal do USB uređaja • Utvrđuje se brzina prenosa podataka • Računar čita SETUP informacije iz uređaja • USB kontroler uređaju dodeljuje 7-bitnu adresu • Ako je uređaj podržan od strane računara, učitava se njegov device driver i uređaj je spreman za rad • Prenos podataka se vrši tehnikom poliranja, računar polira priključene USB uređaje USB Serije “A”

  10. USB Tip A i B • Različite vrste USB konektora: • micro USB plug, • mini USB plug, • B-type plug, • A-type receptacle, • A-type plug

  11. USB • Maksimalna dužina USB kabla je 5 m (maksimalno dozvoljeno kašnjenje sa kraja na kraj je 1500 ns) • Ako je kašnjenje veće, USB kontroler neće konstatovati uređaj • Maksimalna potrošnja po uređaju ~ 100mA

  12. USB • USB signal se prenosi po dve parice istovremeno (D+ i D-) • Zavisno od standarda koriste se različiti naponi • Koristi se NRZI sistem enkodovanja podataka • Pre enkodovanja koristi se “bit stuffing” • Umetanje veštačkog 0-bita za niz koji sadrži šest uzastopnih 1-bita 1 – nema promene 0 - promena

  13. FireWire • FireWire je naziv za IEEE 1394 High Speed Serial Bus (nazvan od strane Aple-a) • Serijski prenos podataka visokih performansi • Manje popularan od USB-a ali postoji priličan broj uređaja koji ga koristi za povezivanje sa računarom (npr. Digitalne video kamere, industrijski sistemi, profesionalni audio sistemi i sl.) 4-pin (left) and 6-pin (right) FireWire 400 connectors

  14. FireWire • Mogućnost povezivanja do 63 uređaja • Dozvoljen je DMA pristup • Dozvoljava peer-to-peer komunikaciju • npr. Komunikacija između skenera i štampača, bez korišćenja RAM memorije • Podržava potrošnju od 45 W

  15. FireWire • FireWire 400 (IEEE 1394a) • 6 pinski • Brzina prenosa podataka između uređaja 100, 200, ili 400 Mbit/s • Dužina kabla 4,5 m • FireWire 800 (IEEE 1394b) • 9 pinski • Brzina prenosa podataka 800 Mbit/s, kompatibilan sa prethodnim standardom • Specifikacija podržava optičke veze, dužine do 100 m, i brzine do 3.2 Gbit/s

  16. USB vs. FireWire • USB 5 V, FireWire 30 V • FireWire je brži • FireWire ima jače performanse i namenjen je za vremenski osetljive aplikacije (audio i video) • USB je hardverski jednostavniji i manje košta

  17. IrDA • Infrared Data Association • Infrared način prenosa podataka podrazumeva infracrvene zrake kao nosioce komunikacije • Potreba za optičkom vidljivošću i preciznim usmerenjem svetlosti; mala brzina prenosa podataka • Koristi se za premošćenje malih udaljenosti, a ovim adapterima su uglavnom opremljeni • mobilni telefoni, • lap-top računari i • PDA uređaji

  18. IrDA • Rastojanje (standardno 1 m) • Brzina prenosa podataka: 2,4Kbit/s do 16 Mbit/s • Prenos signala u baseband-u • Polu-dupleksni prenos (full-duplex nije moguć)

  19. Bluetooth • Bluetooth je bežična tehnologija povezivanja uređaja na kratkim rastojanjima koja primenjuje male snage zračenja • Bežične PAN mreže • Dizajnirana je kao zamena za kablovske sisteme povezivanja, kao i druge tehnologije kratkog dometa • Personalno okruženje u radijusu do 10 metara • Povezivanje mobilnih telefona, notebook računara, PC-a, štampača, GPS prijemnika, digitalnih kamera itd.

  20. Bluetooth • Bluetooth je “ad-hoc” mreža, ne postoji mrežna infrastruktura • Koristi se posebna modulaciona tehnika, različita od tehnike kod Wi-Fi mreža (a isti je frekvencijski opseg) • Frekvencijski opseg za prenos je u granicama 2.4 GHz do 2.48 GHz, više kanala širine 1 MHz, frekvencijsko skakanje • Teorijska najveća moguća brzina prenosa po Bluetooth specifikaciji 2.0 iznosi 2.1 Mb/s. • Razlike u odnosu na Wi-Fi • Wi-Fi zahteva konfiguraciju set-up-a, • Veća rastojanja • Bolja zaštita

  21. P P P P P M M Master device Slave device Parked device (inactive) S S S S Bluetooth • Domet ≤10 m • Zamena za kablove (miš, tastatura, ...) • ad hoc: nema posebne infrastrukture • master/slaves: • slaves request permission to send (to master) • master grants requests radius of coverage

  22. Bluetooth • Bluetooth adapter • Integrisan • Eksterni – dongl • Jedan adapter se koristi za različite uređaje • Ne zahteva se optička vidljivost, uređaji mogu biti u različitim prostorijama • IEEE 802.15 – Wireless PAN • 802.15.1 – Wireless PAN Bluetooth, fizički nivo i MAC podsloj

  23. Bluetooth • Master Bluetooth uređaj može da komunicira sa 7 Slave uređaja – čine pikonet • Uloge master-slave se menjaju u vremenu • Dva ili više pikoneta se mogu udružiti u scatternet • Uspostava konekcije: • Device name • Device class • List of services • Technical information: device features, manufacturer, Bluetooth specification used, clock offset • Zaštita komunikacija:autentikacija, poverljivost, na bazi PIN-a, blokovski algoritam

  24. Bluetooth

  25. Bluetooth

  26. Ethernet • Najviše korišćena mrežna tehnologija u LAN mrežama • IEEE je uveo 1983. godine službeni standard za Ethernet i nazvao ga IEEE 802.3 • Fizički nivo • MAC podsloj/Data Link Layer • Format za adresiranje • Prednosti Ethernet mreža su: • mreže su jednostavne za planiranje i ekonomične za instalaciju; • mrežne komponente su jeftine; • tehnologija se pokazala kao pouzdana; • jednostavno je dodati i ukloniti računare sa mreže; • podržavaju ga mnogi softverski i hardverski sistemi.

  27. Ethernet • Nastao je iz koncepta slanja u “ether” • Prve mreže su koncipirane oko koaksijalnih kablova • Korisnici se takmiče za pristup mreži i nema garancije da će korisnik moći da pristupi mreži uvek kada ima podataka za slanje (CSMA/CD) • Do problema dolazi kada dva ili više korisnika želi da koristi mrežu u isto vreme • U tom slučaju dolazi do sudara (kolizije) podataka različitih korisnika • Korisnici mora da prestanu sa slanjem i da sačekaju određeno vreme dok mreža ne postane slobodna

  28. Ethernet • Ethernet sam po sebi ne obezbeđuje nikakvu sigurnost, on je jednostavan i otvorena fizička sredina za prenos podataka. • Nije imun na prisluškivanje i špijuniranje • Slabosti Etherneta su: • Otvorena arhitektura gde svaki čvor može da šalje ili da prima; • koristi širokodifuzne (broadcast) komunikacije; • lako ga je prisluškivati; • nema nikakav hardver za obezbeđenje; • lako je onesposobiti mrežu • Promene: od Etherneta za koaksijalni kabl do Gb Etherneta • Broadcast komunikacija - nekada • Point- to-point komunikacija - danas

  29. Ethernet • Postoje nekoliko glavnih standardnih tipova Etherneta: • standardni, ili sa debelim kablom (thickwire) Ethernet (10BASE5) • sa tankim kablom, thinnet (ili thinwire) Ethernet ili Cheapernet (10BASE5) • Ethernet sa upredenim paricama (10BASET) • Ethernet sa optičkim kablovima (10BASEFL) • Brzi Ethernet (100BASETX ili 100VGAnyLAN) • Gigabitni Ethernet (1000BASET ili 1000BASE SX, CX, LX) • 10 Gb Ethernet (10BASE SW, LW, EW)

  30. Ethernet • Ethernet okvir - tipično

  31. Wi-Fi (802.11) • Bežično (wireless) umrežavanje - najjednostavniji način umrežavanja, nudi srednju brzinu i ne zahteva dodatne kablove • Sa WiFi karticama (interna ili eksterna) i dogovarajućim antenama, moguće je formirati manje mreže (mreže do 30 m) • Za veća rastojanja koriste se eksterne antene koje vrše dodatno pojačanje signala • Ako je mreža osigurana ona će tražiti WEP ili noviji WPA (2) ključ, a ako je slobodna onda nema nikakvih ograničenja za spajanje

  32. network infrastructure Wi-Fi (802.11) wireless link • Tipično se koristi za povezivanje mobilnih korisnika na bazbu stanicu • multiple access protocol upravlja pristupom mreži • Različite brzine prenosa podataka i rastojanja

  33. Wi-Fi (802.11) • Wireless Acces Point – hotspot • Nudi pokrivenost od oko 30 metara • Objedinjava wireless uređaje u jednu tačku, povezanu na žični LAN • Najskuplja varijanta je: Wireless Access Point Router koji sadrži priključak za DSL modem, Router, Ethernet Hub, Firewall i Access Point

  34. Wi-Fi (802.11) • Standardi Wi-Fi: • 802.11a standard ima teoretsku brzinu od 54 Mbit/s, najčešće ona iznosi oko 30 Mbit/s, radi na 5 GHz • 802.11b, brzina prenosa je do 11 Mbit/s, ali uz velike prepreke i smetnje brzina može spasti na malih 1 do 2 Mbit/s, najjeftinija varijanta WiFi mreže, radi na 2,4 GHz • 802.11g je predstavljen 2003. godine i objedinio je prethodna dva standarda. Radi na 2.4 GHz, ali ima skoro istu brzinu kao i 802.11a standard

  35. Outdoor 50 – 200m Mid range outdoor 200m – 4Km Long range outdoor 5Km – 20Km Indoor 10 – 30m Wi-Fi (802.11) 54 Mbps 802.11{a,g} 5-11 Mbps .11 p-to-p link 802.11b 1 Mbps 802.15 3G 384 Kbps UMTS/WCDMA, CDMA2000 2G 56 Kbps IS-95 CDMA, GSM

  36. ISDN • Integrated Services Digital Network • Obezbeđuje digitalnu vezu između korisničkih mrežnih interfejsa • ISDN predstavlja nadgradnju, odnosno viši stepen postojeće javne komutirane telefonske mreže • Veći deo komutacionih sistema (telefonskih centrala) i prenosnih sistema između centrala je digitalizovan. • Međutim, pretplatnički deo mreže je ostao analogan

  37. ISDN • Uvođenjem ISDN-a i pretplatnički deo mreže postaje digitalan, i to korišćenjem postojećih bakarnih parica

  38. ISDN • Postoje dva tipa ISDN pristupa: • Bazni (BRI – Basic Rate Interface) • Dva B kanala (prenos informacija) od po 64 kbit/s • Jedan D kanal (sinhronizacija i korisnička signalizacija) od 16 kbit/s, • Ukupna brzina: 144 kbit/s • Namenjen za kućne korisnike • Primarni (PRI – Primary Rate Interface) • Trideset B kanala protoka 64kbit/s za govor i prenos podataka • Jedan D kanal protoka 64kbit/s za sinhronizaciju, signalizaciju i prenos podataka • Ukupna brzina: 2Mbit/s • Namenjen za poslovne korisnike

  39. ISDN • Na ISDN liniju se mogu priključiti različiti terminalni uređaji: • ISDN telefon • Terminalni adapter (TA) za priključenje postojećih analognih uređaja • ISDN kartice (za prenos podataka potrebna je ISDN kartica u računaru ili eksterni ISDN adapter) • ISDN LAN router ili bridge • ISDN multiplekseri • ISDN PABX – pretplatničke (kućne) centrale ISDN tipa

  40. xDSL • Digital Subscriber Line • Brzine prenosa: od 144 kb/s do 50 Mb/s • Najčešće u upotrebi: ADSL-Asymetric Digital Subscriber Line • Usluga je bazirana na stalnom i brzom pristupu Internetu po već postojećoj telefonskoj liniji (parici) bez njenog zauzeća ili promene telefonskog broja • Brzina prenosa je od 256/64 Kb/s do 768/192 Kb/s za download i upload

  41. ADSL

  42. Fizički sloj Pitanja ?

More Related